ANUNCIAR
1SCA022401R4910 ABB OTP63B4M Enclosed switch View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SCA022401R4910 ABB OTP63B4M Enclosed switch

1SCA022401R4910

ABB

OTP63B4M Enclosed switch

Int. Disconnector in OTP63B4M box

OTP63B4M Enclosed Switch Disconnector

More details


Low-voltage industrial components > Switch disconnector

Manual Switches > Box

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $158.25
Unit price: $158.25
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SCC340076D0201
RoHS Declaration1SCC340075D0201
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP199e95dd-0ebf-4fe4-9d83-3e24fdc6e7ce Finland
Simplified SCIP31da8d5e-f6c5-46a7-8a84-df46f95f1c61 Germany
30bc1be6-52b5-4a7f-9edd-b7f98f3dc45f Netherlands
0b37920f-a589-43a5-afa9-6e238c412ff7 Portugal
b39cb493-bbbc-457d-bb00-c8de2c34320f Bulgaria
f5337b41-dd97-44af-8501-a92956ab524e Sweden
d51a118e-5e27-4fc2-b480-f44894eea927 Sweden
7d741f4b-29f1-4c66-9349-fe25b80a0c80 France
51f3db1c-d781-4ee5-9947-e485a66896dd Germany
c32b2d05-cf51-4161-a799-b3f4b32b9abe Germany
be421aad-660d-45a7-8cf9-bdb7b3799c74 France
194d088e-7b98-4fda-b8a0-86e3c5d974ed Greece
c8a1a07e-416e-4937-9166-d651bf4c944d Italy
575bf042-a340-43ae-a4be-cf1ba80d2fc0 Poland
8ff61f39-f8b0-4837-a600-2de1f762dd67 Spain
e43e2654-85a8-4515-95c6-1e94af3f0507 Belgium
3cfab625-571a-4d7a-a104-b04bc9698457 Poland
02e20e6a-b59d-4efc-b478-44452ebfd453 Norway
1757c807-ec25-4309-976c-da91b3cf952d Hungary
726c8e3c-2322-4fd5-8351-e154df04b9f4 Belgium
96ac79e6-5abf-4c5b-8b28-bbfb4377323f Estonia
1b7aa194-6052-4be8-a718-0874fcab0486 Poland
a5dcfa0c-fb3f-4f39-8a6e-dfeb1728f7df Hungary
a02bf7bf-f070-4130-9352-712f59d447a3 Croatia
472ac75a-8f5b-4782-b9de-a7bfa2a0b3bf Germany
446fa673-0167-470c-a965-c1da06ce789d Denmark
14594d71-42ec-43db-b8a4-d7d27c4a60fd Germany
fb731b89-e38b-426b-8dab-007a826502d0 Czech Republic
Toxic Substances Control Act - TSCA1SCC340095D0201
Popular Downloads
Data Sheet, Technical Information1SCC340015C0201
Instructions and Manuals1SCC340002M0012
Mechanical DrawingsOTPK201490SM32.stp
Environmental
Degree of Protectionacc. to IEC 60529 IP65
Pollution Degree3
Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85363030
Last Ordering Date2026-08-31 All Countries
Replacement Product ID (NEW)OTP63GB4M
Country or Territory of OriginFinland
Dimensions
Product Net Width145 mm
Product Net Height200 mm
Product Net Depth / Length90 mm
Product Net Weight0.9 kg
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width162 mm
Package Level 1 Depth / Length222 mm
Package Level 1 Height148 mm
Package Level 1 Gross Weight1 kg
Package Level 1 EAN6417019131344
Technical
Cable Cross-Section1.5 ... 35 mm²
Cable Entry PositionTop and/or Bottom
Cable Outlets Per Side2xM32+M16 / 2xM32+M16
Connecting Capacity Main CircuitScrew Clamp 1.5 ... 35 mm²
Screw Clamp / PE Terminal 2pc,1.5 ... 35 mm²
Conventional Thermal Current (Ithe)Fully Enclosed 80 A
Degree of Protectionacc. to IEC 60529 IP65
Enclosure MaterialPlastic
Handle ColorBlack
Handle TypeSelector handle
Impact Resistance RatingHousing IK08
Maximum Mounted Auxiliary Contacts2 NO, 2 NC
Mounted Auxiliary Contacts0 NO, 0 NC
Neutral TypeFixed and Switchable Neutral
Number of Auxiliary Contacts NC0
Number of Auxiliary Contacts NO0
Number of Poles4P
Pollution Degree3
Position of Line TerminalsTop In - Bottom Out
Position of Neutral TerminalsTop In - Bottom Out
Position of PE TerminalsTop In - Bottom Out
Power Lossat Rated Operating Conditions per Pole 4.5 W
Rated Impulse Withstand Voltage (Uimp)1.5 kV
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 750 V
Rated Operational Current AC-21A (Ie)(500 V) 80 A
(380 ... 415 V) 80 A
(690 V) 80 A
Rated Operational Current AC-22A (Ie)(380 ... 415 V) 80 A
(690 V) 80 A
Rated Operational Current AC-23A (Ie)(380 ... 415 V) 75 A
(500 V) 58 A
(690 V) 20 A
Rated Operational Power AC-23A (Pe)(380 ... 415 V) 37 kW
(500 V) 37 kW
(690 V) 18.5 kW
Rated Operational VoltageMain Circuit 750 V
Rated Short-Circuit Making Capacity (Icm)(690 V AC) 2.1 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 1.5 kA
Recommended Screw DriverMain Circuit Pozidriv 2
StandardsIEC 60947-1, -3
Tightening TorqueMain Circuit 2 N·m
Wire Stripping Length13 mm
Technical UL/CSA
Wire Stripping Length13 mm
Recommended Screw DriverMain Circuit Pozidriv 2
Tightening TorqueMain Circuit 2 N·m
Certificates and Declarations
BV Certificate1SCC340018D0204
Declaration of Conformity - CE1SCC340003D2704
DNV GL Certificate1SCC340045D0203
External Classifications and Standards
Object Classification CodeQ
ETIM 9EC000216 - Switch disconnector (low voltage)
ETIM 10EC000216 - Switch disconnector (AC)
UNSPSC39122205
IDEA Granular Category Code (IGCC)5166 >> Safety switch
eClassV11.1 : 27371403
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)

ETIM for 1SCA022401R4910 Low-voltage industrial controls and switchgear (EC000216)
Feature Name Feature Value
Version as main switch (EF006981) Yes
Version as maintenance-/service switch (EF006986) Yes
Version as safety switch (EF006985) No
Version as emergency stop installation (EF006959) No
Version as reversing switch (EF009408) No
Number of switches (EF005586) 1
Max. rated operation voltage Ue AC (EF007355) 750 V
Rated operating voltage (EF001435) 750 V
Rated permanent current Iu (EF001389) 80 A
Rated permanent current at AC-23, 400 V (EF011777) 75 A
Rated permanent current at AC-21, 400 V (EF009165) 80 A
Rated short-time withstand current lcw (EF007050) 1.5 kA
Rated operation power at AC-23, 400 V (EF007027) 37 kW
Switching power at 400 V (EF009166) 37 kW
Number of poles (EF001391) 4
Number of auxiliary contacts as normally closed contact (EF001377) 0
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as change-over contact (EF003531) 0
Motor drive optional (EF007386) No
Motor drive integrated (EF006697) No
Voltage release optional (EF007491) No
Device construction (EF008240) Complete device in housing
Suitable for front mounting 4-hole (EF007247) No
Suitable for front mounting centre (EF007248) No
Suitable for distribution board installation (EF007262) Yes
Colour control element (EF007167) Black
Type of control element (EF006976) Long turning handle
Interlockable (EF006281) Yes
Degree of protection (IP), front side (EF003118) IP65
Degree of protection (NEMA) (EF011959) Other

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.