| Circular Value | |
|---|---|
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Environmental Information | 1SCC301262D0201 |
| Environmental Product Declaration - EPD | 1SCC301278D0201 |
| REACH Declaration | 1SCC011021D0201 |
| RoHS Information | 1SCC011020D0201 |
| Toxic Substances Control Act - TSCA | 1SCC011025D0201 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 1SCC301278D0201 |
| Ordering | |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85365080 |
| Country of Origin | Finland (FI) |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SCC301020C0201 |
| Instructions and Manuals | 1SCC301055M0003 |
| Mechanical Drawings | 1SCC301442F0001 |
| 1SCC301441F0001 | |
| OT16-40F6.igs | |
| Environmental Product Declaration - EPD | 1SCC301278D0201 |
| Dimensions | |
| Product Net Width | 70 mm |
| Product Net Height | 68 mm |
| Product Net Depth / Length | 68 mm |
| Product Net Weight | 0.21 kg |
| Technical | |
| Rated Operational Current AC-21A (Ie) | (380 ... 415 V) 16 A |
| (500 V) 16 A | |
| (690 V) 16 A | |
| Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 16 A |
| (500 V) 16 A | |
| (690 V) 16 A | |
| Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 16 A |
| (500 V) 16 A | |
| (690 V) 10 A | |
| Rated Operational Power AC-23A (Pe) | (220 ... 240 V) 3 kW |
| (400 ... 415 V) 7.5 kW | |
| (500 V) 7.5 kW | |
| (690 V) 7.5 kW | |
| Conventional Free-air Thermal Current (Ith) | Θ = 40 °C 25 A |
| Conventional Thermal Current (Ithe) | Fully Enclosed 25 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 750 V |
| Rated Operational Voltage | Main Circuit 750 V |
| Rated Short-Circuit Making Capacity (Icm) | (690 V) 0.71 kA |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 0.5 kA |
| Rated Conditional Short-Circuit Current (Inc) | (40 A fuse, ≤415V) 50 kA |
| (25 A fuse, 690 V) 50 kA | |
| Power Loss | at Rated Operating Conditions per Pole 0.3 W |
| Pollution Degree | 3 |
| Handle Type | Knob |
| Handle and shaft not included | |
| Switches Operating Mechanism | Mechanism on Top of the Switch |
| Distance Between Phases | Standard |
| Position of Line Terminals | Top In - Bottom Out |
| Bottom In - Top Out | |
| Operating Mode | Front operated |
| Standards | IEC 60947-3 / UL 508 / CSA C22.2 No. 14 |
| Special Functions | No |
| Mounting Type | Base mounting |
| Number of Poles | 6 |
| Cable Cross-Section | Cu 0.75 ... 10 mm² |
| Degree of Protection | Front IP20 |
| Terminal Type | Screw Terminals |
| Tightening Torque | acc. IEC 60947-1 0.8 N·m |
| Mechanical Durability | 20000 |
| Lock Type | No |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | 600 V |
| Ampere Rating | 20 A |
| Horsepower Rating UL/CSA | (110 ... 120 V AC) Single Phase 1 Hp |
| (240 V AC) Single Phase 2 Hp | |
| (440 ... 480 V AC) Single Phase 5 Hp | |
| (550 ... 600 V AC) Single Phase 7.5 Hp | |
| (220 ... 240 V AC) Three Phase 5 Hp | |
| (440 ... 480 V AC) Three Phase 10 Hp | |
| (550 ... 600 V AC) Three Phase 10 Hp | |
| Tightening Torque | acc. IEC 60947-1 0.8 N·m |
| Tightening Torque UL/CSA | 7 in·lb |
| Environmental | |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Environmental Information | 1SCC301262D0201 |
| Toxic Substances Control Act - TSCA | 1SCC011025D0201 |
| Certificates and Declarations | |
| A2L Certificate – IEC | 1SCC301335D0201 |
| ATEX Certificate | No certification needed |
| Declaration of Conformity - CE | 1SCC301166D2703 |
| REACH Declaration | 1SCC011021D0201 |
| UL Certificate | cULus certificate OT16-80 |
| VDE Certificate | No certification needed |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 80 mm |
| Package Level 1 Depth / Length | 112 mm |
| Package Level 1 Height | 80 mm |
| Package Level 1 Gross Weight | 0.25 kg |
| Package Level 1 EAN | 6417019389783 |
| Classifications | |
| Object Classification Code | Q |
| ETIM 7 | EC000216 - Switch disconnector |
| ETIM 8 | EC000216 - Switch disconnector |
| ETIM 9 | EC000216 - Switch disconnector (low voltage) |
| UNSPSC | 39122233 |
| IDEA Granular Category Code (IGCC) | 5290 >> Disconnect switch |
| eClass | V11.1 : 27371403 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| E-Number (Finland) | 3601424 |
| E-Number (Sweden) | 3172087 |
| Feature Name | Feature Value |
|---|---|
| Version as main switch (EF006981) | Yes |
| Version as maintenance-/service switch (EF006986) | Yes |
| Version as safety switch (EF006985) | No |
| Version as emergency stop installation (EF006959) | No |
| Version as reversing switch (EF009408) | No |
| Number of switches (EF005586) | 1 |
| Max. rated operation voltage Ue AC (EF007355) | 750 V |
| Rated operating voltage (EF001435) | 750 V |
| Rated permanent current Iu (EF001389) | 25 A |
| Rated permanent current at AC-23, 400 V (EF011777) | 16 A |
| Rated permanent current at AC-21, 400 V (EF009165) | 16 A |
| Rated short-time withstand current lcw (EF007050) | 0.5 kA |
| Rated operation power at AC-23, 400 V (EF007027) | 7.5 kW |
| Switching power at 400 V (EF009166) | 7.5 kW |
| Number of poles (EF001391) | 6 |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| Motor drive optional (EF007386) | No |
| Motor drive integrated (EF006697) | No |
| Voltage release optional (EF007491) | No |
| Device construction (EF008240) | Complete device in housing |
| Suitable for front mounting 4-hole (EF007247) | No |
| Suitable for front mounting centre (EF007248) | No |
| Suitable for distribution board installation (EF007262) | Yes |
| Type of control element (EF006976) | Long turning handle |
| Interlockable (EF006281) | No |
| Type of electrical connection of main circuit (EF006819) | Screw connection |
| Degree of protection (IP), front side (EF003118) | IP20 |
| Degree of protection (NEMA) (EF011959) | Other |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG TRANSFER SWITCHES 2023 EN.pdf | 42 Mbytes |
|
| OT16F6 switch-disconnector - ABB - OT16F6 - 1SCA104834R1001 | 91 Kbytes |
![]() |
| OT16F6 1SCA104834R1001 ABB OT16F6 switch-disconnector | 79 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.