MS496-63 1SAM570000R1007 ABB MS496-63 Manual Motor Starter View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MS496-63 1SAM570000R1007 ABB MS496-63 Manual Motor Starter

MS496-63

1SAM570000R1007

ABB

MS496-63 Manual Motor Starter

MS496-63 Manual Motor Starter 45 ... 63 A

More details


Electronic motor protection relays

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85362010
Popular Downloads
Data Sheet, Technical Information1SBC100173C0201
Data Sheet, Technical Information (Part 3)9AKK105713A1103
Instructions and Manuals1SAM507001R1001
Time-Current Characteristic Curve1SAM500502F0007
Dimensions
Product Net Width70 mm
Product Net Height165 mm
Product Net Depth / Length174 mm
Product Net Weight2.278 kg
Technical
Rated Service Short-Circuit Breaking Capacity (Ics)(230 V AC) 100 kA
(400 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 7.5 kA
(690 V AC) 4 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 70 kA
(500 V AC) 15 kA
(690 V AC) 7.5 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)819 A
Setting Range45 ... 63 A
Rated Operational Power AC-3 (Pe)(400 V) Three Phase 30 kW
Rated Operational VoltageMain Circuit 690 V AC
Main Circuit 450 V DC
Rated Operational Current (Ie)63 A
Rated Operational Current AC-3 (Ie)63 A
Rated Frequency (f)Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)Main Circuit 6 kV
Rated Insulation Voltage (Ui)690 V
Power Lossat Rated Operating Conditions per Pole 2.8 ... 5.6 W
Number of Poles3P
Conventional Free-air Thermal Current (Ith)Main Circuit 63 A
Degree of ProtectionHousing IP20
Main Circuit Terminals IP00
Pollution Degree3
Electrical Durability25000 cycle
Mechanical DurabilityNr. Operations 50000 cycle
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1x 2.5 ... 50 mm²
Flexible with Ferrule 2x 2.5 ... 35 mm²
Solid 1/2x 2.5 ... 16 mm²
Stranded 1x 10 ... 70 mm²
Stranded 2x 10 ... 50 mm²
Tightening TorqueMain Circuit 4 ... 6 N·m
Wire Stripping LengthMain Circuit 17 mm
Recommended Screw DriverHexagon 4
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Actuator TypeRotary Handle
Contact Position IndicationON / OFF / TRIP
StandardsCSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 508
Technical UL/CSA
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Horsepower Rating UL/CSA(200 V AC) Three Phase 20 Hp
(208 V AC) Three Phase 20 Hp
(220 ... 240 V AC) Three Phase 25 Hp
(440 ... 480 V AC) Three Phase 50 Hp
(550 ... 600 V AC) Three Phase 60 Hp
General Use Rating UL/CSA(600 V AC) 63 A
Connecting Capacity Main Circuit UL/CSAFlexible 1x 10-2/0 AWG
Flexible 1/2x 10-1/0 AWG
Stranded 1x 10-2/0 AWG
Stranded 1/2x 10-1/0 AWG
Tightening Torque UL/CSAMain Circuit 35 ... 53 in·lb
Environmental
Ambient Air TemperatureOperation -20 ... +70 °C
Operation Compensated -20 ... +60 °C
Storage -50 ... +80 °C
Ambient Air Temperature CompensationYes
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 25g
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
RoHS Declaration1SAA918002-4401
RoHS InformationFollowing EU Directive 2002/95/EC August 18, 2005 and amendment
Toxic Substances Control Act - TSCA2CMT2023-006539
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
BV Certificate1SAA937000-0201
CQC CertificateCQC2013010307604042
cUL CertificatecUL_E195536
Declaration of Conformity - CCC2022960307001586
Declaration of Conformity - CE1SAD938502-0050
Declaration of Conformity - UKCA1SAD938500-1051
DNV Certificate1SAA937000-0302
EAC Certificate1SAA937001-2703
GL Certificate1SAA937000-0403
LR Certificate1SAA937000-0504
RMRS Certificate1SAA918000-0704
UL CertificateUL_E167205
UL_E195536
Container Information
Package Level 1 Unitscarton 1 piece
Package Level 1 Width76.5 mm
Package Level 1 Depth / Length190 mm
Package Level 1 Height171 mm
Package Level 1 Gross Weight2.3 kg
Package Level 1 EAN4013614265532
External Classifications and Standards
Object Classification CodeF
ETIM 9EC000074 - Motor protection circuit-breaker
ETIM 10EC000074 - Motor protection circuit-breaker
eClassV11.0 : 27370401
UNSPSC39121521
IDEA Granular Category Code (IGCC)4845 >> 3 Pole Motor Circuit Protector Circuit Breakers

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.