Product successfully added to your shopping cart
1SAM451000R1014
ABB
1
MS165-32 Manual Motor Starter
MS165-32 MOTOR GUARD REG. 23-32A
MS165-32 Manual Motor Starter 23 ... 32 A
Low-voltage industrial components > Motor protection circuit-breaker
Electronic motor protection relays > Electronic motor protection relays Mx116 and Mx132
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362010 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC131083D0201 |
| Instructions and Manuals | 2CDC131081M6801 |
| Instructions and Manuals (Part 2) | 2CDC131060M0202 |
| Ex Operating Instructions | 2CDC131087M6801 |
| Time-Current Characteristic Curve | 1SAM400505F0004 |
| I²t Characteristic | 1SAM400506F0001 |
| Cut-off Current Characteristic | 1SAM400507F0001 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimension Diagram | 1SAM400401F0001 |
| Dimensions | |
| Product Net Width | 55 mm |
| Product Net Height | 142.65 mm |
| Product Net Depth / Length | 122.1 mm |
| Product Net Weight | 0.97 kg |
| Technical | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (230 V AC) 100 kA |
| (250 V DC) 3 Poles in Series 100 kA | |
| (400 V AC) 100 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 30 kA | |
| (690 V AC) 10 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V AC) 100 kA |
| (250 V DC) 100 kA | |
| (400 V AC) 100 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 30 kA | |
| (690 V AC) 10 kA | |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 480 A |
| Setting Range | 23 ... 32 A |
| Rated Operational Power AC-3 (Pe) | (400 V) Three Phase 15 kW |
| Rated Operational Power AC-3e (Pe) | (400 V) Three Phase 15 kW |
| Rated Operational Voltage | Main Circuit 690 V AC |
| Main Circuit 250 V DC | |
| Rated Operational Current (Ie) | 32 A |
| Rated Operational Current AC-3 (Ie) | 32 A |
| Rated Operational Current AC-3e (Ie) | 32 A |
| Rated Operational Current DC-5 (Ie) | 32 A |
| Rated Frequency (f) | Main Circuit 50 Hz |
| Main Circuit 60 Hz | |
| Operating Frequency (fsw) | 0 ... 415 Hz |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Power Loss | at Rated Operating Conditions per Pole 2.27 ... 4.40 W |
| Number of Poles | 3P |
| Conventional Free-air Thermal Current (Ith) | Main Circuit 32 A |
| Degree of Protection | Housing IP20 |
| Main Circuit Terminals IP10 | |
| Pollution Degree | 3 |
| Electrical Durability | 25000 cycle |
| Mechanical Durability | Nr. Operations 50000 cycle |
| Terminal Type | Screw Terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 1 ... 35 mm² |
| Flexible with Insulated Ferrule 1/2x 1 ... 35 mm² | |
| Flexible 1/2x 1 ... 35 mm² | |
| Rigid 1/2x 1 ... 4 mm² | |
| Solid 1/2x 1 ... 4 mm² | |
| Stranded 1/2x 1 ... 50 mm² | |
| Tightening Torque | Main Circuit 4 N·m |
| Wire Stripping Length | Main Circuit 16 mm |
| Recommended Screw Driver | Pozidriv 2 |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Minimum Mounting Distance | Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm |
| Electrical Conductive Board, Horizontal - Up to 400 V 0 mm | |
| Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm | |
| Electrical Conductive Board, Vertical 75 mm | |
| Other Device Same Type, Horizontal 0 mm | |
| Other Device Same Type, Vertical 150 mm | |
| Actuator Type | Rotary Handle |
| Contact Position Indication | ON / OFF / TRIP |
| Standards | CSA 22.2 No. 14 |
| IEC/EN 60947-1 | |
| IEC/EN 60947-2 | |
| IEC/EN 60947-4-1 | |
| UL 60947-4-1 | |
| Technical UL/CSA | |
| Short-Circuit Current Rating (SCCR) | Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA |
| Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| Horsepower Rating UL/CSA | (200 V AC) Three Phase 7.5 Hp |
| (208 V AC) Three Phase 10 Hp | |
| (220 ... 240 V AC) Three Phase 10 Hp | |
| (440 ... 480 V AC) Three Phase 20 Hp | |
| (550 ... 600 V AC) Three Phase 30 Hp | |
| Full Load Amps Motor Use | (200 V AC) Three Phase 25.3 A |
| (208 V AC) Three Phase 30.8 A | |
| (220 ... 240 V AC) Three Phase 28 A | |
| (440 ... 480 V AC) Three Phase 27 A | |
| (550 ... 600 V AC) Three Phase 32 A | |
| Locked Rotor Amps | (200 V AC) Three Phase 146 A |
| (208 V AC) Three Phase 179 A | |
| (220 ... 240 V AC) Three Phase 162 A | |
| (440 ... 480 V AC) Three Phase 145 A | |
| (550 ... 600 V AC) Three Phase 174 A | |
| General Use Rating UL/CSA | (600 V AC) 32 A |
| Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 16-0 AWG |
| Stranded 1/2x 16-0 AWG | |
| Tightening Torque UL/CSA | Main Circuit 35 in·lb |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +70 °C |
| Operation Compensated -25 ... +60 °C | |
| Storage -50 ... +80 °C | |
| Ambient Air Temperature Compensation | Yes |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 25g |
| Resistance to Vibrations | Mounted on Mounting Plate: 5g 3 ... 150 Hz |
| Mounted on DIN-Rail: 4g 3 ... 150 Hz | |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SAA963005-4502 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006539 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| End Of Life Disassembling Instructions | 1SAC200284H0001 |
| Environmental Product Declaration - EPD | 1SAC200253H0001 |
| Certificates and Declarations | |
| ABS Certificate | 1SAA963002-0101 |
| ATEX Certificate | 1SAA918001-3901 |
| BV Certificate | 1SAA963002-0201 |
| CB Certificate | 1SAA918002-2002 |
| CCC Certificate | 2024010307654703 |
| CQC Certificate | CQC2015010307760141 |
| Cut-off Current Characteristic | 1SAM400507F0001 |
| Declaration of Conformity - CCC | 2020980307003042 |
| Declaration of Conformity - CE | 1SAD101100-3408 |
| Declaration of Conformity - UKCA | 1SAD201100-3408 |
| DNV GL Certificate | 1SAA963002-0301 |
| EAC Certificate | 1SAA963000-2701 |
| IECEx Certificate | 1SAA918000-4001 |
| KC Certificate | 1SAA963001-1501 |
| LR Certificate | 1SAA918001-0501 |
| RMRS Certificate | 1SAA918000-0704 |
| UL Certificate | E137861-20150206 |
| E345003-20150206 | |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 64 mm |
| Package Level 1 Depth / Length | 177 mm |
| Package Level 1 Height | 140 mm |
| Package Level 1 Gross Weight | 1.1 kg |
| Package Level 1 EAN | 4013614486081 |
| Package Level 2 Units | carton 12 piece |
| Package Level 2 Width | 330 mm |
| Package Level 2 Depth / Length | 400 mm |
| Package Level 2 Height | 320 mm |
| Package Level 2 Gross Weight | 13 kg |
| Package Level 2 EAN | 4013614503948 |
| External Classifications and Standards | |
| Object Classification Code | F |
| ETIM 9 | EC000074 - Motor protection circuit-breaker |
| ETIM 10 | EC000074 - Motor protection circuit-breaker |
| eClass | V11.0 : 27370401 |
| UNSPSC | 39121521 |
| IDEA Granular Category Code (IGCC) | 4731 >> Manual Starters |
| E-Number (Finland) | 3707287 |
| E-Number (Norway) | 4364123 |
| E-Number (Sweden) | 3110054 |
| Feature Name | Feature Value |
|---|---|
| Overload release current setting (EF002336) | 23 A |
| Adjustment range undelayed short-circuit release (EF007131) | 480 A |
| With thermal overload protection (EF006233) | Yes |
| Phase failure sensitive (EF007400) | Yes |
| Switch off technique (EF007007) | Thermomagnetic |
| Rated operating voltage (EF001435) | 250 V |
| Rated permanent current Iu (EF001389) | 32 A |
| Rated operation power at AC-3, 230 V (EF007025) | 15 kW |
| Rated operation power at AC-3, 400 V (EF001364) | 15 kW |
| Type of electrical connection of main circuit (EF006819) | Screw connection |
| Type of control element (EF006976) | Rotating button |
| Device construction (EF008240) | Complete device in housing |
| With integrated auxiliary switch (EF001387) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Rated short-circuit breaking capacity Icu at 400 V, AC (EF007049) | 100 kA |
| Degree of protection (IP) (EF005474) | IP20 |
| Height (EF000040) | 142.65 mm |
| Width (EF000008) | 55 mm |
| Depth (EF000049) | 122.1 mm |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE MOTOR PROTECTION EN.pdf | 70 Mbytes |
|
| MS165-32 Manual Motor Starter - ABB - MS165-32 - 1SAM451000R1014 | 97 Kbytes |
![]() |
| MS165-32 1SAM451000R1014 ABB MS165-32 Manual Motor Starter | 77 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.