ANUNCIAR
1SAM350000R1007 ABB MS132-2.5 Manual Motor Starter View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SAM350000R1007 ABB MS132-2.5 Manual Motor Starter

1SAM350000R1007

ABB

MS132-2.5 Manual Motor Starter

MS132-2.5 MOTOR GUARD REG.1.6-2.5A

MS132-2.5 Manual Motor Starter 1.6 ... 2.5 A

More details


Low-voltage industrial components > Motor protection circuit-breaker

Electronic motor protection relays > Electronic motor protection relays Mx116 and Mx132

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $77.79
Unit price: $77.79
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Often bought together

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85362010
Popular Downloads
Data Sheet, Technical Information2CDC131021D0202
Instructions and Manuals2CDC131022M6802
Instructions and Manuals (Part 2)2CDC131060M0202
Ex Operating Instructions2CDC131063M6801
Time-Current Characteristic Curve1SAM300505F0107
I²t Characteristic1SAM300507F0001
1SAM300507F0003
Cut-off Current Characteristic1SAM300508F0001
1SAM300508F0003
CAD Dimensional Drawing2CDC001079B0201
Dimension Diagram1SAM300402F0001
Dimensions
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length86.75 mm
Product Net Weight0.265 kg
Technical
Rated Service Short-Circuit Breaking Capacity (Ics)(230 V AC) 100 kA
(250 V DC) 3 Poles in Series 10 kA
(400 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(690 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(690 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)31.3 A
Setting Range1.6 ... 2.5 A
Rated Operational Power AC-3 (Pe)(400 V) Three Phase 0.75 kW
Rated Operational Power AC-3e (Pe)(400 V) Three Phase 0.75 kW
Rated Operational VoltageMain Circuit 690 V AC
Main Circuit 250 V DC
Rated Operational Current (Ie)2.5 A
Rated Operational Current AC-3 (Ie)2.5 A
Rated Operational Current AC-3e (Ie)2.5 A
Rated Operational Current DC-5 (Ie)2.5 A
Rated Frequency (f)Main Circuit 50 Hz
Main Circuit 60 Hz
Operating Frequency (fsw)0 ... 400 Hz
Rated Impulse Withstand Voltage (Uimp)Main Circuit 6 kV
Rated Insulation Voltage (Ui)690 V
Power Lossat Rated Operating Conditions per Pole 0.7 ... 1.8 W
Number of Poles3P
Conventional Free-air Thermal Current (Ith)Main Circuit 2.5 A
Degree of ProtectionHousing IP20
Main Circuit Terminals IP10
Pollution Degree3
Electrical Durability50000 cycle
Mechanical DurabilityNr. Operations 100000 cycle
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Tightening TorqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Recommended Screw DriverPozidriv 2
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Actuator TypeRotary Handle
Contact Position IndicationON / OFF / TRIP
StandardsIEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
RemarksUL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx
Technical UL/CSA
Short-Circuit Current Rating (SCCR)Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Horsepower Rating UL/CSA(200 V AC) Three Phase 0.5 Hp
(208 V AC) Three Phase 0.5 Hp
(220 ... 240 V AC) Three Phase 0.5 Hp
(440 ... 480 V AC) Three Phase 1 Hp
(550 ... 600 V AC) Three Phase 1.5 Hp
Full Load Amps Motor Use(200 V AC) Three Phase 2.5 A
(208 V AC) Three Phase 2.5 A
(220 ... 240 V AC) Three Phase 2.5 A
(440 ... 480 V AC) Three Phase 2.5 A
(550 ... 600 V AC) Three Phase 2.5 A
Locked Rotor Amps(200 V AC) Three Phase 15 A
(208 V AC) Three Phase 15 A
(220 ... 240 V AC) Three Phase 15 A
(440 ... 480 V AC) Three Phase 15 A
(550 ... 600 V AC) Three Phase 15 A
General Use Rating UL/CSA(600 V AC) 2.5 A
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Tightening Torque UL/CSAMain Circuit 10 ... 12 in·lb
Environmental
Ambient Air TemperatureAround the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Ambient Air Temperature CompensationYes
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 25g
Resistance to Vibrations5g 3 ... 150 Hz
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SAA963005-4502
RoHS Declaration1SAA963006-4501
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006539
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
End Of Life Disassembling Instructions1SAC200332H0001
Environmental Product Declaration - EPD1SAC200360H0001
1SAC200385H0001
Certificates and Declarations
A2L Certificate – IEC1SAA963000-4601
ABS Certificate1SAA963001-0101
ATEX Certificate1SAA963000-3902
BV Certificate1SAA963001-0202
CB Certificate1SAA963002-2002
1SAA963007-2002
CCC Certificate2024010307654702
2024010307658958
CQC CertificateCQC2010010307387700
CQC2019010307243864
Cut-off Current Characteristic1SAM300508F0001
1SAM300508F0003
Declaration of Conformity - CCC2020980307003526
2020980307003041
Declaration of Conformity - CE1SAD101100-3402
Declaration of Conformity - UKCA1SAD201100-3402
DNV GL Certificate1SAA963001-0304
EAC Certificate1SAA963000-2701
IECEx Certificate1SAA963000-4001
KC Certificate1SAA963002-1502
LR Certificate1SAA963001-0502
RINA Certificate1SAA963002-0802
RMRS Certificate1SAA918000-0704
UL CertificateE137861-20090225
E345003-20090225
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width92 mm
Package Level 1 Depth / Length95 mm
Package Level 1 Height50 mm
Package Level 1 Gross Weight0.28 kg
Package Level 1 EAN4013614400070
Package Level 2 Unitscarton 40 piece
Package Level 2 Width280 mm
Package Level 2 Depth / Length395 mm
Package Level 2 Height210 mm
Package Level 2 Gross Weight11.586 kg
Package Level 2 EAN4013614408977
External Classifications and Standards
Object Classification CodeF
ETIM 9EC000074 - Motor protection circuit-breaker
ETIM 10EC000074 - Motor protection circuit-breaker
eClassV11.0 : 27370401
UNSPSC39121521
IDEA Granular Category Code (IGCC)4731 >> Manual Starters
E-Number (Finland)3705991
E-Number (Norway)4364076
E-Number (Sweden)3112123

ETIM for 1SAM350000R1007 Low-voltage industrial controls and switchgear (EC000074)
Feature Name Feature Value
Overload release current setting (EF002336) 1.6 A
Adjustment range undelayed short-circuit release (EF007131) 31.3 A
With thermal overload protection (EF006233) Yes
Phase failure sensitive (EF007400) Yes
Switch off technique (EF007007) Thermomagnetic
Rated operating voltage (EF001435) 250 V
Rated permanent current Iu (EF001389) 2.5 A
Rated operation power at AC-3, 230 V (EF007025) 0.75 kW
Rated operation power at AC-3, 400 V (EF001364) 0.75 kW
Type of electrical connection of main circuit (EF006819) Screw connection
Type of control element (EF006976) Rotating button
Device construction (EF008240) Complete device in housing
With integrated auxiliary switch (EF001387) No
With integrated under voltage release (EF001390) No
Number of poles (EF001391) 3
Rated short-circuit breaking capacity Icu at 400 V, AC (EF007049) 100 kA
Degree of protection (IP) (EF005474) IP20
Height (EF000040) 90 mm
Width (EF000008) 45 mm
Depth (EF000049) 86.75 mm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.