MO165-54 MAGNETIC SINGLE MOTOR GUARD 54A

More details


Low-voltage industrial components > Motor protection circuit-breaker

Electronic motor protection relays > Electronic motor protection relays Mx116 and Mx132

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $205.43
Unit price: $205.43
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85362010
Popular Downloads
Data Sheet, Technical Information2CDC131084D0201
Instructions and Manuals2CDC131082M6801
Instructions and Manuals (Part 2)2CDC131060M0202
Time-Current Characteristic Curve1SAM400515F0001
I²t Characteristic1SAM400506F0001
Cut-off Current Characteristic1SAM400507F0001
CAD Dimensional Drawing2CDC001079B0201
Dimension Diagram1SAM400402F0001
Dimensions
Product Net Width55 mm
Product Net Height142.65 mm
Product Net Depth / Length122.1 mm
Product Net Weight0.97 kg
Technical
Rated Service Short-Circuit Breaking Capacity (Ics)(230 V AC) 30 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 30 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 6 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V AC) 50 kA
(250 V DC) 100 kA
(400 V AC) 50 kA
(440 V AC) 45 kA
(500 V AC) 20 kA
(690 V AC) 8 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)810 A
Setting RangeNone
Rated Operational Power AC-3 (Pe)(400 V) Three Phase 22 kW
Rated Operational Power AC-3e (Pe)(400 V) Three Phase 22 kW
Rated Operational VoltageMain Circuit 690 V AC
Main Circuit 250 V DC
Rated Operational Current (Ie)54 A
Rated Operational Current AC-3 (Ie)54 A
Rated Operational Current AC-3e (Ie)54 A
Rated Operational Current DC-5 (Ie)54 A
Rated Frequency (f)Main Circuit 50 Hz
Main Circuit 60 Hz
Operating Frequency (fsw)0 ... 415 Hz
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Rated Insulation Voltage (Ui)1000 V
Power Loss7 W
Number of Poles3P
Conventional Free-air Thermal Current (Ith)Main Circuit 54 A
Degree of ProtectionHousing IP20
Main Circuit Terminals IP10
Pollution Degree3
Electrical Durability25000 cycle
Mechanical DurabilityNr. Operations 50000 cycle
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Tightening TorqueMain Circuit 4 N·m
Wire Stripping LengthMain Circuit 16 mm
Recommended Screw DriverPozidriv 2
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Actuator TypeRotary Handle
Contact Position IndicationON / OFF / TRIP
StandardsCSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1
RemarksFor overload protection of the motors, an appropriate thermal or electronic overload relays must be used
Technical UL/CSA
Short-Circuit Current Rating (SCCR)Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Horsepower Rating UL/CSA(200 V AC) Three Phase 15 Hp
(208 V AC) Three Phase 15 Hp
(220 ... 240 V AC) Three Phase 20 Hp
(440 ... 480 V AC) Three Phase 40 Hp
(550 ... 600 V AC) Three Phase 50 Hp
Full Load Amps Motor Use(200 V AC) Three Phase 48.3 A
(208 V AC) Three Phase 46.2 A
(220 ... 240 V AC) Three Phase 54 A
(440 ... 480 V AC) Three Phase 52 A
(550 ... 600 V AC) Three Phase 52 A
Locked Rotor Amps(200 V AC) Three Phase 267 A
(208 V AC) Three Phase 257 A
(220 ... 240 V AC) Three Phase 290 A
(440 ... 480 V AC) Three Phase 290 A
(550 ... 600 V AC) Three Phase 290 A
General Use Rating UL/CSA(600 V AC) 54 A
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 16-0 AWG
Stranded 1/2x 16-0 AWG
Tightening Torque UL/CSAMain Circuit 35 in·lb
Environmental
Ambient Air TemperatureOperation -25 ... +60 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Ambient Air Temperature CompensationNo
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 25g
Resistance to VibrationsMounted on Mounting Plate: 5g 3 ... 150 Hz
Mounted on DIN-Rail: 4g 3 ... 150 Hz
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SAA963005-4502
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006539
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
End Of Life Disassembling Instructions1SAC200284H0001
Environmental Product Declaration - EPD1SAC200253H0001
Certificates and Declarations
ABS Certificate1SAA963002-0101
BV Certificate1SAA963002-0201
CB Certificate1SAA918002-2002
CCC Certificate2024010307654703
CQC CertificateCQC2015010307760141
Cut-off Current Characteristic1SAM400507F0001
Declaration of Conformity - CCC2020980307003042
Declaration of Conformity - CE1SAD101100-3409
Declaration of Conformity - UKCA1SAD201100-3409
DNV GL Certificate1SAA963002-0301
EAC Certificate1SAA963000-2701
IECEx Certificate1SAA918000-4001
KC Certificate1SAA963001-1501
LR Certificate1SAA918001-0501
RMRS Certificate1SAA918000-0704
UL CertificateE137861-20150206
E345003-20150206
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width64 mm
Package Level 1 Depth / Length177 mm
Package Level 1 Height140 mm
Package Level 1 Gross Weight1.1 kg
Package Level 1 EAN4013614486173
Package Level 2 Unitscarton 12 piece
Package Level 2 Width330 mm
Package Level 2 Depth / Length400 mm
Package Level 2 Height320 mm
Package Level 2 Gross Weight13 kg
Package Level 2 EAN4013614504037
External Classifications and Standards
Object Classification CodeF
ETIM 9EC000074 - Motor protection circuit-breaker
ETIM 10EC000074 - Motor protection circuit-breaker
eClassV11.0 : 27370401
UNSPSC39121521
IDEA Granular Category Code (IGCC)4731 >> Manual Starters
E-Number (Finland)3707296
E-Number (Norway)4364145
E-Number (Sweden)3110143

ETIM for 1SAM461000R1016 Low-voltage industrial controls and switchgear (EC000074)
Feature Name Feature Value
Overload release current setting (EF002336) 54 A
Adjustment range undelayed short-circuit release (EF007131) 810 A
With thermal overload protection (EF006233) No
Phase failure sensitive (EF007400) No
Switch off technique (EF007007) Magnetic
Rated operating voltage (EF001435) 250 V
Rated permanent current Iu (EF001389) 54 A
Rated operation power at AC-3, 230 V (EF007025) 22 kW
Rated operation power at AC-3, 400 V (EF001364) 22 kW
Type of electrical connection of main circuit (EF006819) Screw connection
Type of control element (EF006976) Rotating button
Device construction (EF008240) Complete device in housing
With integrated auxiliary switch (EF001387) No
With integrated under voltage release (EF001390) No
Number of poles (EF001391) 3
Rated short-circuit breaking capacity Icu at 400 V, AC (EF007049) 50 kA
Degree of protection (IP) (EF005474) IP20
Height (EF000040) 142.65 mm
Width (EF000008) 55 mm
Depth (EF000049) 122.1 mm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.