MO165-32 Manual motor starter Magnetic only 32 A

Ordering

  • EAN:
    4013614486159
  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85362010

Dimensions

  • Product Net Width:
    55mm
  • Product Net Height:
    142.65mm
  • Product Net Depth:
    122.1mm
  • Product Net Weight:
    0.97kg

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    78 mm
  • Package Level 1 Height:
    155 mm
  • Package Level 1 Length:
    155 mm
  • Package Level 1 Gross Weight:
    1.1 kg
  • Package Level 2 Units:
    12 piece
  • Package Level 2 Width:
    330 mm
  • Package Level 2 Height:
    320 mm
  • Package Level 2 Length:
    400 mm
  • Package Level 2 Gross Weight:
    13 kg
  • Package Level 2 EAN:
    4013614504013

Environmental

  • Ambient Air Temperature:
    Operation -25 ... +60 °C
    Operation Compensated -25 ... +60 °C
    Storage -50 ... +80 °C
  • Ambient Air Temperature Compensation:
    No
  • Maximum Operating Altitude Permissible:
    2000 m
  • Resistance to Shock acc. to IEC 60068-2-27:
    11 ms Pulse 25g
  • Resistance to Vibrations acc. to IEC 60068-2-6:
    5g / 3 ... 150 Hz
  • RoHS Status:
    Following EU Directive 2011/65/EC

Technical UL/CSA

  • Maximum Operating Voltage UL/CSA:
    Main Circuit 600 V AC
  • Ampere Rating UL/CSA:
    32 A
  • Horsepower Rating UL/CSA:
    (208 V AC) Three Phase 10 Hp
    (220 ... 240 V AC) Three Phase 10 Hp
    (440 ... 480 V AC) Three Phase 20 Hp
    (550 ... 600 V AC) Three Phase 30 Hp
  • General Use Rating UL/CSA:
    (600 V AC) 32 A
  • Connecting Capacity Main Circuit UL/CSA:
    Flexible 1/2x 16 ... 0 AWG
    Stranded 1/2x 16 ... 0 AWG
  • Tightening Torque UL/CSA:
    35 in·lb
    Main Circuit 35 in·lb

Additional Information

  • Actuator Type:
    Rotary Handle
  • Connecting Capacity-Main Circuit:
    Flexible with Ferrule 1/2x 1 ... 35 mm²
    Flexible with Insulated Ferrule 1/2x 1 … 35 mm²
    Flexible 1/2x 1 ... 35 mm²
    Solid 1/2x 1 … 50 mm²
  • Conventional Free-air Thermal Current (Ith):
    Main Circuit 32 A
  • Degree of Protection:
    Housing IP20
    Main Circuit Terminals IP10
  • Electrical Durability:
    25000 cycle
  • Mechanical Durability:
    50000 cycle
  • Mounting on DIN Rail:
    TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
    TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
  • Mounting Position:
    Position 1 to 6
  • Number of Poles:
    3
  • Pollution Degree:
    3
  • Power Loss:
    4.4 W
  • Product Main Type:
    MO165
  • Product Name:
    Manual Motor Starter Magnetic Only
  • Rated Current (In):
    32 A
  • Rated Frequency (f):
    Main Circuit 50 Hz
    Main Circuit 60 Hz
  • Rated Impulse Withstand Voltage (Uimp):
    Main Circuit 8 kV
  • Rated Instantaneous Short-Circuit Current Setting (Ii):
    480 A
  • Rated Insulation Voltage (Ui):
    1000 V
  • Rated Operational Current (Ie):
    32 A
  • Rated Operational Current AC-3 (Ie):
    32 A
  • Rated Operational Current DC-5 (Ie):
    32 A
  • Rated Operational Power AC-3 (Pe):
    (400 V) Three Phase 15 kW
  • Rated Operational Voltage:
    Main Circuit 1000 V AC
  • Rated Service Short-Circuit Breaking Capacity (Ics):
    (230 V AC) 50 kA
    (250 V DC) 3 Poles in Series 100 kA
    (400 V AC) 100 kA
    (440 V AC) 50 kA
    (500 V AC) 20 kA
    (690 V AC) 5 kA
  • Rated Ultimate Short-Circuit Breaking Capacity (Icu):
    (230 V AC) 100 kA
    (250 V DC) 100 kA
    (400 V AC) 100 kA
    (440 V AC) 50 kA
    (500 V AC) 20 kA
    (690 V AC) 5 kA
  • Recommended Screw Driver:
    Pozidriv 2
  • Remarks:
    For overload protection of the motors, an appropriate thermal or electronic overload relays must be used
  • Setting Range:
    None
  • Standards:
    IEC/EN 60947-1
    IEC/EN 60947-2
    IEC/EN 60947-4-1
    UL 60947-4-1
    CSA 22.2 No. 14
  • Terminal Type:
    Screw Terminals
  • Tightening Torque:
    Control Circuit 4 N·m
    Main Circuit 4 N·m
  • Wire Stripping Length:
    Main Circuit 16 mm

Certificates and Declarations (Document Number)

Classifications

  • eClass:
    7.0 27370401
  • ETIM 5:
    EC000074 - Motor protective circuit-breaker
  • Object Classification Code:
    F
  • UNSPSC:
    39121521

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.