ANUNCIAR
2CCS561001R1978 ABB Miniature Circuit Breakers MCBs View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

2CCS561001R1978 ABB Miniature Circuit Breakers MCBs

2CCS561001R1978

ABB

Miniature Circuit Breakers MCBs

SMISSLINE-S401M-UCZ1.6 I.Aut. 6KA

Miniature Circuit Breaker - S400 - 1P - 1.6 A - UC-Z - (230 V) 10 kA

More details


Circuit breakers and fuses > Miniature circuit breaker (MCB)

Industrial > SMISSLINE

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $132.31
Unit price: $132.31
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



ABB EcoSolutions
ABB EcoSolutionsYes
EcoSolutions Profile9AKK108469A7869
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 92.67 %
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
Sustainable Material Content in Packaging (wt. %)Recycled Cardboard - 18.12 %
Recycled Cardboard - 67.66 %
Chemically Recycled Polymer - 0 %
Extended Product LifetimeProduct Durability
End Of Life Disassembling Instructions9AKK108469A6908
Environmental Product Declaration - EPD9AKK108469A5737
Technical
Rated Operational Current (Ie)1.6 A
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V) 25 kA
(400 V) 25 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V DC) 10 kA
(110 V DC) 10 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)50 %
Power Supply ConnectionArbitrary
Contact Position IndicationRed ON / Green OFF
Energy Limiting Class3
Electrical Endurance10000 cycle
Mechanical Endurance10000 cycle
Number of Protected Poles1
Number of Poles1P
Tightening Torque2.8 N·m
Trip ClassUC-Z
Release TypeZ
Screw Terminal TypeFailsafe Bi-directional Cylinder-lift Terminal
Actuator MarkingI / O
Recommended Screw DriverPozidriv 2
Accessories AvailableYes
Connecting CapacityFlexible 0.75 … 25 mm²
Rigid 0.75 … 35 mm²
Terminal TypeScrew Terminals
Electrical
Tripping CharacteristicUC-Z
Rated Operational Voltageacc. to IEC 60898-1 230 V
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 440 V
Rated Impulse Withstand Voltage (Uimp)4 kV
Input Voltage TypeAC/DC
Rated Current (In)1.6 A
Rated Short-Circuit Capacity(230 V) 10 kA
(400 V) 10 kA
Frequency (f)50 ... 60 Hz
Rated Frequency (f)50 ... 60 Hz
Power LossTotal 2.7 W
Overvoltage CategoryIII
Material Compliance
RoHS Declaration9AKK107991A9644
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Date20210407
REACH Declaration9AKK108467A9561
REACH InformationTrue - contains substances > 0.1 mass percentage
REACH Date20230417
Conflict Minerals Reporting Template (CMRT)9AKK108468A3363
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2BBusiness To Business
Environmental
Ambient Air TemperatureOperation -25 … 60 °C
Reference Ambient Air Temperature30 °C
Degree of ProtectionIP20
Pollution Degree2
Resistance to Vibrations1 mm 2 … 13.2 Hz
Environmental Information9AKK108467A9561
Dimensions
Width in Number of Modular Spacings1
Product Net Width100 mm
Product Net Height91 mm
Product Net Depth / Length75 mm
Product Net Weight145 g
Built-In Depth (t2)91 mm
Dimension Diagram9AKK107492A6192
Engineering
EPLAN Data9AAC128473_EPLAN
Ordering
Package Level 1 Unitscarton 10 piece
Package Level 1 Gross Weight1514 g
E-Number (Norway)1623280
E-Number (Switzerland)809611107
Certificates and Declarations
Declaration of Conformity - CE9AKK107991A9644
Installation
Instructions and Manuals2CCC451019M0109
Mounting PositionAny
Popular Downloads
Data Sheet, Technical Information9AKK107492A6192
External Classifications and Standards
ETIM 9EC000042 - Miniature circuit breaker (MCB)
ETIM 10EC000042 - Miniature circuit breaker (MCB)
UNSPSC39121603
eClassV11.0 : 27141901
Object Classification CodeFC
StandardsIEC/EN 60947-2

ETIM for 2CCS561001R1978 Circuit breakers and fuses (EC000042)
Feature Name Feature Value
Built-in depth (EF000218) 91 mm
Release characteristic (EF000889) Other
Number of poles (total) (EF008618) 1
Number of protected poles (EF005548) 1
Rated current (EF000227) 1.6 A
Rated voltage (EF000228) 230 V
Rated insulation voltage Ui (EF001366) 440 V
Rated impulse withstand voltage Uimp (EF011980) 4 kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V (EF009556) 10 kA
Voltage type (EF000187) AC/DC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V (EF009555) 10 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V (EF009557) 25 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V (EF009558) 25 kA
Frequency (EF000416) 50 Hz
Current limiting class (EF002568) 3
Flush-mounted installation (EF007517) No
Concurrently switching neutral conductor (EF005997) No
Over voltage category (EF002569) 3
Pollution degree (EF002570) 2
Additional equipment possible (EF008148) Yes
Width in number of modular spacings (EF002950) 1
Degree of protection (IP) (EF005474) IP20
Ambient temperature during operating (EF007515) -25 °C
Connectable conductor cross section multi-wired (EF007343) 0.75 mm²
Connectable conductor cross section solid-core (EF007337) 0.75 mm²
Explosion-proof (EF004663) No

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.