ANUNCIAR
GJH1213001R0401 ABB KC6-40E-01 Mini Contactor Relay 24VDC View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

GJH1213001R0401 ABB KC6-40E-01 Mini Contactor Relay 24VDC

GJH1213001R0401

ABB

KC6-40E-01 Mini Contactor Relay 24VDC

KC6-40E MINICONT. AUX. 24VDC. TOR.

KC6-40E-01Mini Contactor Relay24 V DC4NO0NCScrew Terminals

More details


Low-voltage industrial components > Contactor relay

Contactors and overload relays > Minicontactors B6-B7

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $45.20
Unit price: $45.20
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85365080
Popular Downloads
EPLAN Data9AAC202735_EPLAN
Data Sheet, Technical Information1SBC100214C0202
Instructions and Manuals2CDC102047M6801
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width52.5 mm
Product Net Depth / Length46.5 mm
Product Net Height57.5 mm
Product Net Weight0.175 kg
Dimension DiagramGJL1200436F0001
Technical
Number of Main Contacts NO0
Number of Main Contacts NC0
Number of Auxiliary Contacts NO4
Number of Auxiliary Contacts NC0
Number of Poles4P
StandardsIEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Rated Operational VoltageAuxiliary Circuit 690 V AC
Auxiliary Circuit 250 V DC
Rated Frequency (f)Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Control Circuit DC
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit DC
Conventional Free-air Thermal Current (Ith)Auxiliary Circuit 6 A
Rated Operational Current AC-15 (Ie)(24 V) 4 A
(120 V) 4 A
(240 V) 4 A
(400 V) 3 A
(500 V) 2 A
Rated Operational Current DC-13 (Ie)(24 V) 2.5 A
(110 V) 0.7 A
(220 / 240 V) 0.4 A
Short-Circuit Protective DevicesgG Type Fuses 6 A
Rated Insulation Voltage (Ui)690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency(AC-15) 600 cycles per hour
(DC-13) 600 cycles per hour
Mechanical DurabilityNr. Operations 10000000 cycle
Minimum Switching Capacity17 V
5 mA
Coil Operating Limits(acc. to IEC 60947-5-1) for DC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc)24 V DC
Coil ConsumptionAverage Holding Value DC 3.5 W
Average Pull-in Value DC 3.5 W
Power Lossat Rated Operating Conditions per Pole 0.32 W
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Wire Stripping LengthAuxiliary Circuit 9 mm
Degree of ProtectionAuxiliary Circuit Terminals IP20
Control Circuit Terminals IP20
Recommended Screw DriverM3
Pozidriv 1
Tightening TorqueAuxiliary Circuit 0.8 ... 1.1 N·m
Control Circuit 0.8 ... 1.1 N·m
Main Circuit 0.8 ... 1.1 N·m
Terminal TypeScrew Terminals
Mini Contactor TypeMini Contactor Relay
Product NameMini Contactor Relay
Technical UL/CSA
Maximum Operating Voltage UL/CSA600 V AC
General Use Rating UL/CSA(600 V AC) 5 A
Connecting Capacity Auxiliary Circuit UL/CSAStranded 1/2x 22-10 AWG
Contact Rating UL/CSAA600
Tightening Torque UL/CSAAuxiliary Circuit 7 in·lb
Control Circuit 7 in·lb
Environmental
Ambient Air TemperatureOperation -25 ... +55 °C
Storage -40 ... +80 °C
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 15g
Resistance to Vibrations3g 3 ... 150 Hz
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
End Of Life Disassembling Instructions1SBC100156C0269
Environmental Product Declaration - EPD1SAC200409H0001
Certificates and Declarations
A2L Certificate – IEC1SAA938000-4601
CB Certificate1SAA938001-2001
CQC CertificateCQC2003010304064035
Declaration of Conformity - CCC2020980304001309
Declaration of Conformity - CE1SAD101100-3101
Declaration of Conformity - UKCA1SAD201100-3101
EAC Certificate1SAA938001-2701
RMRS Certificate1SAA938001-0704
UL CertificateE48139-19881214
Container Information
Package Level 1 Unitsbox 10 piece
Package Level 1 Width115 mm
Package Level 1 Depth / Length280 mm
Package Level 1 Height54 mm
Package Level 1 Gross Weight1.82 kg
Package Level 1 EAN4013614410970
External Classifications and Standards
Object Classification CodeK
ETIM 7EC000196 - Contactor relay
ETIM 8EC000196 - Contactor relay
ETIM 9EC000196 - Contactor relay
eClassV11.0 : 27371001
UNSPSC39121529
IDEA Granular Category Code (IGCC)4763 >> Power contactor, DC switching
E-Number (Finland)3709129

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.