ANUNCIAR
2CDS212001R0064 ABB Int.aut. SH202-C6 2p 6A C 6kA View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

2CDS212001R0064 ABB Int.aut. SH202-C6 2p 6A C 6kA

2CDS212001R0064

ABB

Int.aut. SH202-C6 2p 6A C 6kA

Miniature Circuit Breaker - SH200 - 2P - 6 A - C - (AC) 6 kA

More details


Circuit breakers and fuses > Miniature circuit breaker (MCB)

Residential / Tertiary > SH200

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $26.10
Unit price: $26.10
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

Best sellers

More info



ABB EcoSolutions
ABB EcoSolutionsYes
EcoSolutions Profile9AKK108471A1003
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 92.1 %
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
Extended Product LifetimeProduct Durability
End Of Life Disassembling Instructions9AKK108468A3121
Environmental Product Declaration - EPD9AKK108468A1580
Technical
Dielectric Test Voltage50 / 60 Hz - 1 min 2 kV
Power Supply ConnectionArbitrary
Contact Position IndicationON / OFF
Energy Limiting Class3
Electrical Endurance20000 AC cycle
Mechanical Endurance20000 cycle
Number of Protected Poles2
Number of Poles2P
Tightening Torque2 N·m
Actuator TypeToggle
Screw Terminal TypeCage Terminal
Actuator MarkingI / O
Actuator MaterialInsulation Group II, Black, Sealable
Recommended Screw DriverPozidriv 2
Accessories AvailableNo
Connecting CapacityConductor 25 / 25 mm²
Flexible with Ferrule 0.75 ... 16 mm²
Flexible 0.75 ... 16 mm²
Rigid 0.75 ... 25 mm²
Stranded 0.75 ... 25 mm²
Installation Sizeacc. to DIN 43880 1
Terminal TypeScrew Terminals
Electrical
Tripping CharacteristicC
Rated Operational Voltageacc. to IEC 60898-1 400 V
Operational VoltageMaximum (Incl. Tolerance) 440 V AC
Minimum 12 V AC
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 440 V
Rated Impulse Withstand Voltage (Uimp)4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
Input Voltage TypeAC
Rated Current (In)6 A
Rated Short-Circuit Capacity(AC) 6 kA
(400 V AC) 6 kA
Rated Conditional Short-Circuit Current (Inc)(230 V) 6 kA
(400 V) 6 kA
Rated Frequency (f)50 / 60 Hz
Power Loss4 W
at Rated Operating Conditions per Pole 2 W
Overvoltage CategoryIII
Design
Housing MaterialInsulation Group II, RAL 7035
Material Compliance
RoHS Declaration2CDK400607D2703
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Date20210608
REACH Declaration9AKK107492A1906
REACH InformationFalse - does not contain substances > 0.1 mass percentage
REACH Date20251028
Conflict Minerals Reporting Template (CMRT)9AKK108468A3363
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2BBusiness To Business
Environmental
Ambient Air TemperatureOperation -25 ... +55 °C
Storage -40 ... +70 °C
Reference Ambient Air Temperature30 °C
Degree of ProtectionIP20
Enclosure with Cover IP40
Pollution Degree2
Environmental Conditions28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
Resistance to Vibrations20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
Resistance to Shock acc. to IEC 60068-2-2725g 2 shocks 13 ms
Environmental Information2CDK400030D0201
Dimensions
Width in Number of Modular Spacings2.0
Product Net Width35 mm
Product Net Height88 mm
Product Net Depth / Length69 mm
Product Net Weight0.204 kg
Pole Net Weight0.125 kg
Built-In Depth (t2)69 mm
Ordering
Package Level 1 Unitscarton 5 piece
Package Level 1 Gross Weight1.06 kg
Certificates and Declarations
Declaration of Conformity - CE2CDK400607D2703
Installation
Instructions and Manuals2CDS207105P0001
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting Positionany
Popular Downloads
Data Sheet, Technical Information2CSC400030D0202
External Classifications and Standards
ETIM 9EC000042 - Miniature circuit breaker (MCB)
ETIM 10EC000042 - Miniature circuit breaker (MCB)
UNSPSC39121603
eClassV11.0 : 27141901
IDEA Granular Category Code (IGCC)4897 >> Miniature circuit breakers
Object Classification CodeF
StandardsIEC/EN 60898-1
Certification AgencyEN
IEC

ETIM for 2CDS212001R0064 Circuit breakers and fuses (EC000042)
Feature Name Feature Value
Built-in depth (EF000218) 69 mm
Release characteristic (EF000889) C
Number of poles (total) (EF008618) 2
Number of protected poles (EF005548) 2
Rated current (EF000227) 6 A
Rated voltage (EF000228) 400 V
Rated insulation voltage Ui (EF001366) 440 V
Rated impulse withstand voltage Uimp (EF011980) 4 kV
Voltage type (EF000187) AC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V (EF009555) 6 kA
Frequency (EF000416) 50 Hz
Current limiting class (EF002568) 3
Flush-mounted installation (EF007517) No
Concurrently switching neutral conductor (EF005997) No
Over voltage category (EF002569) 3
Pollution degree (EF002570) 2
Additional equipment possible (EF008148) No
Width in number of modular spacings (EF002950) 2.0
Degree of protection (IP) (EF005474) IP20
Ambient temperature during operating (EF007515) -25 °C
Connectable conductor cross section multi-wired (EF007343) 0.75 mm²
Connectable conductor cross section solid-core (EF007337) 0.75 mm²
Explosion-proof (EF004663) No

Datasheet - PDF

Title: Size: Type:
PDF MINIATURE CIRCUIT BREAKERS EN .pdf 37 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.