S802S-UCK100
2CCS862001R1637
ABB
1
High Performance Circuit Breaker - S800S - Tripping characteristic K - Number of poles 2 - Rated operational current 100A - Rated operational voltage 250V DC
Int.aut. S802S-UCK100 2p 100A UCK 50kA
S802S-UCK100 High Performance MCB
Circuit breakers and fuses > Miniature circuit breaker (MCB)
Industrial > S800S-UC
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| EcoSolutions Profile | 9AKK108471A1082 |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 86.29 % |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| End Of Life Disassembling Instructions | 9AKK108470A2575 |
| Environmental Product Declaration - EPD | 9AKK108470A1695 |
| 9AKK108470A1696 | |
| Technical | |
| Type of Residual Current | Standard Version |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (500 V DC) 50 kA |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (500 V DC) 50 kA |
| Contact Position Indication | ON / OFF / TRIP |
| Energy Limiting Class | 3 |
| Number of Protected Poles | 2 |
| Number of Poles | 2P |
| Release Type | K |
| Actuator Marking | I / O |
| Accessories Available | Yes |
| Connecting Capacity | Flexible 0 … 50 mm² |
| Rigid 0 … 70 mm² | |
| Terminal Type | Screw Terminals |
| Electrical | |
| Tripping Characteristic | UC-K |
| Rated Operational Voltage | acc. to IEC 60947-2 500 V DC |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 1500 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Input Voltage Type | DC |
| Rated Current (In) | 100 A |
| Rated Conditional Short-Circuit Current (Inc) | (230 V) 50 kA |
| (400 V) 50 kA | |
| Frequency (f) | 50...60 Hz |
| Rated Frequency (f) | 0 Hz |
| Power Loss | 16.6 W |
| at Rated Operating Conditions per Pole 8.3 W | |
| Overvoltage Category | III |
| Material Compliance | |
| RoHS Declaration | 2CCC005084D0202 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| RoHS Date | 20211214 |
| REACH Declaration | 9AKK108470A9089 |
| REACH Information | False - does not contain substances > 0.1 mass percentage |
| REACH Date | 20250313 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108468A3363 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B | Business To Business |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +60 °C |
| Storage -40 ... +70 °C | |
| Degree of Protection | IP20 |
| Pollution Degree | 2 |
| Environmental Information | 2CCY413207D0203 |
| Dimensions | |
| Width in Number of Modular Spacings | 3 |
| Product Net Width | 54 mm |
| Product Net Height | 95 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 490 g |
| Built-In Depth (t2) | 82.5 mm |
| Dimension Diagram | 2CCC413003C0201 |
| Engineering | |
| EPLAN Data | 9AAC172534_EPLAN |
| Ordering | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Gross Weight | 510 g |
| Certificates and Declarations | |
| CB Certificate | 2CCC413025D0202 |
| CCC Certificate | CQC2007010307251328 |
| Declaration of Conformity - CE | 2CCC005084D0202 |
| ESTI Certificate | S800 GOST |
| UL Certificate | 9AKK107680A2286 |
| VDE Certificate | 2CCC413040D0601 |
| Installation | |
| Instructions and Manuals | 2CCC413016M0008 |
| Popular Downloads | |
| Data Sheet, Technical Information | 9AKK108468A9560 |
| 9AKK108468A9561 | |
| 9AKK108468A9562 | |
| External Classifications and Standards | |
| ETIM 9 | EC000042 - Miniature circuit breaker (MCB) |
| ETIM 10 | EC000042 - Miniature circuit breaker (MCB) |
| UNSPSC | 39121603 |
| eClass | V11.0 : 27141901 |
| IDEA Granular Category Code (IGCC) | 4899 >> Miniature circuit breaker (MCB) screw-in model |
| Object Classification Code | F |
| Standards | IEC/EN 60947-2 |
| Feature Name | Feature Value |
|---|---|
| Built-in depth (EF000218) | 82.5 mm |
| Release characteristic (EF000889) | Other |
| Number of poles (total) (EF008618) | 2 |
| Number of protected poles (EF005548) | 2 |
| Rated current (EF000227) | 100 A |
| Rated insulation voltage Ui (EF001366) | 1500 V |
| Rated impulse withstand voltage Uimp (EF011980) | 8 kV |
| Voltage type (EF000187) | DC |
| Frequency (EF000416) | 0 Hz |
| Current limiting class (EF002568) | 3 |
| Flush-mounted installation (EF007517) | No |
| Concurrently switching neutral conductor (EF005997) | No |
| Over voltage category (EF002569) | 3 |
| Pollution degree (EF002570) | 2 |
| Additional equipment possible (EF008148) | Yes |
| Width in number of modular spacings (EF002950) | 3 |
| Degree of protection (IP) (EF005474) | IP20 |
| Ambient temperature during operating (EF007515) | -25 °C |
| Connectable conductor cross section multi-wired (EF007343) | 0 mm² |
| Connectable conductor cross section solid-core (EF007337) | 0 mm² |
| Explosion-proof (EF004663) | No |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.