| Technical | |
|---|---|
| Type of Residual Current | Type A |
| Test Voltage (Ut) | 100-250 V |
| Maximum Surge Current | 0.25 kA |
| Leakage Current Type | A |
| Power Supply Connection | Arbitrary |
| Electrical Endurance | 2000 cycle |
| Mechanical Endurance | 5000 cycle |
| Number of Poles | 4P |
| Number of Modular Spacings per DIN Rail | 4 |
| Operating Characteristic | Instantaneous |
| Position of Neutral Terminals | Right |
| Tightening Torque | 2.8 N·m |
| Accessory Type | Signal/Auxiliary contact |
| Motor operating device | |
| Options Provided | None |
| Accessories Available | Yes |
| Connecting Capacity | Busbar 10 mm² |
| Rigid 35 ... 35 mm² | |
| Flexible 35 ... 35 mm² | |
| Rated Cross-Section | 4 - Multi-Wired 0...25 mm² |
| 1 - Solid-Core 35...35 mm² | |
| Wire Stripping Length | 12 mm |
| Terminal Type | Screw Terminals |
| Electrical | |
| Rated Voltage (Ur) | 230/400 V |
| Rated Operational Voltage | 230 … 400 V AC |
| Rated Insulation Voltage (Ui) | 500 V |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV |
| Input Voltage Type | AC |
| Rated Current (In) | 125 A |
| Rated Residual Current | 300 mA |
| Rated Conditional Short-Circuit Current (Inc) | 10 kA |
| Frequency (f) | 50/60 Hz |
| Rated Frequency (f) | 50 Hz |
| Power Loss | at Rated Operating Conditions per Pole 11.2 W |
| Total 33.6 W | |
| Design | |
| RAL Number | RAL 7035 - Light Grey |
| Number of Modules | 4 |
| Material Compliance | |
| RoHS Declaration | 9AKK106713A5606 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| RoHS Date | 20211115 |
| REACH Declaration | 9AKK108467A9482 |
| REACH Information | True - contains substances > 0.1 mass percentage |
| REACH Date | 20240429 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108468A3363 |
| SCIP | 941b7388-e5f6-48ed-bf9e-6d5653c1c989 Italy |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B | Business To Consumer |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... 40 °C |
| Storage -40 ... 70 °C | |
| Degree of Protection | IP2X |
| Pollution Degree | 2 |
| Environmental Information | Refer to RoHS |
| Dimensions | |
| Width in Number of Modular Spacings | 4 |
| Product Net Width | 72 mm |
| Product Net Height | 85 mm |
| Product Net Depth / Length | 69.5 mm |
| Product Net Weight | 500 g |
| Built-In Depth (t2) | 69 mm |
| Engineering | |
| EPLAN Data | 9AAC202084_EPLAN |
| Ordering | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Gross Weight | 0.545 kg |
| E-Number (Finland) | 3259405 |
| E-Number (Norway) | 1630587 |
| Certificates and Declarations | |
| Declaration of Conformity - CE | 9AKK106713A5606 |
| Installation | |
| Instructions and Manuals | 9AKK107991A6132 |
| 9AKK107991A0963 | |
| Mounting Type | DIN-Rail |
| Mounting Position | Any |
| Popular Downloads | |
| Data Sheet, Technical Information | 9AKK107991A8329 |
| External Classifications and Standards | |
| ETIM 9 | EC000003 - Residual current circuit breaker (RCCB) |
| ETIM 10 | EC000003 - Residual current circuit breaker (RCCB) |
| UNSPSC | 39121601 |
| eClass | V11.0 : 27142201 |
| IDEA Granular Category Code (IGCC) | 4875 >> Residual current circuit breaker (RCCB) |
| Object Classification Code | F |
| Standards | IEC/EN 61008 |
| Feature Name | Feature Value |
|---|---|
| Number of poles (EF001391) | 4 |
| Rated voltage (EF000228) | 400 V |
| Rated current (EF000227) | 125 A |
| Rated insulation voltage Ui (EF001366) | 500 V |
| Rated impulse withstand voltage Uimp (EF011980) | 4 kV |
| Mounting method (EF000003) | DIN rail |
| Leakage current type (EF002560) | A |
| Selective protection (EF002561) | No |
| Short-time delayed tripping (EF003604) | No |
| Surge current capacity (EF002564) | 0.25 kA |
| With interlocking device (EF007385) | Yes |
| Frequency (EF005455) | 50 Hz |
| Additional equipment possible (EF008148) | Yes |
| Degree of protection (IP) (EF005474) | IP2X |
| Width in number of modular spacings (EF002950) | 4 |
| Built-in depth (EF000218) | 69 mm |
| Ambient temperature during operating (EF007515) | -25 °C |
| Pollution degree (EF002570) | 2 |
| Connectable conductor cross section multi-wired (EF007343) | 0 mm² |
| Connectable conductor cross section solid-core (EF007337) | 35 mm² |
| Title: | Size: | Type: |
|---|---|---|
| PDF MINIATURE CIRCUIT BREAKERS EN .pdf | 37 Mbytes |
|
| F204 A-125/0,3 Residual Current Dev. - ABB - F204A-125/0,3 - 2CSF204101R3950 | 86 Kbytes |
![]() |
| F204A-125/0,3 2CSF204101R3950 ABB F204 A-125/0,3 Residual Current Dev. | 73 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.