| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | c83beb1c-b493-4f58-b9a2-32d3294ced3f Italy |
| Simplified SCIP | dd511c3a-3471-4b30-8b42-68c885dc3113 Belgium |
| 95af380b-07d3-4a04-b14d-d8b23a5e6d8d Spain | |
| ff20688b-7efa-45fd-abbf-e8688adb3b28 Germany | |
| cae3a1d2-35c3-439a-a27e-7b710488bfef Sweden | |
| cf4512d0-17c9-4227-b32b-76e83927c99f Germany | |
| 74d80318-04c6-47da-a4b0-164db46ede96 France | |
| 14a193ab-f949-4ae9-95d9-a3adc861c0cf Hungary | |
| c6ae76d3-56f4-4884-ab6f-675d93f819a3 Croatia | |
| 558121f9-a569-4499-9b57-e383f1d48c5f Poland | |
| 65645a10-2554-4b4d-b52d-bc6e4851d2ac Netherlands | |
| 6d404c7e-6dc8-4536-bb08-d6b09f6ea59d Germany | |
| 011880b4-16e1-4717-9cb3-d0a3ca01e0c9 Czech Republic | |
| 8881d000-1678-488b-b951-5eb194f950cc Portugal | |
| 1c2b0033-4858-4268-8894-921d9bfc8fd1 Estonia | |
| 851a1838-e0cc-4963-8fc4-31511a4f4493 Greece | |
| 05f4b370-af4c-4b6e-a8b0-b43d8a191515 Poland | |
| 4d383eaa-4ff7-456a-ba00-3fd4c4cc47c8 Sweden | |
| 1f2ee1c3-c160-4bf0-8711-d3635dd87956 Bulgaria | |
| 7d1d631c-d841-495a-9b22-48e4f71961dc Hungary | |
| 71935fe1-0e4d-4187-b6d6-b03e3d3af6f6 France | |
| 94243ed7-db95-4cc8-97aa-bd0510769aca Norway | |
| 1966afb5-c305-4642-aa2e-5fdbcde576d5 Finland | |
| 65fb7743-116d-40d3-a224-c15e9d06496e Belgium | |
| 5be8430d-47ee-4d19-af1f-221be8802243 Germany | |
| 2394fc1d-5eb6-4821-a52c-ef055bfdc8e9 Poland | |
| 2325ffcf-8aa8-433d-933e-ac871e8078a1 Denmark | |
| fb8fe14a-909f-4da7-89cd-e7307cc22e32 Germany | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644581527 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 684 mm |
| Product Net Height | 461 mm |
| Product Net Depth / Length | 396.5 mm |
| Product Net Weight | 96 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 920 mm |
| Package Level 1 Gross Weight | 116 kg |
| Package Level 1 EAN | 8015644581527 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 5000 cycle |
| Ue = 500 ... 690 V 4000 cycle | |
| 10 cycles per hour | |
| Mechanical Durability | 15000 cycle |
| 60 cycles per hour | |
| Number of Poles | 4P |
| Power Loss | 660 W |
| Rated Current (In) | 4000 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 4000 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 75 kA |
| (230 V AC) 75 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 75 kA | |
| (500 V AC) 75 kA | |
| (660 V AC) 75 kA | |
| (690 V AC) 75 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 75 kA |
| for 3 s 75 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 75 kA |
| (230 V AC) 75 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 75 kA | |
| (500 V AC) 75 kA | |
| (660 V AC) 75 kA | |
| (690 V AC) 75 kA | |
| Rated Uninterrupted Current (Iu) | 4000 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR122/P-LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E4 |
| Terminal Connection Type | Withdrawable Circuit-Breakers |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0016 |
| Instructions and Manuals | 1SDH000460R0002 |
| 1SDH000460R0102 | |
| External Classifications and Standards | |
| Object Classification Code | Q |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E4S 4000 PR122/P-LSI In4000A 4p W MP - ABB - E4S4000 - 1SDA056812R1 | 89 Kbytes |
![]() |
| E4S4000 1SDA056812R1 ABB E4S 4000 PR122/P-LSI In 4000A 4p W MP | 77 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.