| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | a9907643-00c7-490f-b8ec-c135cb9105ca Italy |
| Simplified SCIP | 54303008-e623-49d2-b054-1f3f8f186b5a Belgium |
| 9614ff5e-ef83-4fd2-a165-a88d90a54864 Germany | |
| 379ac0ea-3b3b-4908-90a6-1fb4c0e04ea3 France | |
| 9b3ead56-0dd2-443a-b226-32763109d710 Germany | |
| 754dcc93-1974-40f4-84cc-ae2178c75a5b Sweden | |
| bf478b7b-91b6-495d-8a94-32ac91cddd9f France | |
| 94d6d364-88af-439b-b8cb-0a0ddffb66d5 Hungary | |
| 5905b82f-dc87-4244-b684-542692e60793 Spain | |
| 63a32ca0-3420-4d8e-8435-fe8371064cfb Germany | |
| 694379b6-4ca4-4222-a609-ce6deea03731 Denmark | |
| 64794cfa-aa71-4625-bb2b-c0e958871218 Czech Republic | |
| 9ec96b3f-ef95-451b-9546-6ba76b97ccdb Poland | |
| 9347c381-8793-4e64-a786-40f8f09f66ae Netherlands | |
| 37c7558b-a845-4aeb-b713-865705daf5df Hungary | |
| 3b72d788-043d-4f71-8112-5fa0d31cb08e Croatia | |
| 0f4f7eb9-fb4f-428d-9e93-8107ba51fb9f Estonia | |
| 98a4da0b-dd4f-47e9-9623-ebf43c1445cc Poland | |
| 787200c8-62af-4b34-89a2-fc626552fff6 Sweden | |
| 20bd8f6e-0d42-4739-b278-af4ddd5051e3 Bulgaria | |
| 68e798a1-163e-40ee-96c8-b5f7f2b80d45 Portugal | |
| ebc64b2d-c6cb-494a-b42b-e9e78b8bf589 Greece | |
| 6d375bf2-6428-4871-8bcb-655424d48fce Norway | |
| cf3f9f30-2d97-4c69-ac4c-cabc2d717733 Finland | |
| 97c00f02-f71e-409d-89dc-cf562e1ff4a5 Belgium | |
| abc8fda4-11d3-4eb9-acd8-77eec42f6033 Germany | |
| dfdfe0fd-b738-48ee-9a06-1fadcc6ae1ea Germany | |
| fef4d038-4df1-45a9-80ce-70d798ba91f0 Poland | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644581435 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 594 mm |
| Product Net Height | 461 mm |
| Product Net Depth / Length | 396.5 mm |
| Product Net Weight | 85 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 785 mm |
| Package Level 1 Gross Weight | 100 kg |
| Package Level 1 EAN | 8015644581435 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 5000 cycle |
| Ue = 500 ... 690 V 4000 cycle | |
| 10 cycles per hour | |
| Mechanical Durability | 15000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 660 W |
| Rated Current (In) | 4000 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 4000 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 75 kA |
| (230 V AC) 75 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 75 kA | |
| (500 V AC) 75 kA | |
| (660 V AC) 75 kA | |
| (690 V AC) 75 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 75 kA |
| for 3 s 75 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 75 kA |
| (230 V AC) 75 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 75 kA | |
| (500 V AC) 75 kA | |
| (660 V AC) 75 kA | |
| (690 V AC) 75 kA | |
| Rated Uninterrupted Current (Iu) | 4000 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR122/P-LI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E4 |
| Terminal Connection Type | Withdrawable Circuit-Breakers |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0016 |
| Instructions and Manuals | 1SDH000460R0002 |
| 1SDH000460R0102 | |
| External Classifications and Standards | |
| Object Classification Code | Q |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E4S 4000 PR122/P-LI In4000A 3p W MP - ABB - E4S4000 - 1SDA056803R1 | 89 Kbytes |
![]() |
| E4S4000 1SDA056803R1 ABB E4S 4000 PR122/P-LI In 4000A 3p W MP | 76 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.