| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | b32f897c-7a56-4c4a-92fe-dbfc1a480eb2 Italy |
| Simplified SCIP | 26b04924-c7ac-4e1c-b27f-0f8ec3e6e11c France |
| 4f31ec7a-161b-4b71-b798-c5965956d2b0 Spain | |
| 92a86b37-bc01-41c4-8ba9-1e3035d1a0cb Hungary | |
| 832a9c39-c3d6-490e-8a0b-a198b5b23c66 Germany | |
| 17f8c052-68f2-42fb-b8c1-f8fe30ba03cc Sweden | |
| 7d755bf3-c805-466b-b681-dc4a077a674c Germany | |
| 4258a212-5448-4bf3-a99a-22799f82ba0b Belgium | |
| 2dec6fbb-54ee-4b9e-b695-d168405e1646 Germany | |
| 9a6310b0-10b2-495f-acf0-b93c28f4f941 Poland | |
| bae3a22a-706f-4b43-8616-334665d646e1 Norway | |
| 2bfab3d9-3762-4386-a86b-3ba7cc481c2c Belgium | |
| e7109d6f-83ab-42b2-9c44-57b5b2c5cb3c Germany | |
| ac960d3d-d167-4b7e-b7f0-2d3a0e8417f3 Denmark | |
| 34c4e5e2-eb74-49b2-970c-ef3748a9dc9b Finland | |
| c033b899-f7e6-4fb3-9905-949bea905c5f Estonia | |
| e4c19a47-e937-4cb6-a7ba-d90f89837f0d Portugal | |
| 145c451a-16d7-4474-a41e-222738839612 Greece | |
| d6b405fb-c164-48a0-8dba-3a988ec951f4 Poland | |
| aebda3ad-5e36-47eb-b6b1-7611128a8830 Sweden | |
| 8966d078-47a6-4757-9549-74e0b4d0dca6 Bulgaria | |
| 212cf0d1-f76f-4ffb-a3e3-a37c4cb29c57 Germany | |
| cdb526d1-856c-4177-8aa7-adc0aacd2f48 Croatia | |
| 7b80880f-3435-4341-b7ec-aa20828f4106 Czech Republic | |
| 158661dc-c034-4c34-a40c-675ff55e46c5 Poland | |
| e2c764e3-fa32-4f9b-bf08-defa270de0a4 Hungary | |
| 83e22757-b7b8-4d91-89dd-e4c01ae4b196 Netherlands | |
| 08a662af-7a49-4bac-9894-c80bdd97f6ff France | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644571603 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 414 mm |
| Product Net Height | 461 mm |
| Product Net Depth / Length | 396.5 mm |
| Product Net Weight | 61 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 73 kg |
| Package Level 1 EAN | 8015644571603 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 12000 cycle |
| Ue = 500 ... 690 V 10000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 4P |
| Power Loss | 215 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 1600 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 42 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR122/P-LSI |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E2 |
| Terminal Connection Type | Withdrawable Circuit-Breakers |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0014 |
| Instructions and Manuals | 1SDH000460R0002 |
| 1SDH000460R0102 | |
| External Classifications and Standards | |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Title: | Size: | Type: |
|---|---|---|
| PDF CIRCUIT BREAKERS TMAX XT.pdf | 26 Mbytes |
|
| E2B 1600 PR122/P-LSI In1600A 4p W MP - ABB - E2B1600 - 1SDA055820R1 | 89 Kbytes |
![]() |
| E2B1600 1SDA055820R1 ABB E2B 1600 PR122/P-LSI In 1600A 4p W MP | 79 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.