| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | 99976fbb-e52c-459a-8ffe-5c407bb268ab Italy |
| Simplified SCIP | 748776d3-1849-4601-8563-d257ddd4c4c4 Portugal |
| 5b843a74-6b1e-4ffe-956f-86383321df5f Germany | |
| 6a8d701a-d78d-4952-a5e6-fd9efef54cce Greece | |
| 4ff36f3b-0610-491e-9575-9cb6b43eaf8b Estonia | |
| 15435981-6609-4fdb-be21-36ed68f249b3 Hungary | |
| 38db33b1-74f6-4c7f-9b7b-e553997771dd Belgium | |
| 675e43db-ec21-4c2a-b7be-f2fda85a457b Germany | |
| 067c8df6-f170-4ba3-a937-d0b5a25deee9 Spain | |
| cd859f80-f2a7-49d8-af8f-739e2ffcc0df France | |
| 2653e285-3623-4221-a380-b9be0ef318c3 Sweden | |
| 28d26af0-a14a-43d8-a037-0cc320b93a85 France | |
| 621ec71f-33ee-4c12-9bc9-97f20b127366 Sweden | |
| ecfab959-2968-41f3-a5d7-eec9ea3a526b Germany | |
| 43320e4c-ea44-46e7-8ef4-618a8bbcee62 Poland | |
| cbd8fc25-3963-44cc-9c93-23a1d1859d48 Bulgaria | |
| a603d81e-a94d-4f06-b84b-096e077598ec Germany | |
| 90536ec5-4ac9-415a-84ee-2206f87983fd Denmark | |
| 0ac32ccb-5253-480f-a551-a84e73b688d2 Norway | |
| 935f1b1f-0ed4-4bce-9b7d-0fa0d98b62f5 Poland | |
| 51cf0f44-bd98-4ec8-9bac-b1ef774ad4ff Finland | |
| ebe2e1c4-eab0-47ce-a945-5184f2643e00 Belgium | |
| 24e0c176-495c-42cc-a150-7e7b5be41454 Czech Republic | |
| a94cae32-3b00-424a-b3e9-e439c37583a6 Croatia | |
| 59debe51-0ad4-489b-8bbf-af634d1c1fc1 Germany | |
| 0c907c53-1cec-4e87-a828-db361f310cc8 Poland | |
| 6c0f390e-6666-4bad-bb1e-df3153487afd Netherlands | |
| 53362b10-d884-4c22-ad46-10e536aee786 Hungary | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644570569 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 324 mm |
| Product Net Height | 461 mm |
| Product Net Depth / Length | 396.5 mm |
| Product Net Weight | 44 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 55 kg |
| Package Level 1 EAN | 8015644570569 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 10000 cycle |
| Ue = 500 ... 690 V 10000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 95 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 800 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (660 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA |
| for 3 s 36 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (660 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR122/P-LSI |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E1 |
| Terminal Connection Type | Withdrawable Circuit-Breakers |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0013 |
| Instructions and Manuals | 1SDH000460R0002 |
| 1SDH000460R0102 | |
| External Classifications and Standards | |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Title: | Size: | Type: |
|---|---|---|
| PDF CIRCUIT BREAKERS TMAX XT.pdf | 26 Mbytes |
|
| E1N 800 PR122/P-LSI In800A 3p W MP - ABB - E1N800 - 1SDA055716R1 | 89 Kbytes |
![]() |
| E1N800 1SDA055716R1 ABB E1N 800 PR122/P-LSI In 800A 3p W MP | 77 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.