DDA204 A-63/0,1 - RCD Block
DDA204A-63/0.1 4P 63A At 100mA
Residual Current Device Block DDA200 - 4P - Type A - 100 mA - 63 A
Circuit breakers and fuses > Residual current circuit breaker (RCCB) module
Industrial > DDA200A
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| EcoSolutions Profile | 9AKK108471A0995 |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 69.47 % |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| UL 2799 Zero Waste To Landfill Validation available | |
| Sustainable Material Content in Packaging (wt. %) | Recycled Cardboard - 85.84 % |
| Recycled Paper - 0 % | |
| Recycled Paper - 0 % | |
| Extended Product Lifetime | Product Durability |
| End Of Life Disassembling Instructions | 9AKK108469A7485 |
| Environmental Product Declaration - EPD | 9AKK108469A8934 |
| Technical | |
| Type of Residual Current | Type A |
| Leakage Current Type | A |
| Power Supply Connection | Arbitrary |
| Electrical Endurance | 10000 cycle |
| Number of Poles | 4P |
| Number of Modular Spacings per DIN Rail | 8 |
| Operating Characteristic | Instantaneous |
| Connecting Capacity | Rigid 25 ... 25 mm² |
| Flexible 25 ... 25 mm² | |
| Electrical | |
| Short-Circuit Current Rating (SCCR) | 0.1 ... 0.1 A |
| Rated Voltage (Ur) | 230/400 V |
| Rated Operational Voltage | 230/400 V |
| Rated Insulation Voltage (Ui) | 500 V |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV |
| Rated Current (In) | 63 A |
| Rated Residual Current | 100 mA |
| Rated Frequency (f) | 50 … 60 Hz |
| Power Loss | 7.6 W |
| Design | |
| Number of Modules | 8 |
| Material Compliance | |
| RoHS Declaration | 9AKK106713A5614 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| RoHS Date | 20070731 |
| REACH Declaration | 9AKK108467A9482 |
| REACH Information | True - contains substances > 0.1 mass percentage |
| REACH Date | 20240429 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108468A3363 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B | Business To Consumer |
| Environmental | |
| Ambient Temperature | -25...55 °C |
| Ambient Air Temperature | Operation -25...55 °C |
| Degree of Protection | IP2X |
| Resistance to Vibrations | 20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz |
| Resistance to Shock acc. to IEC 60068-2-27 | 25g 2 shocks 13 ms |
| Environmental Information | Refer to RoHS |
| Dimensions | |
| Product Net Width | 140 mm |
| Product Net Height | 93 mm |
| Product Net Depth / Length | 76 mm |
| Product Net Weight | 311 g |
| Ordering | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Gross Weight | 0.368 kg |
| E-Number (Norway) | 1653185 |
| Certificates and Declarations | |
| Declaration of Conformity - CE | 9AKK106713A5614 |
| Installation | |
| Instructions and Manuals | 9AKK108467A7091 |
| Popular Downloads | |
| Data Sheet, Technical Information | 9AKK107991A8329 |
| External Classifications and Standards | |
| ETIM 9 | EC002297 - Residual current circuit breaker (RCCB) module |
| ETIM 10 | EC002297 - Residual current circuit breaker (RCCB) module |
| eClass | V11.0 : 27142210 |
| Object Classification Code | F |
| Standards | IEC/EN 61009 Ann. G |
| Feature Name | Feature Value |
|---|---|
| Nominal voltage (EF005127) | 230 V |
| Nominal current (EF000001) | 63 A |
| Rated fault current adjustable (EF008874) | No |
| Rated fault current (EF003975) | 0.1 A |
| Delay adjustable (EF001420) | No |
| Number of poles (EF001391) | 4 |
| Leakage current type (EF002560) | A |
| Frequency (EF005455) | 50/60 Hz |
| Rated insulation voltage Ui (EF001366) | 500 V |
| Rated impulse withstand voltage Uimp (EF011980) | 4 kV |
| Connectable conductor cross section solid-core (EF007337) | 25 mm² |
| Connectable conductor cross section multi-wired (EF007343) | 25 mm² |
| Anti-nuisance tripping version (EF009497) | No |
| With interlocking device (EF007385) | Yes |
| Degree of protection (IP) (EF005474) | IP2X |
| Ambient temperature during operating (EF007515) | -25 °C |
| Title: | Size: | Type: |
|---|---|---|
| PDF MINIATURE CIRCUIT BREAKERS EN .pdf | 37 Mbytes |
|
| DDA204 A-63/0,1 - RCD Block - ABB - DDA204A-63/0,1 - 2CSB204101R2630 | 86 Kbytes |
![]() |
| DDA204A-63/0,1 2CSB204101R2630 ABB DDA204 A-63/0,1 RCD Block | 70 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.