ABB GJL1201330R0006 GJL1201330R0006 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

GJL1201330R0006 ABB CAF6-20E Auxiliary Contact

Reference: GJL1201330R0006

Manufacturer: ABB

Description:

CAF6-20E Auxiliary Contact
CAF6-20E Contact AUX. FRON. 2nd
CAF6-20E Auxiliary Contact 2NO/0NC screw terminal, front mounted

Categories:

  • Low-voltage industrial components > Auxiliary contact block
  • ABB > Contactors and overload relays > Minicontactors B6-B7

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

Unit Price: 7,19 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 7-8 days.

  • These delivery times are an estimate any may vary when the item order has been processed.

LAST VIEWED

MORE INFO

Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85365080
Popular Downloads
EPLAN Data9AAC166197_EPLAN
Data Sheet, Technical Information1SBC100214C0202
Instructions and Manuals2CDC102005M0101
Instructions and Manuals (Part 2)2CDC102005M0101
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width47.5 mm
Product Net Depth / Length26.5 mm
Product Net Height29 mm
Product Net Weight0.02 kg
Dimension DiagramGJL1200446F0001
Technical
Number of Main Contacts NO0
Number of Main Contacts NC0
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC0
Number of Poles2P
StandardsIEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Rated Operational VoltageAuxiliary Circuit 690 V AC
Auxiliary Circuit 250 V DC
Rated Frequency (f)Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Conventional Free-air Thermal Current (Ith)Auxiliary Circuit 6 A
Rated Operational Current AC-15 (Ie)(24 V) 4 A
(240 V) 4 A
(500 V) 2 A
(380 / 400 V) 3 A
Rated Operational Current DC-13 (Ie)(24 V) 1.5 A
(110 V) 0.4 A
(220 / 240 V) 0.04 A
Short-Circuit Protective DevicesgG Type Fuses 10 A
Rated Insulation Voltage (Ui)690 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency(AC-15) 600 cycles per hour
(DC-13) 600 cycles per hour
Minimum Switching Capacity17 V
5 mA
Power Lossat Rated Operating Conditions per Pole 0.27 W
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Wire Stripping LengthAuxiliary Circuit 9 mm
Degree of ProtectionIP20
Tightening TorqueAuxiliary Circuit 0.8 ... 1.1 N·m
Terminal TypeScrew Terminals
Suitable ForB6-40-00
BC6-40-00
B7-40-00
BC7-40-00
VB6-40-00
VBC6-40-00
VB7-40-00
VBC7-40-00
VB6A-40-00
VBC6A-40-00
VB7A-40-00
VBC7A-40-00
Suitable for Product ClassMini Contactors
Product NameAuxiliary Contact
Technical UL/CSA
Maximum Operating Voltage UL/CSA600 V AC
General Use Rating UL/CSA(600 V AC) 5 A
Connecting Capacity Auxiliary Circuit UL/CSAStranded 1/2x 22-10 AWG
Contact Rating UL/CSAA600
Tightening Torque UL/CSAAuxiliary Circuit 7 in·lb
Environmental
Ambient Air TemperatureOperation -25 ... +55 °C
Storage -40 ... +80 °C
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 15g
Resistance to Vibrations5g 5 ... 150 Hz
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
A2L Certificate – IEC1SAA938000-4601
CQC CertificateCQC2003010304064035
cULus CertificatecUL_E48139
Declaration of Conformity - CCC2020980304001309
Declaration of Conformity - CE1SAD101100-3101
Declaration of Conformity - UKCA1SAD201100-3101
EAC Certificate1SAA938002-2701
RMRS Certificate1SAA938001-0704
UL CertificateUL_E48139
Container Information
Package Level 1 Unitsbox 10 piece
Package Level 1 Width115 mm
Package Level 1 Depth / Length280 mm
Package Level 1 Height54 mm
Package Level 1 Gross Weight0.24 kg
Package Level 1 EAN4013614412271
External Classifications and Standards
Object Classification CodeK
ETIM 7EC000041 - Auxiliary contact block
ETIM 8EC000041 - Auxiliary contact block
ETIM 9EC000041 - Auxiliary contact block
eClassV11.0 : 27371302
UNSPSC39121522
IDEA Granular Category Code (IGCC)4743 >> Auxiliary contact block
E-Number (Finland)3709097
E-Number (Norway)4184086

ETIM for GJL1201330R0006 Low-voltage industrial controls and switchgear (EC000041)

Feature nameNumber of contacts as change-over contact (EF008257)
Feature value0
Feature nameNumber of contacts as normally open contact (EF008256)
Feature value2
Feature nameNumber of contacts as normally closed contact (EF008255)
Feature value0
Feature nameNumber of fault-signal switches (EF007613)
Feature value0
Feature nameRated operation current Ie at AC-15, 230 V (EF001385)
Feature value4 A
Feature nameType of electric connection (EF003961)
Feature valueScrew connection
Feature nameModel (EF000010)
Feature valueClip-on
Feature nameMounting method (EF000003)
Feature valueFront fastening
Feature nameLamp holder (EF000048)
Feature valueNone

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.