Product successfully added to your shopping cart
AF75-40-00RT
1SBL417210R7200
ABB
1
AF75-40-00RT 20-60V DC Contactor
Contactors and overload relays > Contactors "A" FRCTLP
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SNC001003C0202 |
| Instructions and Manuals | FPTC407767P0002 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 92 mm |
| Product Net Depth / Length | 119.5 mm |
| Product Net Height | 110 mm |
| Product Net Weight | 1.42 kg |
| Technical | |
| Number of Main Contacts NO | 4 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 4P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011 (on request), IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives. |
| Rated Operational Voltage | Main Circuit 690 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 125 A |
| (690 V) 55 °C 105 A | |
| (690 V) 70 °C 85 A | |
| Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 72 A |
| (440 V) 55 °C 70 A | |
| (500 V) 55 °C 65 A | |
| (690 V) 55 °C 46 A | |
| (380 / 400 V) 55 °C 75 A | |
| (220 / 230 / 240 V) 55 °C 75 | |
| Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 40 °C 120 A |
| (110 V) 2 Poles in Series, 55 °C 105 A | |
| (110 V) 2 Poles in Series, 70 °C 85 A | |
| (110 V) 3 Poles in Series, 40 °C 120 A | |
| (110 V) 3 Poles in Series, 55 °C 105 A | |
| (110 V) 3 Poles in Series, 70 °C 85 A | |
| (110 V) 4 Poles in Series, 40 °C 120 A | |
| (110 V) 4 Poles in Series, 55 °C 105 A | |
| (110 V) 4 Poles in Series, 70 °C 85 A | |
| (220 V) 3 Poles in Series, 40 °C 120 A | |
| (220 V) 3 Poles in Series, 55 °C 105 A | |
| (220 V) 3 Poles in Series, 70 °C 85 A | |
| (220 V) 4 Poles in Series, 40 °C 120 A | |
| (220 V) 4 Poles in Series, 55 °C 105 A | |
| (220 V) 4 Poles in Series, 70 °C 85 A | |
| (72 V) 1-Pole, 40 °C 120 A | |
| (72 V) 1-Pole, 55 °C 105 A | |
| (72 V) 1-Pole, 70 °C 85 A | |
| (72 V) 2 Poles in Series, 40 °C 120 A | |
| (72 V) 2 Poles in Series, 55 °C 105 A | |
| (72 V) 2 Poles in Series, 70 °C 85 A | |
| (72 V) 3 Poles in Series, 40 °C 120 A | |
| (72 V) 3 Poles in Series, 55 °C 105 A | |
| (72 V) 3 Poles in Series, 70 °C 85 A | |
| (72 V) 4 Poles in Series, 40 °C 120 A | |
| (72 V) 4 Poles in Series, 55 °C 105 A | |
| (72 V) 4 Poles in Series, 70 °C 85 A | |
| Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 40 °C 120 A |
| (110 V) 2 Poles in Series, 55 °C 105 A | |
| (110 V) 2 Poles in Series, 70 °C 85 A | |
| (110 V) 3 Poles in Series, 40 °C 120 A | |
| (110 V) 3 Poles in Series, 55 °C 105 A | |
| (110 V) 3 Poles in Series, 70 °C 85 A | |
| (110 V) 4 Poles in Series, 40 °C 120 A | |
| (110 V) 4 Poles in Series, 55 °C 105 A | |
| (110 V) 4 Poles in Series, 70 °C 85 A | |
| (220 V) 3 Poles in Series, 40 °C 120 A | |
| (220 V) 3 Poles in Series, 55 °C 105 A | |
| (220 V) 3 Poles in Series, 70 °C 85 A | |
| (220 V) 4 Poles in Series, 40 °C 120 A | |
| (220 V) 4 Poles in Series, 55 °C 105 A | |
| (220 V) 4 Poles in Series, 70 °C 85 A | |
| (72 V) 1-Pole, 40 °C 120 A | |
| (72 V) 1-Pole, 55 °C 105 A | |
| (72 V) 1-Pole, 70 °C 85 A | |
| (72 V) 2 Poles in Series, 40 °C 120 A | |
| (72 V) 2 Poles in Series, 55 °C 105 A | |
| (72 V) 2 Poles in Series, 70 °C 85 A | |
| (72 V) 3 Poles in Series, 40 °C 120 A | |
| (72 V) 3 Poles in Series, 55 °C 105 A | |
| (72 V) 3 Poles in Series, 70 °C 85 A | |
| (72 V) 4 Poles in Series, 40 °C 120 A | |
| (72 V) 4 Poles in Series, 55 °C 105 A | |
| (72 V) 4 Poles in Series, 70 °C 85 A | |
| Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 40 °C 100 A |
| (110 V) 2 Poles in Series, 55 °C 100 A | |
| (110 V) 2 Poles in Series, 70 °C 85 A | |
| (110 V) 3 Poles in Series, 40 °C 120 A | |
| (110 V) 3 Poles in Series, 55 °C 105 A | |
| (110 V) 3 Poles in Series, 70 °C 85 A | |
| (110 V) 4 Poles in Series, 40 °C 120 A | |
| (110 V) 4 Poles in Series, 55 °C 105 A | |
| (110 V) 4 Poles in Series, 70 °C 85 A | |
| (220 V) 3 Poles in Series, 40 °C 75 A | |
| (220 V) 3 Poles in Series, 55 °C 75 A | |
| (220 V) 3 Poles in Series, 70 °C 75 A | |
| (220 V) 4 Poles in Series, 40 °C 100 A | |
| (220 V) 4 Poles in Series, 55 °C 100 A | |
| (220 V) 4 Poles in Series, 70 °C 85 A | |
| (72 V) 1-Pole, 40 °C 75 A | |
| (72 V) 1-Pole, 55 °C 75 A | |
| (72 V) 1-Pole, 70 °C 75 A | |
| (72 V) 2 Poles in Series, 40 °C 120 A | |
| (72 V) 2 Poles in Series, 55 °C 105 A | |
| (72 V) 2 Poles in Series, 70 °C 85 A | |
| (72 V) 3 Poles in Series, 40 °C 120 A | |
| (72 V) 3 Poles in Series, 55 °C 105 A | |
| (72 V) 3 Poles in Series, 70 °C 85 A | |
| (72 V) 4 Poles in Series, 40 °C 120 A | |
| (72 V) 4 Poles in Series, 55 °C 105 A | |
| (72 V) 4 Poles in Series, 70 °C 85 A | |
| Rated Operational Power AC-3 (Pe) | (415 V) 40 kW |
| (440 V) 40 kW | |
| (500 V) 45 kW | |
| (690 V) 40 kW | |
| (380 / 400 V) 37 kW | |
| (220 / 230 / 240 V) 22 kW | |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A | |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 1000 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Control Circuit Voltage (Uc) | DC Operation 20 ... 60 V |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 7 W |
| at Rated Operating Conditions AC-3 per Pole 2 W | |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715 | |
| Mounting by Screws (not supplied) | 2 x M6 Screws Placed Diagonally |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP10 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 | |
| Terminal Type | Ring-Tongue Terminals |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 105 A |
| Environmental | |
| Ambient Air Temperature | Close to Contactor for Storage -60 ... +80 °C |
| Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C | |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Shock and Vibration Withstand acc. to IEC 61373 | Category 1, Class B |
| Pollution Degree | 3 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 745659f1-0544-4b7d-836e-b14458224116 Bulgaria |
| Simplified SCIP | 008c8590-4eaf-42ca-97c8-3658e2baf8bb Spain |
| 134d9f04-8c4f-4e11-bec2-59c733e8f5e2 Sweden | |
| 1d5fd1cc-0f74-4c09-a30a-75c281b01c39 Finland | |
| 2d421100-bcf7-4eb6-8f77-9226a3dabedd Czech Republic | |
| 38ce0c56-1b4e-4b9b-8c52-54010f839460 Germany | |
| 474bd560-2118-4573-a3d4-2aff73c4b97a Portugal | |
| 5426b6a4-ca3a-41d7-96bc-45ee1c07847a Greece | |
| 5b669597-fe3e-4d54-aeb6-060519428ccf Estonia | |
| 5f8c9c6a-84c5-470c-9f05-b0d5ad74bbde Norway | |
| 73e66c99-f534-4304-9fea-400c601a1b45 Hungary | |
| 797e6b4c-3d7b-4a3d-9968-55af8e3116c7 Belgium | |
| 92e95d63-941e-4e55-8ca9-a8277c087b74 Poland | |
| 9370069b-fd1e-4549-b5b6-207264c3b255 Netherlands | |
| 96e33511-ee4e-4421-8525-16e5dab5e21d Denmark | |
| 9b842aee-e89d-41aa-b9ad-0367c6009a57 France | |
| b7c5b4a5-66d5-4419-b76c-3cb37a23ff84 Italy | |
| d84c8588-d0af-446a-9d50-3f625b055b35 Croatia | |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| Certificates and Declarations | |
| CCC Certificate | CCC_2018010304134049 |
| CQC Certificate | CQC2018010304134049 |
| CQC2010010304402983 | |
| Declaration of Conformity - CCC | 2020980304001624 |
| 2020980304001225 | |
| Declaration of Conformity - CE | 1SBD250803U1000 |
| Declaration of Conformity - UKCA | 1SBD250820U1000 |
| GOST Certificate | GOST_POCCFRME77B07175 |
| UL Certificate | UL-US-L312527-291-50119991-3 |
| UL-CA-2305459-0 | |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 142 mm |
| Package Level 1 Depth / Length | 190 mm |
| Package Level 1 Height | 136 mm |
| Package Level 1 Gross Weight | 1.42 kg |
| Package Level 1 EAN | 3471522245526 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE MOTOR PROTECTION EN.pdf | 240 Mbytes |
|
| AF75-40-00RT 20-60V DC Contactor - ABB - AF75-40-00RT - 1SBL417210R7200 | 87 Kbytes |
![]() |
| AF75-40-00RT 1SBL417210R7200 ABB AF75-40-00RT 20-60V DC Contactor | 90 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.