AF75-30-11 20-60V DC Contactor
Service Breakers
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SNC001003C0202 |
| Instructions and Manuals | FPTC407734P0003 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 82 mm |
| Product Net Depth / Length | 108 mm |
| Product Net Height | 110 mm |
| Product Net Weight | 1.22 kg |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011 (on request), IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives. |
| Rated Operational Voltage | Auxiliary Circuit 690 V |
| Main Circuit 690 V | |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
| Main Circuit 50 / 60 Hz | |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A |
| acc. to IEC 60947-5-1, Θ = 40 °C 16 A | |
| Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 125 A |
| (690 V) 55 °C 105 A | |
| (690 V) 70 °C 85 A | |
| Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 72 A |
| (440 V) 55 °C 70 A | |
| (500 V) 55 °C 65 A | |
| (690 V) 55 °C 46 A | |
| (380 / 400 V) 55 °C 75 A | |
| (220 / 230 / 240 V) 55 °C 75 | |
| Rated Operational Current AC-15 (Ie) | (500 V) 2 A |
| (690 V) 2 A | |
| (24 / 127 V) 6 A | |
| (220 / 240 V) 4 A | |
| (380 / 400 V) 3 A | |
| Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 40 °C 120 A |
| (110 V) 2 Poles in Series, 55 °C 105 A | |
| (110 V) 2 Poles in Series, 70 °C 85 A | |
| (110 V) 3 Poles in Series, 40 °C 120 A | |
| (110 V) 3 Poles in Series, 55 °C 105 A | |
| (110 V) 3 Poles in Series, 70 °C 85 A | |
| (220 V) 3 Poles in Series, 40 °C 120 A | |
| (220 V) 3 Poles in Series, 55 °C 105 A | |
| (220 V) 3 Poles in Series, 70 °C 85 A | |
| (72 V) 1-Pole, 40 °C 120 A | |
| (72 V) 1-Pole, 55 °C 105 A | |
| (72 V) 1-Pole, 70 °C 85 A | |
| (72 V) 2 Poles in Series, 40 °C 120 A | |
| (72 V) 2 Poles in Series, 55 °C 105 A | |
| (72 V) 2 Poles in Series, 70 °C 85 A | |
| (72 V) 3 Poles in Series, 40 °C 120 A | |
| (72 V) 3 Poles in Series, 55 °C 105 A | |
| (72 V) 3 Poles in Series, 70 °C 85 A | |
| Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 40 °C 120 A |
| (110 V) 2 Poles in Series, 55 °C 105 A | |
| (110 V) 2 Poles in Series, 70 °C 85 A | |
| (110 V) 3 Poles in Series, 40 °C 120 A | |
| (110 V) 3 Poles in Series, 55 °C 105 A | |
| (110 V) 3 Poles in Series, 70 °C 85 A | |
| (220 V) 3 Poles in Series, 40 °C 120 A | |
| (220 V) 3 Poles in Series, 55 °C 105 A | |
| (220 V) 3 Poles in Series, 70 °C 85 A | |
| (72 V) 1-Pole, 40 °C 120 A | |
| (72 V) 1-Pole, 55 °C 105 A | |
| (72 V) 1-Pole, 70 °C 85 A | |
| (72 V) 2 Poles in Series, 40 °C 120 A | |
| (72 V) 2 Poles in Series, 55 °C 105 A | |
| (72 V) 2 Poles in Series, 70 °C 85 A | |
| (72 V) 3 Poles in Series, 40 °C 120 A | |
| (72 V) 3 Poles in Series, 55 °C 105 A | |
| (72 V) 3 Poles in Series, 70 °C 85 A | |
| Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 40 °C 100 A |
| (110 V) 2 Poles in Series, 55 °C 100 A | |
| (110 V) 2 Poles in Series, 70 °C 85 A | |
| (110 V) 3 Poles in Series, 40 °C 120 A | |
| (110 V) 3 Poles in Series, 55 °C 105 A | |
| (110 V) 3 Poles in Series, 70 °C 85 A | |
| (220 V) 3 Poles in Series, 40 °C 75 A | |
| (220 V) 3 Poles in Series, 55 °C 75 A | |
| (220 V) 3 Poles in Series, 70 °C 75 A | |
| (72 V) 1-Pole, 40 °C 75 A | |
| (72 V) 1-Pole, 55 °C 75 A | |
| (72 V) 1-Pole, 70 °C 75 A | |
| (72 V) 2 Poles in Series, 40 °C 120 A | |
| (72 V) 2 Poles in Series, 55 °C 105 A | |
| (72 V) 2 Poles in Series, 70 °C 85 A | |
| (72 V) 3 Poles in Series, 40 °C 120 A | |
| (72 V) 3 Poles in Series, 55 °C 105 A | |
| (72 V) 3 Poles in Series, 70 °C 85 A | |
| Rated Operational Current DC-13 (Ie) | (24 V) 6 A / 144 W |
| (48 V) 2.8 A / 134 W | |
| (72 V) 1 A / 72 W | |
| (110 V) 0.55 A / 60 W | |
| (125 V) 0.55 A / 69 W | |
| (220 V) 0.30 A / 66 W | |
| (250 V) 0.3 / 75 W | |
| Rated Operational Power AC-3 (Pe) | (415 V) 40 kW |
| (440 V) 40 kW | |
| (500 V) 45 kW | |
| (690 V) 40 kW | |
| (380 / 400 V) 37 kW | |
| (220 / 230 / 240 V) 22 kW | |
| Rated Operational Power AC-6b (Pe) | (230 / 240 V) 40 °C, 50 / 60 Hz 28 kvar |
| (230 / 240 V) 55 °C, 50 / 60 Hz 28 kvar | |
| (230 / 240 V) 70 °C, 50 / 60 Hz 24.5 kvar | |
| (400 / 415 V) 40 °C, 50 / 60 Hz 48 kvar | |
| (400 / 415 V) 70 °C, 50 / 60 Hz 41 kvar | |
| (400 / 415 V) 55 °C, 50 / 60 Hz 48 kvar | |
| (440 V) 40 °C, 50 / 60 Hz 52 kvar | |
| (440 V) 55 °C, 50 / 60 Hz 52 kvar | |
| (440 V) 70 °C, 50 / 60 Hz 45 kvar | |
| (500 / 550 V), 40 °C, 50 / 60 Hz 60 kvar | |
| (500 / 550 V) 55 °C, 50 / 60 Hz 60 kvar | |
| (500 / 550 V) 70 °C, 50 / 60 Hz 51 kvar | |
| (690 V) 40 °C, 50 / 60 Hz 82 kvar | |
| (690 V) 55 °C, 50 / 60 Hz 82 kvar | |
| (690 V) 70 °C, 50 / 60 Hz 70 kvar | |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Short-Circuit Protective Devices | Auxiliary Circuit - gG Type Fuses 10 A |
| gG Type Fuses 160 A | |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A | |
| for 0.1 s 140 A | |
| for 1 s 100 A | |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 1000 V |
| acc. to IEC 60947-5-1 690 V | |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| (AC-2 / AC-4) 150 cycles per hour | |
| (AC-3) 300 cycles per hour | |
| Mechanical Durability | 10 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Minimum Switching Capacity | 17 / 5 VLT4K |
| Rated Control Circuit Voltage (Uc) | DC Operation 20 ... 60 V |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A |
| Holding at Max. Rated Control Circuit Voltage 50 Hz 2.8 W | |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A | |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 2.8 W | |
| Pull-in at Max. Rated Control Circuit Voltage 50 Hz 210 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 60 Hz 210 V·A | |
| Power Loss | at Rated Operating Conditions per Pole 0.1 W |
| at 6 A per Pole 0.1 W | |
| at Rated Operating Conditions AC-1 per Pole 7 W | |
| at Rated Operating Conditions AC-3 per Pole 2 W | |
| Operate Time | Between Coil De-energization and NC Contact Closing 35 ... 115 ms |
| Between Coil De-energization and NO Contact Opening 30 ... 110 ms | |
| Between Coil Energization and NC Contact Opening 27 ... 95 ms | |
| Between Coil Energization and NO Contact Closing 30 ... 100 ms | |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715 | |
| Mounting by Screws (not supplied) | 2 x M6 Screws Placed Diagonally |
| Connecting Capacity Main Circuit | Flexible with Cable End 6 ... 16 mm² |
| Rigid Cable 6 ... 25 mm² | |
| Connecting Capacity Auxiliary Circuit | Flexible with Cable End 0.75 ... 2.5 mm² |
| Rigid Cable 1 ... 4 mm² | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 | |
| Connecting Terminals (delivered in open position) Main Poles | M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| NEMA Size | 3 |
| Continuous Current Rating NEMA | 90 A |
| Horsepower Rating NEMA | (200 V AC) Three Phase 25 Hp |
| (230 V AC) Three Phase 30 Hp | |
| (460 V AC) Three Phase 50 Hp | |
| (575 V AC) Three Phase 50 Hp | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 105 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 7-1/2 hp |
| (200 ... 208 V AC) Three Phase 25 hp | |
| (220 ... 240 V AC) Three Phase 30 hp | |
| (240 V AC) Single Phase 15 hp | |
| (440 ... 480 V AC) Three Phase 60 hp | |
| (550 ... 600 V AC) Three Phase 75 hp | |
| Full Load Amps Motor Use | (120 V AC) Single Phase 80 A |
| (200 ... 208 V AC) Three Phase 78.2 A | |
| (220 ... 240 V AC) Three Phase 80 A | |
| (240 V AC) Single Phase 68 A | |
| (440 ... 480 V AC) Three Phase 77 A | |
| (550 ... 600 V AC) Three Phase 77 A | |
| Environmental | |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C |
| Close to Contactor without Thermal O/L Relay -40 ... 70 °C | |
| Close to Contactor for Storage -60 ... +80 °C | |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Shock and Vibration Withstand acc. to IEC 61373 | Category 1, Class B |
| Pollution Degree | 3 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 347cfd9f-3dc2-4e3e-a12a-4169c0a56bed China |
| Simplified SCIP | 0b9320fb-c470-41a9-a59b-fb3bd2a1a748 Greece |
| 11aea66b-25be-43f0-ba73-5d21bc37d7a6 Hungary | |
| 18e611c0-7b14-45d6-aa8f-23d5657488a1 Sweden | |
| 1c97db07-210e-41ac-92f0-cfd194d2247b Germany | |
| 2c1b08cc-b1f8-446e-9ef7-f1c444bf18d4 Netherlands | |
| 5f27d99e-ec0f-4ecd-975a-af18e8f78d3e Belgium | |
| 76640efa-53e9-43bc-8e41-eeffc31a0dbb Denmark | |
| 7f831c2f-6bac-4851-86ca-3c8862bff027 Estonia | |
| 820ac5d3-c6a8-4d18-8dde-78461c0e8cd3 Portugal | |
| 8fa163f8-a964-4c85-be08-74b174a11ced France | |
| c1d40e02-c10d-4a1c-81f4-c008b32ed7a3 Spain | |
| cd2cb7bb-307d-4ad4-a3db-cda08e044b57 Poland | |
| d001de39-0ced-4f07-8155-97930aef81cd Czech Republic | |
| d0347b9c-c79e-47d4-90d4-56a612d1c079 Norway | |
| e622fd29-c30d-4d38-a404-0d1c3eab41a9 Finland | |
| ebbae948-a814-4ddb-a331-814cbdf1a51e Croatia | |
| f7783725-cd93-41e4-9e41-07c6ef31ef63 Bulgaria | |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| Certificates and Declarations | |
| CB Certificate | CB_CN45489 |
| CCC Certificate | CCC_2018010304134049 |
| CCC_2010010304402983 | |
| CQC Certificate | CQC2018010304134049 |
| CQC2010010304402983 | |
| Declaration of Conformity - CCC | 2020980304001624 |
| 2020980304001225 | |
| Declaration of Conformity - CE | 1SBD250803U1000 |
| Declaration of Conformity - UKCA | 1SBD250820U1000 |
| GOST Certificate | GOST_POCCFRME77B07175 |
| KC Certificate | KC_HW02032-21002B |
| LOVAG Certificate | LOVAG_FR04002 |
| RMRS Certificate | RMRS_1802704280 |
| UL Certificate | UL-US-L312527-1101-21215991-6 |
| UL-CA-2139468-4 | |
| UL Listing Card | UL_E312527 |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 140 mm |
| Package Level 1 Depth / Length | 146 mm |
| Package Level 1 Height | 96 mm |
| Package Level 1 Gross Weight | 1.22 kg |
| Package Level 1 EAN | 3471522115225 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4756 >> Capacitor magnet contactor |
| Title: | Size: | Type: |
|---|---|---|
| PDF CIRCUIT BREAKERS TMAX XT.pdf | 26 Mbytes |
|
| AF75-30-11 20-60V DC Contactor - ABB - AF75-30-11 - 1SBL417001R7211 | 99 Kbytes |
![]() |
| AF75-30-11 1SBL417001R7211 ABB AF75-30-11 20-60V DC Contactor | 84 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.