Product successfully added to your shopping cart
AF75-30-00RT
1SBL417010R7200
ABB
1
AF75-30-00RT 20-60V DC Contactor
Service Breakers > Terminals and accessories railway applications
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SNC001003C0202 |
| Instructions and Manuals | FPTC407767P0002 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 70 mm |
| Product Net Depth / Length | 108 mm |
| Product Net Height | 110 mm |
| Product Net Weight | 1.18 kg |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011 (on request), IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives. |
| Rated Operational Voltage | Main Circuit 690 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 125 A |
| (690 V) 55 °C 105 A | |
| (690 V) 70 °C 85 A | |
| Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 72 A |
| (440 V) 55 °C 70 A | |
| (500 V) 55 °C 65 A | |
| (690 V) 55 °C 46 A | |
| (380 / 400 V) 55 °C 75 A | |
| (220 / 230 / 240 V) 55 °C 75 | |
| Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 40 °C 120 A |
| (110 V) 2 Poles in Series, 55 °C 105 A | |
| (110 V) 2 Poles in Series, 70 °C 85 A | |
| (110 V) 3 Poles in Series, 40 °C 120 A | |
| (110 V) 3 Poles in Series, 55 °C 105 A | |
| (110 V) 3 Poles in Series, 70 °C 85 A | |
| (220 V) 3 Poles in Series, 40 °C 120 A | |
| (220 V) 3 Poles in Series, 55 °C 105 A | |
| (220 V) 3 Poles in Series, 70 °C 85 A | |
| (72 V) 1-Pole, 40 °C 120 A | |
| (72 V) 1-Pole, 55 °C 105 A | |
| (72 V) 1-Pole, 70 °C 85 A | |
| (72 V) 2 Poles in Series, 40 °C 120 A | |
| (72 V) 2 Poles in Series, 55 °C 105 A | |
| (72 V) 2 Poles in Series, 70 °C 85 A | |
| (72 V) 3 Poles in Series, 40 °C 120 A | |
| (72 V) 3 Poles in Series, 55 °C 105 A | |
| (72 V) 3 Poles in Series, 70 °C 85 A | |
| Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 40 °C 120 A |
| (110 V) 2 Poles in Series, 55 °C 105 A | |
| (110 V) 2 Poles in Series, 70 °C 85 A | |
| (110 V) 3 Poles in Series, 40 °C 120 A | |
| (110 V) 3 Poles in Series, 55 °C 105 A | |
| (110 V) 3 Poles in Series, 70 °C 85 A | |
| (220 V) 3 Poles in Series, 40 °C 120 A | |
| (220 V) 3 Poles in Series, 55 °C 105 A | |
| (220 V) 3 Poles in Series, 70 °C 85 A | |
| (72 V) 1-Pole, 40 °C 120 A | |
| (72 V) 1-Pole, 55 °C 105 A | |
| (72 V) 1-Pole, 70 °C 85 A | |
| (72 V) 2 Poles in Series, 40 °C 120 A | |
| (72 V) 2 Poles in Series, 55 °C 105 A | |
| (72 V) 2 Poles in Series, 70 °C 85 A | |
| (72 V) 3 Poles in Series, 40 °C 120 A | |
| (72 V) 3 Poles in Series, 55 °C 105 A | |
| (72 V) 3 Poles in Series, 70 °C 85 A | |
| Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 40 °C 100 A |
| (110 V) 2 Poles in Series, 55 °C 100 A | |
| (110 V) 2 Poles in Series, 70 °C 85 A | |
| (110 V) 3 Poles in Series, 40 °C 120 A | |
| (110 V) 3 Poles in Series, 55 °C 105 A | |
| (110 V) 3 Poles in Series, 70 °C 85 A | |
| (220 V) 3 Poles in Series, 40 °C 75 A | |
| (220 V) 3 Poles in Series, 55 °C 75 A | |
| (220 V) 3 Poles in Series, 70 °C 75 A | |
| (72 V) 1-Pole, 40 °C 75 A | |
| (72 V) 1-Pole, 55 °C 75 A | |
| (72 V) 1-Pole, 70 °C 75 A | |
| (72 V) 2 Poles in Series, 40 °C 120 A | |
| (72 V) 2 Poles in Series, 55 °C 105 A | |
| (72 V) 2 Poles in Series, 70 °C 85 A | |
| (72 V) 3 Poles in Series, 40 °C 120 A | |
| (72 V) 3 Poles in Series, 55 °C 105 A | |
| (72 V) 3 Poles in Series, 70 °C 85 A | |
| Rated Operational Power AC-3 (Pe) | (415 V) 40 kW |
| (440 V) 40 kW | |
| (500 V) 45 kW | |
| (690 V) 40 kW | |
| (380 / 400 V) 37 kW | |
| (220 / 230 / 240 V) 22 kW | |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A | |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 1000 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Control Circuit Voltage (Uc) | DC Operation 20 ... 60 V |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 7 W |
| at Rated Operating Conditions AC-3 per Pole 2 W | |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715 | |
| Mounting by Screws (not supplied) | 2 x M6 Screws Placed Diagonally |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP10 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 | |
| Terminal Type | Ring-Tongue Terminals |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| NEMA Size | 3 |
| Continuous Current Rating NEMA | 90 A |
| Horsepower Rating NEMA | (200 V AC) Three Phase 25 Hp |
| (230 V AC) Three Phase 30 Hp | |
| (460 V AC) Three Phase 50 Hp | |
| (575 V AC) Three Phase 50 Hp | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 105 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 7-1/2 hp |
| (200 ... 208 V AC) Three Phase 25 hp | |
| (220 ... 240 V AC) Three Phase 30 hp | |
| (240 V AC) Single Phase 15 hp | |
| (440 ... 480 V AC) Three Phase 60 hp | |
| (550 ... 600 V AC) Three Phase 75 hp | |
| Full Load Amps Motor Use | (120 V AC) Single Phase 80 A |
| (200 ... 208 V AC) Three Phase 78.2 A | |
| (220 ... 240 V AC) Three Phase 80 A | |
| (240 V AC) Single Phase 68 A | |
| (440 ... 480 V AC) Three Phase 77 A | |
| (550 ... 600 V AC) Three Phase 77 A | |
| Environmental | |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C |
| Close to Contactor without Thermal O/L Relay -40 ... 70 °C | |
| Close to Contactor for Storage -60 ... +80 °C | |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Shock and Vibration Withstand acc. to IEC 61373 | Category 1, Class B |
| Pollution Degree | 3 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | e1c82318-174d-4518-988a-8692aab7e9b3 Bulgaria |
| Simplified SCIP | 0361e5c3-fde4-49d3-9c58-f47e761aac01 Spain |
| 03a4db81-d906-4972-8493-0b90c299fb0e Sweden | |
| 04a270bc-1430-4e5b-9140-870ae1faa3ec Portugal | |
| 1462c705-189a-4d0c-a5af-76d82df09cc3 Denmark | |
| 1b884458-a255-4752-a472-0b6337de9719 Italy | |
| 31489b16-22f2-451a-a673-e3c8567fcbdf Finland | |
| 58d10d66-7691-4102-a80c-80d19a39148c Netherlands | |
| 5bb0cf3a-87b8-46cf-aec8-bf69d77fb2e6 France | |
| 7139508e-3511-4a1a-8380-24017fa84bc7 Greece | |
| 76d25881-943c-4d5a-85fe-b852380f5550 Estonia | |
| 97de07c2-3434-4e76-9173-1ae147badd13 Croatia | |
| abf1860b-745d-40d6-943b-2816db213e55 Norway | |
| c96f464e-87b6-44b0-9626-917ed71780a4 Hungary | |
| cdbaa4f3-2974-40f5-ab25-f525b9d171e5 Germany | |
| d47eed24-d156-4082-bb02-82a6edb79916 Poland | |
| da3a1d31-b882-4355-b74d-38ca779227df Belgium | |
| dee0a92d-3625-4b25-93bf-af7561e273bb Czech Republic | |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| Certificates and Declarations | |
| CCC Certificate | CCC_2018010304134049 |
| CQC Certificate | CQC2018010304134049 |
| CQC2010010304402983 | |
| Declaration of Conformity - CCC | 2020980304001624 |
| 2020980304001225 | |
| Declaration of Conformity - CE | 1SBD250803U1000 |
| Declaration of Conformity - UKCA | 1SBD250820U1000 |
| GOST Certificate | GOST_POCCFRME77B07175 |
| KC Certificate | KC_HW02032-21002B |
| UL Certificate | UL-US-L312527-291-50119991-3 |
| UL-CA-2305459-0 | |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 140 mm |
| Package Level 1 Depth / Length | 146 mm |
| Package Level 1 Height | 96 mm |
| Package Level 1 Gross Weight | 1.18 kg |
| Package Level 1 EAN | 3471522245328 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4756 >> Capacitor magnet contactor |
| Title: | Size: | Type: |
|---|---|---|
| PDF CIRCUIT BREAKERS TMAX XT.pdf | 26 Mbytes |
|
| AF75-30-00RT 20-60V DC Contactor - ABB - AF75-30-00RT - 1SBL417010R7200 | 86 Kbytes |
![]() |
| AF75-30-00RT 1SBL417010R7200 ABB AF75-30-00RT 20-60V DC Contactor | 84 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.