AF50-40-00 1SBL357201R7200 ABB AF50-40-00 20-60V DC Contactor View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

AF50-40-00 1SBL357201R7200 ABB AF50-40-00 20-60V DC Contactor

AF50-40-00

1SBL357201R7200

ABB

AF50-40-00 20-60V DC Contactor

More details


Contactors and overload relays > Contactors "A" FRCTLP

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information1SNC001003C0202
Instructions and ManualsFPTC407734P0003
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width92 mm
Product Net Depth / Length119.5 mm
Product Net Height110 mm
Product Net Weight1.42 kg
Technical
Number of Main Contacts NO4
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
Number of Poles4P
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011 (on request), IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational VoltageMain Circuit 690 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 100 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 100 A
(690 V) 55 °C 85 A
(690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 50 A
(440 V) 55 °C 45 A
(500 V) 55 °C 45 A
(690 V) 55 °C 35 A
(380 / 400 V) 55 °C 50 A
(220 / 230 / 240 V) 55 °C 53
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 55 °C 85 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 55 °C 85 A
(110 V) 3 Poles in Series, 70 °C 70 A
(110 V) 4 Poles in Series, 40 °C 100 A
(110 V) 4 Poles in Series, 55 °C 85 A
(110 V) 4 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 55 °C 85 A
(220 V) 3 Poles in Series, 70 °C 70 A
(220 V) 4 Poles in Series, 40 °C 100 A
(220 V) 4 Poles in Series, 55 °C 85 A
(220 V) 4 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
(72 V) 1-Pole, 55 °C 85 A
(72 V) 1-Pole, 70 °C 70 A
(72 V) 2 Poles in Series, 40 °C 100 A
(72 V) 2 Poles in Series, 55 °C 85 A
(72 V) 2 Poles in Series, 70 °C 70 A
(72 V) 3 Poles in Series, 40 °C 100 A
(72 V) 3 Poles in Series, 55 °C 85 A
(72 V) 3 Poles in Series, 70 °C 70 A
(72 V) 4 Poles in Series, 40 °C 100 A
(72 V) 4 Poles in Series, 55 °C 85 A
(72 V) 4 Poles in Series, 70 °C 70 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 55 °C 85 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 55 °C 85 A
(110 V) 3 Poles in Series, 70 °C 70 A
(110 V) 4 Poles in Series, 40 °C 100 A
(110 V) 4 Poles in Series, 55 °C 85 A
(110 V) 4 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 55 °C 85 A
(220 V) 3 Poles in Series, 70 °C 70 A
(220 V) 4 Poles in Series, 40 °C 100 A
(220 V) 4 Poles in Series, 55 °C 85 A
(220 V) 4 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
(72 V) 1-Pole, 55 °C 85 A
(72 V) 1-Pole, 70 °C 70 A
(72 V) 2 Poles in Series, 40 °C 100 A
(72 V) 2 Poles in Series, 55 °C 85 A
(72 V) 2 Poles in Series, 70 °C 70 A
(72 V) 3 Poles in Series, 40 °C 100 A
(72 V) 3 Poles in Series, 55 °C 85 A
(72 V) 3 Poles in Series, 70 °C 70 A
(72 V) 4 Poles in Series, 40 °C 100 A
(72 V) 4 Poles in Series, 55 °C 85 A
(72 V) 4 Poles in Series, 70 °C 70 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 80 A
(110 V) 2 Poles in Series, 55 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 55 °C 85 A
(110 V) 3 Poles in Series, 70 °C 70 A
(110 V) 4 Poles in Series, 40 °C 100 A
(110 V) 4 Poles in Series, 55 °C 85 A
(110 V) 4 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 50 A
(220 V) 3 Poles in Series, 55 °C 50 A
(220 V) 3 Poles in Series, 70 °C 50 A
(220 V) 4 Poles in Series, 40 °C 70 A
(220 V) 4 Poles in Series, 55 °C 70 A
(220 V) 4 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 50 A
(72 V) 1-Pole, 55 °C 50 A
(72 V) 1-Pole, 70 °C 50 A
(72 V) 2 Poles in Series, 40 °C 100 A
(72 V) 2 Poles in Series, 55 °C 85 A
(72 V) 2 Poles in Series, 70 °C 70 A
(72 V) 3 Poles in Series, 40 °C 100 A
(72 V) 3 Poles in Series, 55 °C 85 A
(72 V) 3 Poles in Series, 70 °C 70 A
(72 V) 4 Poles in Series, 40 °C 100 A
(72 V) 4 Poles in Series, 55 °C 85 A
(72 V) 4 Poles in Series, 70 °C 70 A
Rated Operational Power AC-3 (Pe)(415 V) 25 kW
(440 V) 25 kW
(500 V) 30 kW
(690 V) 30 kW
(380 / 400 V) 22 kW
(220 / 230 / 240 V) 15 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Short-Circuit Protective DevicesgG Type Fuses 100 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)8 kV
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
Mechanical Durability10 million
Maximum Mechanical Switching Frequency300 cycles per hour
Rated Control Circuit Voltage (Uc)DC Operation 20 ... 60 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 2.8 W
Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 2.8 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 210 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 210 V·A
Power Lossat Rated Operating Conditions per Pole 1.3 W
at Rated Operating Conditions AC-1 per Pole 5 W
at Rated Operating Conditions AC-3 per Pole 1.3 W
Operate TimeBetween Coil De-energization and NC Contact Closing 35 ... 115 ms
Between Coil De-energization and NO Contact Opening 30 ... 110 ms
Between Coil Energization and NO Contact Closing 30 ... 100 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) 2 x M6 Screws Placed Diagonally
Connecting Capacity Main CircuitFlexible with Cable End 6 ... 16 mm²
Rigid Cable 6 ... 25 mm²
Connecting Capacity Auxiliary CircuitFlexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main PolesM 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector
Terminal TypeScrew Terminals
Product NameBlock Contactor
Technical UL/CSA
Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 80 A
Environmental
Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstandaccording to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Closed, Shock Direction: B1 10 g
Open, Shock Direction: B1 5 g
Shock Direction: A 20 g
Shock Direction: B2 15 g
Shock Direction: C1 20 g
Shock Direction: C2 20 g
Shock and Vibration Withstand acc. to IEC 61373Category 1, Class B
Pollution Degree3
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIPa13ed6ce-0106-4625-b487-584bb02782ca Bulgaria
Simplified SCIP01648703-73a2-4e54-b2c1-b3d834cc24ab Italy
0c929d69-2a56-47aa-be88-2f9d220f3066 Spain
25dc54d3-62c6-418e-9bf5-f5ee3552dff6 Poland
314c0cec-d83f-442f-9a0b-d31333c7b3df Denmark
3bf8e1d8-40fd-48de-b9df-fec4f87d48f3 Finland
545c5cb9-fa78-48b0-ac96-6a7576ddc6a0 Croatia
54dc6254-c104-48a1-90d5-e289a9bcdddb Netherlands
5540a660-3320-4e57-bcb0-e864b52e3f5d Germany
6031d3a9-5e3a-419a-9270-08fa4025549e Norway
6183a8ba-a505-49ba-b164-d5478796574f Hungary
6a1c0863-cdc5-4c8d-9b95-fc75085583e1 Estonia
818fb759-cbf0-4744-9efd-b926bae2f868 Belgium
8d2d2a34-129f-4066-a41d-37cc07d341a6 Sweden
ba74b7d5-7314-484f-8071-97c936d67765 France
e105553e-bf75-42be-82c0-027a0358c4ad Czech Republic
ebc632bc-8c6c-43dc-ad7b-b157b20896a5 Portugal
fe7ef22b-b5f6-4c32-ba29-30fca05d3c44 Greece
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
CB CertificateCB_CN45489
CCC CertificateCCC_2018010304134049
CQC CertificateCQC2018010304134049
CQC2010010304402983
CSA CertificateCSA_1033838_LR056745
Declaration of Conformity - CCC2020980304001624
2020980304001225
Declaration of Conformity - CE1SBD250803U1000
Declaration of Conformity - UKCA1SBD250820U1000
EAC CertificateEAC_RU C-FR ME77 B01010
GOST CertificateGOST_POCCFRME77B07175
UL CertificateUL_20120830-E312527-10-1
UL Listing CardUL_E312527
Container Information
Package Level 1 Units1 piece
Package Level 1 Width142 mm
Package Level 1 Depth / Length190 mm
Package Level 1 Height136 mm
Package Level 1 Gross Weight1.42 kg
Package Level 1 EAN3471522114822
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4760 >> Lighting Contactors

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.