Product successfully added to your shopping cart
AF50-30-00RT
1SBL357010R7200
ABB
1
AF50-30-00RT 20-60V DC Contactor
Contactors and overload relays > Contactors "A" Classic Range
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SNC001003C0202 |
| Instructions and Manuals | FPTC407767P0002 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 70 mm |
| Product Net Depth / Length | 108 mm |
| Product Net Height | 110 mm |
| Product Net Weight | 1.18 kg |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011 (on request), IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives. |
| Rated Operational Voltage | Main Circuit 690 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 100 A |
| (690 V) 55 °C 85 A | |
| (690 V) 70 °C 70 A | |
| Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 50 A |
| (440 V) 55 °C 45 A | |
| (500 V) 55 °C 45 A | |
| (690 V) 55 °C 35 A | |
| (380 / 400 V) 55 °C 50 A | |
| (220 / 230 / 240 V) 55 °C 53 | |
| Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 40 °C 100 A |
| (110 V) 2 Poles in Series, 55 °C 85 A | |
| (110 V) 2 Poles in Series, 70 °C 70 A | |
| (110 V) 3 Poles in Series, 40 °C 100 A | |
| (110 V) 3 Poles in Series, 55 °C 85 A | |
| (110 V) 3 Poles in Series, 70 °C 70 A | |
| (220 V) 3 Poles in Series, 40 °C 100 A | |
| (220 V) 3 Poles in Series, 55 °C 85 A | |
| (220 V) 3 Poles in Series, 70 °C 70 A | |
| (72 V) 1-Pole, 40 °C 100 A | |
| (72 V) 1-Pole, 55 °C 85 A | |
| (72 V) 1-Pole, 70 °C 70 A | |
| (72 V) 2 Poles in Series, 40 °C 100 A | |
| (72 V) 2 Poles in Series, 55 °C 85 A | |
| (72 V) 2 Poles in Series, 70 °C 70 A | |
| (72 V) 3 Poles in Series, 40 °C 100 A | |
| (72 V) 3 Poles in Series, 55 °C 85 A | |
| (72 V) 3 Poles in Series, 70 °C 70 A | |
| Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 40 °C 100 A |
| (110 V) 2 Poles in Series, 55 °C 85 A | |
| (110 V) 2 Poles in Series, 70 °C 70 A | |
| (110 V) 3 Poles in Series, 40 °C 100 A | |
| (110 V) 3 Poles in Series, 55 °C 85 A | |
| (110 V) 3 Poles in Series, 70 °C 70 A | |
| (220 V) 3 Poles in Series, 40 °C 100 A | |
| (220 V) 3 Poles in Series, 55 °C 85 A | |
| (220 V) 3 Poles in Series, 70 °C 70 A | |
| (72 V) 1-Pole, 40 °C 100 A | |
| (72 V) 1-Pole, 55 °C 85 A | |
| (72 V) 1-Pole, 70 °C 70 A | |
| (72 V) 2 Poles in Series, 40 °C 100 A | |
| (72 V) 2 Poles in Series, 55 °C 85 A | |
| (72 V) 2 Poles in Series, 70 °C 70 A | |
| (72 V) 3 Poles in Series, 40 °C 100 A | |
| (72 V) 3 Poles in Series, 55 °C 85 A | |
| (72 V) 3 Poles in Series, 70 °C 70 A | |
| Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 40 °C 80 A |
| (110 V) 2 Poles in Series, 55 °C 80 A | |
| (110 V) 2 Poles in Series, 70 °C 70 A | |
| (110 V) 3 Poles in Series, 40 °C 100 A | |
| (110 V) 3 Poles in Series, 55 °C 85 A | |
| (110 V) 3 Poles in Series, 70 °C 70 A | |
| (220 V) 3 Poles in Series, 40 °C 50 A | |
| (220 V) 3 Poles in Series, 55 °C 50 A | |
| (220 V) 3 Poles in Series, 70 °C 50 A | |
| (72 V) 1-Pole, 40 °C 50 A | |
| (72 V) 1-Pole, 55 °C 50 A | |
| (72 V) 1-Pole, 70 °C 50 A | |
| (72 V) 2 Poles in Series, 40 °C 100 A | |
| (72 V) 2 Poles in Series, 55 °C 85 A | |
| (72 V) 2 Poles in Series, 70 °C 70 A | |
| (72 V) 3 Poles in Series, 40 °C 100 A | |
| (72 V) 3 Poles in Series, 55 °C 85 A | |
| (72 V) 3 Poles in Series, 70 °C 70 A | |
| Rated Operational Power AC-3 (Pe) | (415 V) 25 kW |
| (440 V) 25 kW | |
| (500 V) 30 kW | |
| (690 V) 30 kW | |
| (380 / 400 V) 22 kW | |
| (220 / 230 / 240 V) 15 kW | |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A | |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 1000 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Control Circuit Voltage (Uc) | DC Operation 20 ... 60 V |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 5 W |
| at Rated Operating Conditions AC-3 per Pole 1.3 W | |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715 | |
| Mounting by Screws (not supplied) | 2 x M6 Screws Placed Diagonally |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP10 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 | |
| Terminal Type | Ring-Tongue Terminals |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| NEMA Size | 2 |
| Continuous Current Rating NEMA | 45 A |
| Horsepower Rating NEMA | (115 V AC) Single Phase 3 Hp |
| (200 V AC) Three Phase 10 Hp | |
| (230 V AC) Single Phase 7-1/2 Hp | |
| (230 V AC) Three Phase 15 Hp | |
| (460 V AC) Three Phase 25 Hp | |
| (575 V AC) Three Phase 25 Hp | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 80 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 3 hp |
| (200 ... 208 V AC) Three Phase 15 Hp | |
| (220 ... 240 V AC) Three Phase 20 Hp | |
| (240 V AC) Single Phase 7-1/2 hp | |
| (440 ... 480 V AC) Three Phase 40 Hp | |
| (550 ... 600 V AC) Three Phase 50 Hp | |
| Full Load Amps Motor Use | (120 V AC) Single Phase 34 A |
| (200 ... 208 V AC) Three Phase 48.3 A | |
| (220 ... 240 V AC) Three Phase 54 A | |
| (240 V AC) Single Phase 40 A | |
| (440 ... 480 V AC) Three Phase 52 A | |
| (550 ... 600 V AC) Three Phase 52 A | |
| Environmental | |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C |
| Close to Contactor without Thermal O/L Relay -40 ... 70 °C | |
| Close to Contactor for Storage -60 ... +80 °C | |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Shock and Vibration Withstand acc. to IEC 61373 | Category 1, Class B |
| Pollution Degree | 3 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 02bdfc18-3f3c-4676-b07d-1ca17fee8440 Bulgaria |
| Simplified SCIP | 0977de89-8ad8-4845-93a3-532ac3380f9e Poland |
| 15129761-15ec-4221-8fe2-f0582bf907b7 France | |
| 18ed9541-ef74-43c4-920f-4ba7ffa4e4ee Finland | |
| 1dc0dda7-7efa-4d32-b146-0c27d4b4addf Portugal | |
| 26b052dd-ce96-4476-ac00-0c77d7886137 Greece | |
| 316c0ff7-8f37-42c1-8ec1-80758fef5deb Italy | |
| 3bb90088-1ad4-4ad6-a104-a8a299db3220 Czech Republic | |
| 4b2a99b5-5663-4e30-9a62-ab6337901d3b Estonia | |
| 5a0cd3a3-028d-4918-8564-7e671ed785b5 Croatia | |
| 81788b1c-ef1c-4f07-98f2-4d3ce290d098 Spain | |
| 81858485-54e2-49c3-97f4-6a8083ade66c Sweden | |
| 95cab338-e993-438e-ac4e-7f44fb599e33 Netherlands | |
| b88e0181-868c-4558-8748-39b5f8616562 Norway | |
| be5642bd-6864-4671-b1d2-991d1206c88d Germany | |
| c94ee6bf-a9b9-490b-9d29-ed08b20c5b95 Denmark | |
| d96193fc-8b5b-450a-863f-11c8e2933af6 Belgium | |
| e3b8c470-be1a-400e-91da-be9dd27b49de Hungary | |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| Certificates and Declarations | |
| CCC Certificate | CCC_2018010304134049 |
| CQC Certificate | CQC2018010304134049 |
| CQC2010010304402983 | |
| Declaration of Conformity - CCC | 2020980304001624 |
| 2020980304001225 | |
| Declaration of Conformity - CE | 1SBD250803U1000 |
| Declaration of Conformity - UKCA | 1SBD250820U1000 |
| EAC Certificate | EAC_RU C-FR ME77 B01010 |
| GOST Certificate | GOST_POCCFRME77B07175 |
| KC Certificate | KC_HW02032-21001B |
| UL Certificate | UL-US-L312527-291-50119991-3 |
| UL-CA-2305459-0 | |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 140 mm |
| Package Level 1 Depth / Length | 146 mm |
| Package Level 1 Height | 96 mm |
| Package Level 1 Gross Weight | 1.18 kg |
| Package Level 1 EAN | 3471522245120 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4756 >> Capacitor magnet contactor |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE MOTOR PROTECTION EN.pdf | 240 Mbytes |
|
| AF50-30-00RT 20-60V DC Contactor - ABB - AF50-30-00RT - 1SBL357010R7200 | 87 Kbytes |
![]() |
| AF50-30-00RT 1SBL357010R7200 ABB AF50-30-00RT 20-60V DC Contactor | 88 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.