Product successfully added to your shopping cart
AF45-40-00RT
1SBL337210R7200
ABB
1
AF45-40-00RT 20-60V DC Contactor
Contactors and overload relays > Contactors "A" FRCTLP
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SNC001003C0202 |
| Instructions and Manuals | FPTC407767P0002 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 92 mm |
| Product Net Depth / Length | 119.5 mm |
| Product Net Height | 110 mm |
| Product Net Weight | 1.42 kg |
| Technical | |
| Number of Main Contacts NO | 4 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 4P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011 (on request), IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives. |
| Rated Operational Voltage | Main Circuit 690 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 70 A |
| (690 V) 55 °C 60 A | |
| (690 V) 60 °C 60 A | |
| (690 V) 70 °C 50 A | |
| Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 37 A |
| (440 V) 55 °C 37 A | |
| (500 V) 55 °C 33 A | |
| (690 V) 55 °C 21 A | |
| (380 / 400 V) 55 °C 37 A | |
| (220 / 230 / 240 V) 55 °C 40 | |
| Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 40 °C 70 A |
| (110 V) 2 Poles in Series, 55 °C 60 A | |
| (110 V) 2 Poles in Series, 70 °C 50 A | |
| (110 V) 3 Poles in Series, 40 °C 70 A | |
| (110 V) 3 Poles in Series, 55 °C 60 A | |
| (110 V) 3 Poles in Series, 70 °C 50 A | |
| (110 V) 4 Poles in Series, 40 °C 70 A | |
| (110 V) 4 Poles in Series, 55 °C 60 A | |
| (110 V) 4 Poles in Series, 70 °C 50 A | |
| (220 V) 3 Poles in Series, 40 °C 70 A | |
| (220 V) 3 Poles in Series, 55 °C 60 A | |
| (220 V) 3 Poles in Series, 70 °C 50 A | |
| (220 V) 4 Poles in Series, 40 °C 70 A | |
| (220 V) 4 Poles in Series, 55 °C 60 A | |
| (220 V) 4 Poles in Series, 70 °C 50 A | |
| (72 V) 1-Pole, 40 °C 70 A | |
| (72 V) 1-Pole, 55 °C 60 A | |
| (72 V) 1-Pole, 70 °C 50 A | |
| (72 V) 2 Poles in Series, 40 °C 70 A | |
| (72 V) 2 Poles in Series, 55 °C 60 A | |
| (72 V) 2 Poles in Series, 70 °C 50 A | |
| (72 V) 3 Poles in Series, 40 °C 70 A | |
| (72 V) 3 Poles in Series, 55 °C 60 A | |
| (72 V) 3 Poles in Series, 70 °C 50 A | |
| (72 V) 4 Poles in Series, 40 °C 70 A | |
| (72 V) 4 Poles in Series, 55 °C 60 A | |
| (72 V) 4 Poles in Series, 70 °C 50 A | |
| Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 40 °C 70 A |
| (110 V) 2 Poles in Series, 55 °C 60 A | |
| (110 V) 2 Poles in Series, 70 °C 50 A | |
| (110 V) 3 Poles in Series, 40 °C 70 A | |
| (110 V) 3 Poles in Series, 55 °C 60 A | |
| (110 V) 3 Poles in Series, 70 °C 50 A | |
| (110 V) 4 Poles in Series, 40 °C 70 A | |
| (110 V) 4 Poles in Series, 55 °C 60 A | |
| (110 V) 4 Poles in Series, 70 °C 50 A | |
| (220 V) 3 Poles in Series, 40 °C 70 A | |
| (220 V) 3 Poles in Series, 55 °C 60 A | |
| (220 V) 3 Poles in Series, 70 °C 50 A | |
| (220 V) 4 Poles in Series, 40 °C 70 A | |
| (220 V) 4 Poles in Series, 55 °C 60 A | |
| (220 V) 4 Poles in Series, 70 °C 50 A | |
| (72 V) 1-Pole, 40 °C 70 A | |
| (72 V) 1-Pole, 55 °C 60 A | |
| (72 V) 1-Pole, 70 °C 50 A | |
| (72 V) 2 Poles in Series, 40 °C 70 A | |
| (72 V) 2 Poles in Series, 55 °C 60 A | |
| (72 V) 2 Poles in Series, 70 °C 50 A | |
| (72 V) 3 Poles in Series, 40 °C 70 A | |
| (72 V) 3 Poles in Series, 55 °C 60 A | |
| (72 V) 3 Poles in Series, 70 °C 50 A | |
| (72 V) 4 Poles in Series, 40 °C 70 A | |
| (72 V) 4 Poles in Series, 55 °C 60 A | |
| (72 V) 4 Poles in Series, 70 °C 50 A | |
| Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 40 °C 70 A |
| (110 V) 2 Poles in Series, 55 °C 60 A | |
| (110 V) 2 Poles in Series, 70 °C 50 A | |
| (110 V) 3 Poles in Series, 40 °C 70 A | |
| (110 V) 3 Poles in Series, 55 °C 60 A | |
| (110 V) 3 Poles in Series, 70 °C 50 A | |
| (110 V) 4 Poles in Series, 40 °C 70 A | |
| (110 V) 4 Poles in Series, 55 °C 60 A | |
| (110 V) 4 Poles in Series, 70 °C 50 A | |
| (220 V) 3 Poles in Series, 40 °C 50 A | |
| (220 V) 3 Poles in Series, 55 °C 50 A | |
| (220 V) 3 Poles in Series, 70 °C 50 A | |
| (220 V) 4 Poles in Series, 40 °C 70 A | |
| (220 V) 4 Poles in Series, 55 °C 60 A | |
| (220 V) 4 Poles in Series, 70 °C 50 A | |
| (72 V) 1-Pole, 40 °C 50 A | |
| (72 V) 1-Pole, 55 °C 50 A | |
| (72 V) 1-Pole, 70 °C 50 A | |
| (72 V) 2 Poles in Series, 40 °C 70 A | |
| (72 V) 2 Poles in Series, 55 °C 60 A | |
| (72 V) 2 Poles in Series, 70 °C 50 A | |
| (72 V) 3 Poles in Series, 40 °C 70 A | |
| (72 V) 3 Poles in Series, 55 °C 60 A | |
| (72 V) 3 Poles in Series, 70 °C 50 A | |
| (72 V) 4 Poles in Series, 40 °C 70 A | |
| (72 V) 4 Poles in Series, 55 °C 60 A | |
| (72 V) 4 Poles in Series, 70 °C 50 A | |
| Rated Operational Power AC-3 (Pe) | (415 V) 25 kW |
| (440 V) 25 kW | |
| (500 V) 30 kW | |
| (690 V) 30 kW | |
| (380 / 400 V) 22 kW | |
| (220 / 230 / 240 V) 15 kW | |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A | |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 900 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 490 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 1000 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Control Circuit Voltage (Uc) | DC Operation 20 ... 60 V |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 2.5 W |
| at Rated Operating Conditions AC-3 per Pole 0.65 W | |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715 | |
| Mounting by Screws (not supplied) | 2 x M6 Screws Placed Diagonally |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP10 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 | |
| Terminal Type | Ring-Tongue Terminals |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 80 A |
| Environmental | |
| Ambient Air Temperature | Close to Contactor for Storage -60 ... +80 °C |
| Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C | |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Shock and Vibration Withstand acc. to IEC 61373 | Category 1, Class B |
| Pollution Degree | 3 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Simplified SCIP | 173e7f6c-72cb-4303-9809-a5a3f55f80bd Denmark |
| 1aca9ae7-a071-4d26-94ee-b797635caa40 Hungary | |
| 269eac4f-a499-4e92-9ac1-353df782a509 Norway | |
| 31a91a22-2916-4955-a991-5f590e643b3b Portugal | |
| 35d61cb5-0780-4a4d-af30-e5c72d326a76 Belgium | |
| 3babcdf2-37d9-4d76-9037-5548eebc50d8 Sweden | |
| 4cb43f76-afd6-408e-b130-969d62a0cfe5 Estonia | |
| 78253d29-d323-49e0-860c-c22a46644eb4 Croatia | |
| 8ca370a7-bc0a-4e72-bace-1bfd1306ed72 Germany | |
| 9099ec34-9ee8-438e-b477-734e2d8b4259 Czech Republic | |
| 96e44b7a-d1dd-4a40-b4f4-0d5bccc7f059 Germany | |
| 9ec1fcd2-de30-4c8a-a7ad-5007cc51d2c3 Poland | |
| a9179386-af0f-4aab-86fc-7c26417e97a5 Netherlands | |
| b26a55fb-18cf-438d-aa74-dd539021ed2a Finland | |
| b7d987df-8b23-4e83-846d-2abb581ad439 Italy | |
| ca260e0e-07da-48e7-adf4-9ee5d9cdd41a Spain | |
| d1d17068-f3d0-46d2-8aa5-f618ec790ac2 Greece | |
| f64aae63-eaf0-4fb6-b62d-93998f292fcd Poland | |
| fd0f55be-be4b-4788-bd22-3cd1c4d0c955 France | |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| Certificates and Declarations | |
| CCC Certificate | CCC_2018010304134049 |
| CQC Certificate | CQC2018010304134049 |
| Declaration of Conformity - CCC | 2020980304001624 |
| Declaration of Conformity - CE | 1SBD250803U1000 |
| Declaration of Conformity - UKCA | 1SBD250820U1000 |
| EAC Certificate | EAC_RU C-FR ME77 B01010 |
| GOST Certificate | GOST_POCCFRME77B07175 |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 142 mm |
| Package Level 1 Depth / Length | 190 mm |
| Package Level 1 Height | 136 mm |
| Package Level 1 Gross Weight | 1.42 kg |
| Package Level 1 EAN | 3471522245427 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE MOTOR PROTECTION EN.pdf | 240 Mbytes |
|
| AF45-40-00RT 20-60V DC Contactor - ABB - AF45-40-00RT - 1SBL337210R7200 | 87 Kbytes |
![]() |
| AF45-40-00RT 1SBL337210R7200 ABB AF45-40-00RT 20-60V DC Contactor | 87 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.