A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 24-60 V, 50 and 60 Hz, 20-60 V DC

Ordering

  • EAN:
    7320500480458
  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85364900

Dimensions

  • Product Net Width:
    105.0mm
  • Product Net Depth:
    152.0mm
  • Product Net Height:
    196.0mm
  • Product Net Weight:
    2.816kg

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    223 mm
  • Package Level 1 Length:
    133 mm
  • Package Level 1 Height:
    186 mm
  • Package Level 1 Gross Weight:
    3.266 kg
  • Package Level 1 EAN:
    7320500480458

Technical

  • Number of Main Contacts NO:
    3
  • Number of Main Contacts NC:
    0
  • Number of Auxiliary Contacts NO:
    2
  • Number of Auxiliary Contacts NC:
    2
  • Rated Operational Voltage:
    Main Circuit 1000 V
  • Rated Frequency (f):
    Main Circuit 50/60 Hz
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 °C 275 A
  • Rated Operational Current AC-1 (Ie):
    (690 V) 55 °C 250 A
    (690 V) 40 °C 275 A
    (1000 V) 40 °C 250 A
    (1000 V) 55 °C 225 A
    (690 V) 70 °C 200 A
    (1000 V) 70 °C 185 A
  • Rated Operational Current AC-3 (Ie):
    (1000 V) 55 °C 85 A
    (690 V) 55 °C 135 A
    (415 V) 55 °C 190 A
    (220 / 230 / 240 V) 55 °C 190 A
    (440 V) 55 °C 190 A
    (380 / 400 V) 55 °C 190 A
    (500 V) 55 °C 135 A
  • Rated Operational Power AC-3 (Pe):
    (500 V) 90 kW
    (1000 V) 110 kW
    (690 V) 132 kW
    (220 / 230 / 240 V) 55 kW
    (380 / 400 V) 90 kW
    (440 V) 110 kW
    (415 V) 90 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
    8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
    10 x Ie AC-3
  • Short-Circuit Protective Devices:
    gG Type Fuses 355 A
  • Rated Short-time Withstand Current (Icw):
    at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 275 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 878 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1520 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1900 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 621 A
  • Maximum Breaking Capacity:
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3300 A
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2200 A
  • Maximum Electrical Switching Frequency:
    AC-3 300 cycles per hour
    AC-1 300 cycles per hour
    AC-2 / AC-4 150 cycles per hour
  • Rated Operational Current DC-1 (Ie):
    (110 V) 2 Poles in Series, 40 °C 250 A
    (220 V) 3 Poles in Series, 40 °C 250 A
  • Rated Operational Current DC-3 (Ie):
    (110 V) 2 Poles in Series, 40 °C 250 A
    (220 V) 3 Poles in Series, 40 °C 250 A
  • Rated Operational Current DC-5 (Ie):
    (110 V) 2 Poles in Series, 40 °C 250 A
    (220 V) 3 Poles in Series, 40 °C 250 A
  • Rated Insulation Voltage (Ui):
    acc. to UL/CSA 600 V
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Rated Impulse Withstand Voltage (Uimp):
    Main Circuit 8 kV
  • Mechanical Durability:
    5 million
  • Maximum Mechanical Switching Frequency:
    300 cycles per hour
  • Coil Operating Limits:
    (acc. to IEC 60947-4-1)0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
  • Rated Control Circuit Voltage (Uc):
    60 Hz 24…60 V
    50 Hz 24…60 V
    DC Operation 20…60 V
  • Coil Consumption:
    Pull-in at Max. Rated Control Circuit Voltage 60 Hz 165 V·A
    Holding at Max. Rated Control Circuit Voltage DC 2.5 W
    Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A
    Pull-in at Max. Rated Control Circuit Voltage DC 205 W
    Pull-in at Max. Rated Control Circuit Voltage 50 Hz 165 V·A
    Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A
  • Operate Time:
    Between Coil Energization and NO Contact Closing 25…55 ms
    Between Coil De-energization and NO Contact Opening 37…47 ms
  • Connecting Capacity-Main Circuit:
    Rigid Al-Cable 1x95…185 mm²
    Flexible 1x6…120 mm²
    Rigid Cu-Cable 2x50…120 mm²
  • Connecting Capacity-Auxiliary Circuit:
    Solid 1x1…4 mm²
    Flexible with Insulated Ferrule 2x0.75…2.5 mm²
    Stranded 1x1…4 mm²
    Flexible 2x0.75…2.5 mm²
    Flexible with Ferrule 1x0.75…2.5 mm²
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
  • Terminal Type:
    Main Circuit: Bars

Environmental

  • Ambient Air Temperature:
    Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+50 °C
    Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °C
    Close to Contactor for Storage -40…+70 °C
  • Maximum Operating Altitude Permissible:
    3000 m
  • RoHS Status:
    Following EU Directive 2002/95/EC August 18, 2005 and amendment

Technical UL/CSA

  • Maximum Operating Voltage UL/CSA:
    Main Circuit 600 V
  • General Use Rating UL/CSA:
    (600 V AC) 250 A
  • Horsepower Rating UL/CSA:
    (208 V AC) Three Phase 50 Hp
    (440 ... 480 V AC) Three Phase 125 Hp
    (550 ... 600 V AC) Three Phase 150 Hp
    (220 ... 240 V AC) Three Phase 60 Hp
    (200 V AC) Three Phase 50 Hp

Certificates and Declarations (Document Number)

Classifications

  • ETIM 5:
    EC000066 - Magnet contactor, AC-switching
  • UNSPSC:
    39121529

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.