ANUNCIAR
1SFL447002R1111 ABB AF140-30-11B-11 Contactor View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SFL447002R1111 ABB AF140-30-11B-11 Contactor

1SFL447002R1111

ABB

AF140-30-11B-11 Contactor

AF140-30-11B-11 CONT. 3P B. 24-60VAC-DC

More details


Low-voltage industrial components > Power contactor, AC switching

Contactors and overload relays > AF contactors 100A to 370A

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $547.34
Unit price: $547.34
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
EPLAN Data9AAC174539_EPLAN
Data Sheet, Technical Information1SBC100214C0202
Data Sheet, Technical Information (Part 2)1SAC200017M0002
Instructions and Manuals1SFC100003M0201
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width90 mm
Product Net Depth / Length126 mm
Product Net Height150 mm
Product Net Weight1.3 kg
Dimension Diagram1SFB535001G1051
Technical
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Number of Poles3P
Rated Operational VoltageMain Circuit 690 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 200 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 200 A
(690 V) 70 °C 160 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 140 A
(440 V) 55 °C 140 A
(500 V) 55 °C 130 A
(690 V) 55 °C 80 A
(380 / 400 V) 55 °C 140 A
(220 / 230 / 240 V) 55 °C 140 A
Rated Operational Current AC-3e (Ie)(415 V) 60 °C 140 A
(440 V) 60 °C 140 A
(500 V) 60 °C 130 A
(690 V) 60 °C 80 A
(380 / 400 V) 60 °C 140 A
(220 / 230 / 240 V) 60 °C 140 A
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Power AC-3 (Pe)(415 V) 75 kW
(440 V) 90 kW
(500 V) 90 kW
(690 V) 75 kW
(380 / 400 V) 75 kW
(220 / 230 / 240 V) 37 kW
Rated Operational Power AC-3e (Pe)(415 V) 75 kW
(440 V) 90 kW
(500 V) 90 kW
(690 V) 75 kW
(380 / 400 V) 75 kW
(220 / 230 / 240 V) 37 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Breaking Capacity AC-3e8.5 x Ie AC-3e
Rated Making Capacity AC-310 x Ie AC-3
Rated Making Capacity AC-3e12 x Ie AC-3e
Short-Circuit Protective DevicesgG Type Fuses 315 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 674 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1460 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1168 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 477 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1500 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 5.5 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 5.5 V·A
Holding at Max. Rated Control Circuit Voltage DC 2.5 V·A
Holding at Max. Rated Control Circuit Voltage DC 2.5 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 225 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 225 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 210 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 210 W
Power Lossat Rated Operating Conditions per Pole 9 W
Operate TimeBetween Coil De-energization and NO Contact Opening 37 ... 47 ms
Between Coil Energization and NO Contact Closing 25 ... 55 ms
Connecting Capacity Main CircuitFlexible 1 x 10 ... 70 mm²
Flexible 2 x 10 ... 70 mm²
Rigid Cu-Cable 2 x 10 ... 95 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 1x0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 1 x 1 ... 4 mm²
Solid 2 x 1 ... 4 mm²
Stranded 1 x 1 .... 4 mm²
Stranded 2 x 1 .... 4 mm²
Connecting CapacityFlexible 1 x 10 ... 70 mm²
Flexible 2 x 10 ... 70 mm²
Rigid Cu-Cable 2 x 10 ... 95 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening TorqueCable Lug 9 N·m
Main Circuit 8 N·m
Terminal TypeMain Circuit: Bars
Product NameBlock Contactor
Technical UL/CSA
NEMA Size4
Continuous Current Rating NEMA135 A
Horsepower Rating NEMA(200 V AC) Three Phase 40 Hp
(230 V AC) Three Phase 50 Hp
(460 V AC) Three Phase 100 Hp
(575 V AC) Three Phase 100 Hp
Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 200 A
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 15 Hp
(200 V AC) Three Phase 40 hp
(208 V AC) Three Phase 40 hp
(220 ... 240 V AC) Three Phase 20 Hp
(220 ... 240 V AC) Three Phase 50 hp
(440 ... 480 V AC) Three Phase 40 Hp
(440 ... 480 V AC) Three Phase 100 hp
(550 ... 600 V AC) Three Phase 50 Hp
(550 ... 600 V AC) Three Phase 125 hp
Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 124 A
(550 ... 600 V AC) Three Phase 125 A
Environmental
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNon-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions1SFC100112M0001
Environmental Product Declaration - EPD1SFC100092D0201
2TFP200059A1001
Improved Energy Efficiency for CustomersProduct Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Sustainable Material Content in Product (wt. %)Recycled Metal - 37 %
Certificates and Declarations
A2L Certificate – UL9AKK108468A6693
ABS Certificate14-LD1092198-PDA
BV CertificateBV_36353_A0BV
CB CertificateSEMKO_SE-70479M1
CCS CertificateGB14T00030
CQC CertificateCQC2013010304604055
Declaration of Conformity - CCC2020980304001304
Declaration of Conformity - CE2CMT2015-005439
Declaration of Conformity - UKCA2CMT2020-006118
DNV CertificateDNV_E-14043
DNV GL CertificateDNV_E-14043
EAC Certificate9AKK107046A8618
GL CertificateDNV_E-14043
LR CertificateLR_14_70011(E1)
PRS CertificateTE_2092_880423_16
RINA CertificateELE060313XG_002
RMRS Certificate9AKK107045A6978
UL Certificate20120925-E36588
UL Listing CardUL_E36588
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width207 mm
Package Level 1 Depth / Length216 mm
Package Level 1 Height150 mm
Package Level 1 Gross Weight1.5 kg
Package Level 1 EAN7320500477137
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4758 >> Iec Contactors
E-Number (Finland)3706198
E-Number (Norway)4117625
E-Number (Sweden)3210107

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.