ANUNCIAR
2CCG001241R0001 ABB Int. aut. S802P-D80 2p 80A D 50kA View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

2CCG001241R0001 ABB Int. aut. S802P-D80 2p 80A D 50kA

2CCG001241R0001

ABB

Int. aut. S802P-D80 2p 80A D 50kA

S802P-D80 High Performance Circuit Breaker. D Characteristic. 50kA, 80A, 2P

More details


Circuit breakers and fuses > Miniature circuit breaker (MCB)

Industrial

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $304.11
Unit price: $304.11
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



ABB EcoSolutions
ABB EcoSolutionsYes
EcoSolutions Profile9AKK108471A1082
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 86.29 %
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
End Of Life Disassembling Instructions9AKK108470A2575
Environmental Product Declaration - EPD9AKK108470A1695
9AKK108470A1696
Technical
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(415 V AC) 50 kA
(440 V AC) 30 kA
(500 V AC) 15 kA
(690 V AC) 6 kA
(250 V DC) 30 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(240 / 415 V AC) 40 kA
Contact Position IndicationON / OFF / TRIP
Energy Limiting Class3
Number of Protected Poles2
Number of Poles2P
Tightening Torque3.5 N·m
Release TypeD
Actuator MarkingI / O
Recommended Screw DriverPozidriv 2
Accessories AvailableYes
Connecting CapacityFlexible 1...50 mm²
Rigid 1...70 mm²
Wire Stripping Length19 mm
Electrical
Tripping CharacteristicD
Rated Operational Voltageacc. to IEC 60898-1 400 V AC
acc. to IEC 60947-2 690 V AC
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 690 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Input Voltage TypeAC/DC
Rated Current (In)80 A
Rated Short-Circuit Capacity(400 V AC) 25 kA
Frequency (f)50/60 Hz
Rated Frequency (f)50/60 Hz
Power LossTotal 12.8 W
at Rated Operating Conditions per Pole 6.4 W
Overvoltage CategoryIII
Material Compliance
RoHS Declaration9AKK108468A0836
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Date20230505
REACH Declaration9AKK108470A9089
REACH InformationFalse - does not contain substances > 0.1 mass percentage
REACH Date20250313
Conflict Minerals Reporting Template (CMRT)9AKK108468A3363
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2BBusiness To Business
Environmental
Ambient Air TemperatureOperation -40 ... 70 °C
Storage -40 ... 70 °C
Reference Ambient Air Temperature30 °C
Degree of ProtectionIP20
Pollution Degree3
Dimensions
Width in Number of Modular Spacings3
Product Net Width54.0 mm
Product Net Height95.0 mm
Product Net Depth / Length82.5 mm
Product Net Weight490 g
Built-In Depth (t2)82.5 mm
Engineering
EPLAN Data9AAF605105_EPLAN
Ordering
Package Level 1 Unitsbox 1 piece
Package Level 1 Gross Weight525 g
E-Number (Finland)3217375
E-Number (Norway)1629224
E-Number (Sweden)2101449
Certificates and Declarations
CB Certificate9AKK108468A1243
CCC Certificate9AKK108468A8539
CEBEC Certificate9AKK108468A1244
Declaration of Conformity - CE9AKK108468A0836
Declaration of Conformity - UKCA9AKK108468A0837
DNV GL Certificate2CCC413018D0201
ESTI Certificate9AKK108468A2302
KC Certificate9AKK108468A8755
LR Certificate9AKK108468A8541
RINA Certificate9AKK108469A1379
UL Certificate9AKK108469A1794
VDE Certificate9AKK108468A6941
Installation
Instructions and Manuals2CCC413016M0008
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting PositionAny
Popular Downloads
Data Sheet, Technical Information9AKK108468A9560
9AKK108468A9561
9AKK108468A9562
External Classifications and Standards
ETIM 9EC000042 - Miniature circuit breaker (MCB)
ETIM 10EC000042 - Miniature circuit breaker (MCB)
UNSPSC39121603
eClassV11.0 : 27141901
IDEA Granular Category Code (IGCC)4899 >> Miniature circuit breaker (MCB) screw-in model
Object Classification CodeF
StandardsIEC/EN 60947-2
UL 1077

ETIM for 2CCG001241R0001 Circuit breakers and fuses (EC000042)
Feature Name Feature Value
Built-in depth (EF000218) 82.5 mm
Release characteristic (EF000889) D
Number of poles (total) (EF008618) 2
Number of protected poles (EF005548) 2
Rated current (EF000227) 80 A
Rated voltage (EF000228) 400 V
Rated insulation voltage Ui (EF001366) 690 V
Rated impulse withstand voltage Uimp (EF011980) 6 kV
Voltage type (EF000187) AC/DC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V (EF009555) 25 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V (EF009557) 30 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V (EF009558) 50 kA
Frequency (EF000416) 50 Hz
Current limiting class (EF002568) 3
Flush-mounted installation (EF007517) No
Concurrently switching neutral conductor (EF005997) No
Over voltage category (EF002569) 3
Pollution degree (EF002570) 3
Additional equipment possible (EF008148) Yes
Width in number of modular spacings (EF002950) 3
Degree of protection (IP) (EF005474) IP20
Ambient temperature during operating (EF007515) -25 °C
Connectable conductor cross section multi-wired (EF007343) 1 mm²
Connectable conductor cross section solid-core (EF007337) 1 mm²

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.