CM-UFD.M22M Grid feeding monitoring rel. 3c/o,L-L=0-540VAC,L-N=0-312VAC,ModbusRTU
Relays > Voltage monitoring relay
Electronic relays
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| EAN | 4013614521119 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC112258D0201 |
| Instructions and Manuals | 1SVC560510M0002 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 108 mm |
| Product Net Height | 90 mm |
| Product Net Depth / Length | 67 mm |
| Product Net Weight | 0.312 kg |
| Technical | |
| Function | Over- and undervoltage monitoring |
| Interrupted neutral monitoring | |
| Over- and underfrequency monitoring | |
| 10 minutes average value monitoring | |
| ROCOF monitoring | |
| Measuring Range | 0 ... 540 V AC |
| Rated Control Supply Voltage (Us) | 24 ... 240 V AC/DC |
| Output | 3 C/O (SPDT) Contacts |
| Terminal Type | Screw Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
| Minimum Switching Capacity | 24 V |
| 10 mA | |
| Degree of Protection | Housing IP20 |
| Terminals IP20 | |
| Pollution Degree | 3 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 10 A |
| Output Circuit NO - F Type Fuses 10 A | |
| Electrical Durability | AC-12 100000 cycle |
| Mechanical Durability | Nr. Operations 30000000 cycle |
| Connecting Capacity | Flexible with Ferrule 1x 0.25 ... 4.0 mm² |
| Flexible with Ferrule 2x 0.25 ... 0.75 mm² | |
| Flexible with Insulated Ferrule 1x 0.25 ... 4.0 mm² | |
| Flexible with Insulated Ferrule 2x 0.25 ... 0.75 mm² | |
| Flexible 1x 0.2 ... 4.0 mm² | |
| Flexible 2x 0.2 ... 1.5 mm² | |
| Rigid 1x 0.2 ... 6.0 mm² | |
| Rigid 2x 0.2 ... 1.5 mm² | |
| Tightening Torque | 0.5 ... 0.6 N·m |
| Wire Stripping Length | 8 mm |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
| TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | |
| Standards | IEC/EN 63000 |
| IEC/EN 60255-26 | |
| IEC/EN 60255-27 | |
| IEC/EN 61000-6-3 | |
| CEI 0-21 | |
| Technical UL/CSA | |
| Connecting Capacity UL/CSA | Flexible with Ferrule 1x 24-12 AWG |
| Flexible with Ferrule 2x 24-18 AWG | |
| Flexible with Insulated Ferrule 1x 24-12 AWG | |
| Flexible with Insulated Ferrule 2x 24-18 AWG | |
| Flexible 1x 24-12 AWG | |
| Flexible 2x 24-16 AWG | |
| Rigid 1x 24-10 AWG | |
| Rigid 2x 24-16 AWG | |
| Tightening Torque UL/CSA | 4.4 ... 5.3 in·lb |
| Environmental | |
| Ambient Air Temperature | Operation -20 ... +60 °C |
| Storage -25 ... +50 °C | |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD981001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006536 |
| ABB EcoSolutions | |
| Environmental Product Declaration - EPD | 1SAC200393H0001 |
| Certificates and Declarations | |
| Declaration of Conformity - CE | 1SVD981056-0001 |
| Declaration of Conformity - UKCA | 1SVD981056-1000 |
| TÜV Certificate | TUEV_AoC-44254-61719-02 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 121 mm |
| Package Level 1 Depth / Length | 71 mm |
| Package Level 1 Height | 99 mm |
| Package Level 1 Gross Weight | 0.365 kg |
| Package Level 1 EAN | 4013614521119 |
| External Classifications and Standards | |
| Object Classification Code | B |
| ETIM 7 | EC001438 - Voltage monitoring relay |
| ETIM 8 | EC001438 - Voltage monitoring relay |
| ETIM 9 | EC001438 - Voltage monitoring relay |
| eClass | V11.0 : 27371801 |
| E-Number (Finland) | 2712565 |
| Feature Name | Feature Value |
|---|---|
| Type of electric connection (EF003961) | Screw connection |
| Voltage measuring range 1 (EF006134) | 0 V |
| Voltage measuring range 2 (EF006135) | 0 V |
| Type of voltage measuring range (EF003399) | AC |
| Response value voltage (EF008193) | 0 V |
| Min. adjustable delay-on energization time (EF008190) | 1 s |
| Min. adjustable off-delay time (EF008192) | 1 s |
| Width (EF000008) | 108 mm |
| Height (EF000040) | 90 mm |
| Depth (EF000049) | 67 mm |
| Title: | Size: | Type: |
|---|---|---|
| PDF ABB Time Relays CT-C CT-S CT-D 2024 EN.pdf | 47 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.