Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| EPLAN Data | 9AAC412764_EPLAN |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Data Sheet, Technical Information (Part 2) | 1SAC200017M0002 |
| Instructions and Manuals | 1SFC380023-en |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 186 mm |
| Product Net Depth / Length | 216 mm |
| Product Net Height | 278 mm |
| Product Net Weight | 10.6 kg |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 2 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 600 A |
| Rated Operational Current AC-1 (Ie) | (1000 V) 40 °C 600 A |
| (1000 V) 55 °C 500 A | |
| (1000 V) 70 °C 400 A | |
| (690 V) 40 °C 600 A | |
| (690 V) 55 °C 500 A | |
| (690 V) 70 °C 400 A | |
| Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 400 A |
| (440 V) 55 °C 400 A | |
| (500 V) 55 °C 400 A | |
| (690 V) 55 °C 350 A | |
| (1000 V) 55 °C 155 A | |
| (380 / 400 V) 55 °C 400 A | |
| (220 / 230 / 240 V) 55 °C 400 A | |
| Rated Operational Current DC-1 (Ie) | (110 V) 1-Pole, 40 °C 600 A |
| (110 V) 2 Poles in Series, 40 °C 600 A | |
| (220 V) 3 Poles in Series, 40 °C 600 A | |
| (600 V) 3 Poles in Series, 40 °C 600 A | |
| Rated Operational Current DC-3 (Ie) | (110 V) 1-Pole, 40 °C 600 A |
| (110 V) 2 Poles in Series, 40 °C 600 A | |
| (220 V) 3 Poles in Series, 40 °C 600 A | |
| (600 V) 3 Poles in Series, 40 °C 600 A | |
| Rated Operational Current DC-5 (Ie) | (110 V) 1-Pole, 40 °C 600 A |
| (110 V) 2 Poles in Series, 40 °C 600 A | |
| (220 V) 3 Poles in Series, 40 °C 600 A | |
| (600 V) 3 Poles in Series, 40 °C 600 A | |
| Rated Operational Power AC-3 (Pe) | (415 V) 220 kW |
| (440 V) 220 kW | |
| (500 V) 250 kW | |
| (690 V) 315 kW | |
| (1000 V) 220 kW | |
| (380 / 400 V) 200 kW | |
| (220 / 230 / 240 V) 110 kW | |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Short-Circuit Protective Devices | gG Type Fuses 630 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 840 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 3100 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 4600 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 4400 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 2500 A | |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 4000 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3500 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 1000 V | |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| (AC-2 / AC-4) 60 cycles per hour | |
| (AC-3) 300 cycles per hour | |
| Mechanical Durability | 3 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc) | 50 Hz 24 ... 60 V |
| DC Operation 24 ... 60 V | |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | |
| Holding at Max. Rated Control Circuit Voltage DC 7.5 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 50 Hz 900 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 60 Hz 900 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage DC 900 V·A | |
| Power Loss | at Rated Operating Conditions per Pole 16 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 45 ... 55 ms |
| Between Coil De-energization and NO Contact Opening 48 ... 58 ms | |
| Between Coil Energization and NC Contact Opening 45 ... 115 ms | |
| Between Coil Energization and NO Contact Closing 50 ... 120 ms | |
| Connecting Capacity Main Circuit | Bar 47 mm² |
| Rigid Al-Cable 240 mm² | |
| Rigid Al-Cable 2x240 mm² | |
| Rigid Cu-Cable 240 mm² | |
| Rigid Cu-Cable 2x240 mm² | |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1x 0.75 ... 2.5 mm² |
| Flexible with Ferrule 2x 0.75 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | |
| Flexible 1x0.75 ... 2.5 mm² | |
| Flexible 2x0.75 ... 2.5 mm² | |
| Solid 2 x 1 ... 4 mm² | |
| Stranded 2 x 1 .... 4 mm² | |
| Connecting Capacity | Bar 47 mm² |
| Rigid Al-Cable 2x240 mm² | |
| Rigid Cu-Cable 2x240 mm² | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 | |
| Connecting Terminals (delivered in open position) Main Poles | M 3.5 (+,-) pozidriv 2 screw with cable clamp |
| Recommended Screw Driver | Main Circuit M10 |
| Control Circuit 5.5 | |
| Control Circuit M3.5 | |
| Control Circuit Pozidriv 2 | |
| Tightening Torque | Cable Lug 35 N·m |
| Main Circuit 35 N·m | |
| Terminal Type | Main Circuit: Bars |
| Suitable for Product Class | Block ContactorsBlock Contactors |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 1000 V |
| General Use Rating UL/CSA | (1000 V AC) 550 A |
| (600 V AC) 550 A | |
| Horsepower Rating UL/CSA | (200 ... 208 V AC) Three Phase 125 Hp |
| (200 ... 208 V AC) Three Phase 125 hp | |
| (200 V AC) Three Phase 125 hp | |
| (208 V AC) Three Phase 125 hp | |
| (220 ... 240 V AC) Three Phase 150 Hp | |
| (220 ... 240 V AC) Three Phase 150 hp | |
| (440 ... 480 V AC) Three Phase 350 Hp | |
| (440 ... 480 V AC) Three Phase 350 hp | |
| (550 ... 600 V AC) Three Phase 400 Hp | |
| (550 ... 600 V AC) Three Phase 400 hp | |
| Full Load Amps Motor Use | (200 ... 208 V AC) Three Phase 358.8 A |
| (220 ... 240 V AC) Three Phase 360 A | |
| (440 ... 480 V AC) Three Phase 414 A | |
| (550 ... 600 V AC) Three Phase 382 A | |
| Environmental | |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C |
| Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | |
| Close to Contactor for Storage -40 ... 70 °C | |
| Operation -40 ... 70 °C | |
| Storage -40 ... +70 °C | |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | Shock Direction: A 5 g |
| Shock Direction: B1 5 g | |
| Shock Direction: B2 5 g | |
| Shock Direction: C1 5 g | |
| Shock Direction: C2 5 g | |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility |
| Environmental Product Declaration - EPD | 1SFC100105D0201 |
| Improved Energy Efficiency for Customers | Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 63.1 % |
| Sustainable Material Content in Product (wt. %) | Recycled Metal - 37 % |
| Certificates and Declarations | |
| CB Certificate | SE-82316 |
| CQC Certificate | CQC2007010304256683 |
| Declaration of Conformity - CCC | 2020980304001300 |
| Declaration of Conformity - CE | 2CMT2018-005695 |
| Declaration of Conformity - UKCA | 2CMT2020-006125 |
| EAC Certificate | 1SFC101360D1101 |
| SUVA Certificate | 2CMT2019-005859 |
| UL Certificate | 20121207-E36588 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 280 mm |
| Package Level 1 Depth / Length | 375 mm |
| Package Level 1 Height | 310 mm |
| Package Level 1 Gross Weight | 12 kg |
| Package Level 1 EAN | 7320500540930 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4758 >> Iec Contactors |
| E-Number (Finland) | 3709036 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE MOTOR PROTECTION EN.pdf | 240 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.