1SFL527062R1222 ABB AF205B-30-22RT-12 Contactor View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SFL527062R1222 ABB AF205B-30-22RT-12 Contactor

1SFL527062R1222

ABB

AF205B-30-22RT-12 Contactor

More details


Contactors and overload relays

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information1SBC100214C0202
Data Sheet, Technical Information (Part 2)1SAC200017M0002
Instructions and Manuals1SFC100008M0201
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width105 mm
Product Net Depth / Length152 mm
Product Net Height196 mm
Product Net Weight2.4 kg
Technical
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
Number of Poles3P
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 275 A
(1000 V) 60 °C 250 A
(1000 V) 70 °C 200 A
(690 V) 40 °C 350 A
(690 V) 60 °C 300 A
(690 V) 70 °C 240 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 205 A
(440 V) 55 °C 205 A
(500 V) 55 °C 165 A
(690 V) 55 °C 165 A
(1000 V) 55 °C 100 A
(380 / 400 V) 55 °C 205 A
(220 / 230 / 240 V) 55 °C 205 A
Rated Operational Current DC-1 (Ie)(100 V) 1 Pole, 40 °C 350 A
(100 V) 1 Pole, 60 °C 300 A
(100 V) 1 Pole, 70 °C 240 A
(110 V) 2 Poles in Series, 40 °C 350 A
(110 V) 2 Poles in Series, 60 °C 300 A
(110 V) 2 Poles in Series, 70 °C 240 A
(110 V) 3 Poles in Series, 40 °C 350 A
(110 V) 3 Poles in Series, 60 °C 300 A
(110 V) 3 Poles in Series, 70 °C 240 A
(175 V) 2 Poles in Series, 40 °C 350 A
(175 V) 2 Poles in Series, 60 °C 300 A
(175 V) 2 Poles in Series, 70 °C 240 A
(200 V) 2 Poles in Series, 40 °C 350 A
(200 V) 2 Poles in Series, 60 °C 300 A
(200 V) 2 Poles in Series, 70 °C 240 A
(220 V) 3 Poles in Series, 40 °C 350 A
(220 V) 3 Poles in Series, 60 °C 300 A
(220 V) 3 Poles in Series, 70 °C 240 A
(260 V) 3 Poles in Series, 40 °C 350 A
(260 V) 3 Poles in Series, 60 °C 300 A
(260 V) 3 Poles in Series, 70 °C 240 A
(300 V) 3 Poles in Series, 40 °C 350 A
(300 V) 3 Poles in Series, 60 °C 300 A
(300 V) 3 Poles in Series, 70 °C 240 A
(72 V) 1-Pole, 40 °C 350 A
(72 V) 1-Pole, 60 °C 300 A
(72 V) 1-Pole, 70 °C 240 A
(72 V) 2 Poles in Series, 40 °C 350 A
(72 V) 2 Poles in Series, 60 °C 300 A
(72 V) 2 Poles in Series, 70 °C 240 A
(72 V) 3 Poles in Series, 40 °C 350 A
(72 V) 3 Poles in Series, 60 °C 300 A
(72 V) 3 Poles in Series, 70 °C 240 A
(90 V) 1 Pole, 40 °C 350 A
(90 V) 1 Pole, 60 °C 300 A
(90 V) 1 Pole, 70 °C 240 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 275 A
(110 V) 2 Poles in Series, 60 °C 275 A
(110 V) 2 Poles in Series, 70 °C 240 A
(110 V) 3 Poles in Series, 40 °C 275 A
(110 V) 3 Poles in Series, 60 °C 275 A
(110 V) 3 Poles in Series, 70 °C 240 A
(220 V) 3 Poles in Series, 40 °C 275 A
(220 V) 3 Poles in Series, 60 °C 275 A
(220 V) 3 Poles in Series, 70 °C 240 A
(72 V) 2 Poles in Series, 40 °C 275 A
(72 V) 2 Poles in Series, 60 °C 275 A
(72 V) 2 Poles in Series, 70 °C 240 A
(72 V) 3 Poles in Series, 40 °C 275 A
(72 V) 3 Poles in Series, 60 °C 275 A
(72 V) 3 Poles in Series, 70 °C 240 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 275 A
(110 V) 2 Poles in Series, 60 °C 275 A
(110 V) 2 Poles in Series, 70 °C 240 A
(110 V) 3 Poles in Series, 40 °C 275 A
(110 V) 3 Poles in Series, 60 °C 275 A
(110 V) 3 Poles in Series, 70 °C 240 A
(220 V) 3 Poles in Series, 40 °C 275 A
(220 V) 3 Poles in Series, 60 °C 275 A
(220 V) 3 Poles in Series, 70 °C 240 A
(72 V) 2 Poles in Series, 40 °C 275 A
(72 V) 2 Poles in Series, 60 °C 275 A
(72 V) 2 Poles in Series, 70 °C 240 A
(72 V) 3 Poles in Series, 40 °C 275 A
(72 V) 3 Poles in Series, 60 °C 275 A
(72 V) 3 Poles in Series, 70 °C 240 A
Rated Operational Power AC-3 (Pe)(415 V) 110 kW
(440 V) 132 kW
(500 V) 110 kW
(690 V) 160 kW
(1000 V) 132 kW
(380 / 400 V) 110 kW
(220 / 230 / 240 V) 55 kW
Rated Breaking Capacity AC-3e8.5 x Ie AC-3e
Rated Making Capacity AC-310 x Ie AC-3
Rated Making Capacity AC-3e12 x Ie AC-3e
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 947 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 2050 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1640 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 670 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
(AC-3) 300 cycles per hour
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz / 60 Hz 48 ... 130 V
DC Operation 48 ... 130 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 14.5 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 14.5 V·A
Holding at Max. Rated Control Circuit Voltage DC 2.5 V·A
Holding at Max. Rated Control Circuit Voltage DC 2.5 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 340 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 340 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 465 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 465 W
Power Loss8 W
at Rated Operating Conditions per Pole 8 W
Connecting Capacity Main CircuitFlexible 2 x 50 ... 95 mm²
Rigid Cu-Cable 2 x 50 ... 120 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Connecting CapacityFlexible 2 x 50 ... 95 mm²
Rigid Cu-Cable 2 x 50 ... 120 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening TorqueCable Lug 9 N·m
Main Circuit 14 ... 31 N·m
Terminal TypeMain Circuit: Bars
Product NameBlock Contactor
Technical UL/CSA
Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(1000 V AC) 275 A
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 60 hp
(220 ... 240 V AC) Three Phase 75 hp
(440 ... 480 V AC) Three Phase 150 hp
(550 ... 600 V AC) Three Phase 200 hp
Full Load Amps Motor Use(200 ... 208 V AC) Three Phase 177 A
(220 ... 240 V AC) Three Phase 192 A
(440 ... 480 V AC) Three Phase 180 A
(550 ... 600 V AC) Three Phase 192 A
Environmental
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
End Of Life Disassembling Instructions1SFC100112M0001
Environmental Product Declaration - EPD1SFC100095D0201
Certificates and Declarations
A2L Certificate – UL9AKK108468A6695
CB CertificateSE-82315
CQC CertificateCQC2014010304676685
Declaration of Conformity - CCC2020980304001306
Declaration of Conformity - CE2CMT2015-005440
Declaration of Conformity - UKCA2CMT2020-006124
EAC Certificate9AKK107046A8618
UR Certificate20150602-E36588_1
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width160 mm
Package Level 1 Depth / Length258 mm
Package Level 1 Height235 mm
Package Level 1 Gross Weight3 kg
Package Level 1 EAN7320500510230
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.