Product successfully added to your shopping cart
1SFL487102R1100
ABB
1
AF190-40-00-11 Contactor
Contactors and overload relays
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| EPLAN Data | 9AAC174541_EPLAN |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Data Sheet, Technical Information (Part 2) | 1SAC200017M0002 |
| Instructions and Manuals | 1SFC100008M0201 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 140 mm |
| Product Net Depth / Length | 153 mm |
| Product Net Height | 196 mm |
| Product Net Weight | 3.3 kg |
| Dimension Diagram | 1SFB535001G1122 |
| Technical | |
| Number of Main Contacts NO | 4 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 4P |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Main Circuit 60 Hz |
| Main Circuit 50 / 60 Hz | |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 275 A |
| Rated Operational Current AC-1 (Ie) | (1000 V) 40 °C 250 A |
| (1000 V) 55 °C 225 A | |
| (1000 V) 60 °C 225 A | |
| (1000 V) 70 °C 185 A | |
| (690 V) 40 °C 275 A | |
| (690 V) 55 °C 250 A | |
| (690 V) 60 °C 250 A | |
| (690 V) 70 °C 200 A | |
| Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 190 A |
| (440 V) 55 °C 190 A | |
| (380 / 400 V) 55 °C 190 A | |
| (220 / 230 / 240 V) 55 °C 190 A | |
| Rated Operational Power AC-3 (Pe) | (415 V) 90 kW |
| (440 V) 110 kW | |
| (380 / 400 V) 90 kW | |
| (220 / 230 / 240 V) 55 kW | |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Breaking Capacity AC-3e | 8.5 x Ie AC-3e |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Rated Making Capacity AC-3e | 12 x Ie AC-3e |
| Short-Circuit Protective Devices | gG Type Fuses 355 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 275 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 878 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1900 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1520 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 621 A | |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3300 A |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| (AC-3) 300 cycles per hour | |
| Mechanical Durability | 5 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc) | 50 Hz 24 ... 60 V |
| 60 Hz 24 ... 60 V | |
| DC Operation 20 ... 60 V | |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 10 V·A | |
| Holding at Max. Rated Control Circuit Voltage DC 2.5 V·A | |
| Holding at Max. Rated Control Circuit Voltage DC 2.5 W | |
| Pull-in at Max. Rated Control Circuit Voltage 50 Hz 245 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 60 Hz 245 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage DC 370 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage DC 370 W | |
| Power Loss | 15 W |
| at Rated Operating Conditions per Pole 15 W | |
| Operate Time | Between Coil De-energization and NO Contact Opening 45 ... 80 ms |
| Between Coil Energization and NO Contact Closing 25 ... 60 ms | |
| Connecting Capacity Main Circuit | Flexible 2 x 50 ... 95 mm² |
| Rigid Al-Cable 1 x 95 ... 185 mm² | |
| Rigid Cu-Cable 2 x 50 ... 120 mm² | |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm² |
| Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | |
| Flexible 1x0.75 ... 2.5 mm² | |
| Flexible 2x0.75 ... 2.5 mm² | |
| Solid 2 x 1 ... 4 mm² | |
| Stranded 2 x 1 .... 4 mm² | |
| Connecting Capacity | Flexible 2 x 50 ... 95 mm² |
| Rigid Cu-Cable 2 x 10 ... 95 mm² | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 | |
| Tightening Torque | Cable Lug 9 N·m |
| Main Circuit 14 ... 31 N·m | |
| Terminal Type | Main Circuit: Bars |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (1000 V AC) 250 A |
| Horsepower Rating UL/CSA | (200 ... 208 V AC) Three Phase 20 Hp |
| (200 V AC) Three Phase 50 hp | |
| (208 V AC) Three Phase 50 hp | |
| (220 ... 240 V AC) Three Phase 25 Hp | |
| (220 ... 240 V AC) Three Phase 60 hp | |
| (440 ... 480 V AC) Three Phase 60 Hp | |
| (440 ... 480 V AC) Three Phase 125 hp | |
| (550 ... 600 V AC) Three Phase 75 Hp | |
| (550 ... 600 V AC) Three Phase 150 hp | |
| Environmental | |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C |
| Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | |
| Close to Contactor for Storage -40 ... 70 °C | |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility |
| End Of Life Disassembling Instructions | 1SFC100112M0001 |
| Environmental Product Declaration - EPD | 1SFC100095D0201 |
| Improved Energy Efficiency for Customers | Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.2 % |
| Sustainable Material Content in Product (wt. %) | Recycled Metal - 35 % |
| Certificates and Declarations | |
| ABS Certificate | 14-LD1092198-PDA |
| 14-LD1092198-1-PDA-DUP | |
| BV Certificate | BV_36353_A0BV |
| CB Certificate | SE-82315 |
| CQC Certificate | CQC2014010304676685 |
| Declaration of Conformity - CCC | 2020980304001306 |
| Declaration of Conformity - CE | 2CMT2015-005440 |
| Declaration of Conformity - UKCA | 2CMT2020-006118 |
| EAC Certificate | 9AKK107046A8618 |
| LR Certificate | 16-20064 |
| PRS Certificate | TE_2092_880423_16 |
| RINA Certificate | ELE060313XG_002 |
| RMRS Certificate | 9AKK107045A6978 |
| UL Certificate | 20140925-E73397 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 166 mm |
| Package Level 1 Depth / Length | 238 mm |
| Package Level 1 Height | 180 mm |
| Package Level 1 Gross Weight | 3.9 kg |
| Package Level 1 EAN | 7320500504208 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4758 >> Iec Contactors |
| E-Number (Finland) | 3707179 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE MOTOR PROTECTION EN.pdf | 240 Mbytes |
|
| 1SFL487102R1100 EN_1SFL487102R1100.pdf | 127 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.