1SFL447263R1322 ABB AF140B-40-22-13 Contactor View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SFL447263R1322 ABB AF140B-40-22-13 Contactor

1SFL447263R1322

ABB

AF140B-40-22-13 Contactor

More details


Contactors and overload relays

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information1SBC100214C0202
Data Sheet, Technical Information (Part 2)1SAC200017M0002
Instructions and Manuals1SFC100003M0201
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width120 mm
Product Net Depth / Length128 mm
Product Net Height150 mm
Product Net Weight2.05 kg
Technical
Number of Main Contacts NO4
Number of Main Contacts NC0
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
Number of Poles4P
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 200 A
(690 V) 60 °C 175 A
(690 V) 70 °C 160 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 140 A
(440 V) 55 °C 140 A
(380 / 400 V) 55 °C 140 A
(220 / 230 / 240 V) 55 °C 140 A
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 40 °C 200 A
(110 V) 2 Poles in Series, 60 °C 175 A
(110 V) 2 Poles in Series, 70 °C 160 A
(110 V) 3 Poles in Series, 40 °C 200 A
(110 V) 3 Poles in Series, 60 °C 175 A
(110 V) 3 Poles in Series, 70 °C 160 A
(175 V) 2 Poles in Series, 40 °C 200 A
(175 V) 2 Poles in Series, 60 °C 175 A
(175 V) 2 Poles in Series, 70 °C 160 A
(220 V) 3 Poles in Series, 40 °C 200 A
(220 V) 3 Poles in Series, 60 °C 175 A
(220 V) 3 Poles in Series, 70 °C 160 A
(260 V) 3 Poles in Series, 40 °C 200 A
(260 V) 3 Poles in Series, 60 °C 175 A
(260 V) 3 Poles in Series, 70 °C 160 A
(350 V) 4 Poles in Series, 40 °C 200 A
(350 V) 4 Poles in Series, 60 °C 175 A
(350 V) 4 Poles in Series, 70 °C 160 A
(72 V) 1-Pole, 40 °C 200 A
(72 V) 1-Pole, 60 °C 175 A
(72 V) 1-Pole, 70 °C 160 A
(72 V) 2 Poles in Series, 40 °C 200 A
(72 V) 2 Poles in Series, 60 °C 175 A
(72 V) 2 Poles in Series, 70 °C 160 A
(72 V) 3 Poles in Series, 40 °C 200 A
(72 V) 3 Poles in Series, 60 °C 175 A
(72 V) 3 Poles in Series, 70 °C 160 A
(90 V) 1 Pole, 40 °C 200 A
(90 V) 1 Pole, 60 °C 175 A
(90 V) 1 Pole, 70 °C 160 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 160 A
(110 V) 2 Poles in Series, 60 °C 160 A
(110 V) 2 Poles in Series, 70 °C 160 A
(110 V) 3 Poles in Series, 40 °C 160 A
(110 V) 3 Poles in Series, 60 °C 160 A
(110 V) 3 Poles in Series, 70 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 60 °C 160 A
(220 V) 3 Poles in Series, 70 °C 160 A
(72 V) 2 Poles in Series, 40 °C 160 A
(72 V) 2 Poles in Series, 60 °C 160 A
(72 V) 2 Poles in Series, 70 °C 160 A
(72 V) 3 Poles in Series, 40 °C 160 A
(72 V) 3 Poles in Series, 60 °C 160 A
(72 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 160 A
(110 V) 2 Poles in Series, 60 °C 160 A
(110 V) 2 Poles in Series, 70 °C 160 A
(110 V) 3 Poles in Series, 40 °C 160 A
(110 V) 3 Poles in Series, 60 °C 160 A
(110 V) 3 Poles in Series, 70 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 60 °C 160 A
(220 V) 3 Poles in Series, 70 °C 160 A
(72 V) 2 Poles in Series, 40 °C 160 A
(72 V) 2 Poles in Series, 60 °C 160 A
(72 V) 2 Poles in Series, 70 °C 160 A
(72 V) 3 Poles in Series, 40 °C 160 A
(72 V) 3 Poles in Series, 60 °C 160 A
(72 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Power AC-3 (Pe)(415 V) 75 kW
(440 V) 90 kW
(500 V) 90 kW
(690 V) 75 kW
(380 / 400 V) 75 kW
(220 / 230 / 240 V) 37 kW
Rated Breaking Capacity AC-3e8.5 x Ie AC-3e
Rated Making Capacity AC-310 x Ie AC-3
Rated Making Capacity AC-3e12 x Ie AC-3e
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 674 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1460 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1168 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 477 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
(AC-3) 300 cycles per hour
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz / 60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 30.7 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 30.7 V·A
Holding at Max. Rated Control Circuit Voltage DC 2.8 V·A
Holding at Max. Rated Control Circuit Voltage DC 2.8 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 220 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 220 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 275 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 275 W
Power Loss18 W
at Rated Operating Conditions per Pole 18 W
Connecting Capacity Main CircuitFlexible 2 x 10 ... 70 mm²
Rigid Cu-Cable 2 x 10 ... 95 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Connecting CapacityFlexible 2 x 10 ... 70 mm²
Rigid Cu-Cable 2 x 10 ... 95 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening TorqueCable Lug 9 N·m
Terminal TypeMain Circuit: Bars
Product NameBlock Contactor
Technical UL/CSA
NEMA Size4
Continuous Current Rating NEMA135 A
Horsepower Rating NEMA(200 V AC) Three Phase 40 Hp
(230 V AC) Three Phase 50 Hp
(460 V AC) Three Phase 100 Hp
(575 V AC) Three Phase 100 Hp
Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 175 A
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 15 Hp
(200 V AC) Three Phase 40 hp
(208 V AC) Three Phase 40 hp
(220 ... 240 V AC) Three Phase 20 Hp
(220 ... 240 V AC) Three Phase 50 hp
(440 ... 480 V AC) Three Phase 40 Hp
(440 ... 480 V AC) Three Phase 100 hp
(550 ... 600 V AC) Three Phase 50 Hp
(550 ... 600 V AC) Three Phase 125 hp
Environmental
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNon-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions1SFC100112M0001
Environmental Product Declaration - EPD1SFC100092D0201
Improved Energy Efficiency for CustomersProduct Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Sustainable Material Content in Product (wt. %)Recycled Metal - 37 %
Certificates and Declarations
CB CertificateSEMKO_SE-77317
CQC CertificateCQC2013010304604055
Declaration of Conformity - CCC2020980304001304
Declaration of Conformity - CE2CMT2015-005440
Declaration of Conformity - UKCA2CMT2020-006124
EAC Certificate9AKK107046A8618
KC Certificate9AKK107046A9911
UL CertificateE73397_20140710
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width147 mm
Package Level 1 Depth / Length197 mm
Package Level 1 Height155 mm
Package Level 1 Gross Weight2.25 kg
Package Level 1 EAN7320500511367
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors
E-Number (Sweden)3210466

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE MOTOR PROTECTION EN.pdf 240 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.