1SFL437063R7211
ABB
1
AF95B-30-11 20-60V DC Contactor
Contactors and overload relays
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SBC100192C0206 |
| Instructions and Manuals | 5309660-60 |
| Dimensions | |
| Product Net Width | 102 mm |
| Product Net Depth / Length | 123.5 mm |
| Product Net Height | 148 mm |
| Product Net Weight | 1.9 kg |
| Dimension Diagram | 53540923-1 |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives. |
| Rated Operational Voltage | Main Circuit 1000 V |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 145 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 145 A |
| (690 V) 55 °C 135 A | |
| (690 V) 70 °C 115 A | |
| Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 96 A |
| (440 V) 55 °C 93 A | |
| (500 V) 55 °C 80 A | |
| (690 V) 55 °C 65 A | |
| (1000 V) 55 °C 30 A | |
| (380 / 400 V) 55 °C 96 A | |
| (220 / 230 / 240 V) 55 °C 96 | |
| Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 40 °C 145 A |
| (110 V) 2 Poles in Series, 55 °C 135 A | |
| (110 V) 2 Poles in Series, 70 °C 115 A | |
| (110 V) 3 Poles in Series, 40 °C 145 A | |
| (110 V) 3 Poles in Series, 55 °C 135 A | |
| (110 V) 3 Poles in Series, 70 °C 115 A | |
| (220 V) 3 Poles in Series, 40 °C 145 A | |
| (220 V) 3 Poles in Series, 55 °C 135 A | |
| (220 V) 3 Poles in Series, 70 °C 115 A | |
| Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 40 °C 145 A |
| (110 V) 2 Poles in Series, 55 °C 135 A | |
| (110 V) 2 Poles in Series, 70 °C 115 A | |
| (110 V) 3 Poles in Series, 40 °C 145 A | |
| (110 V) 3 Poles in Series, 55 °C 135 A | |
| (110 V) 3 Poles in Series, 70 °C 115 A | |
| (220 V) 3 Poles in Series, 40 °C 145 A | |
| (220 V) 3 Poles in Series, 55 °C 135 A | |
| (220 V) 3 Poles in Series, 70 °C 115 A | |
| (72 V) 1-Pole, 40 °C 130 A | |
| (72 V) 1-Pole, 55 °C 130 A | |
| (72 V) 1-Pole, 70 °C 115 A | |
| Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 40 °C 145 A |
| (110 V) 2 Poles in Series, 55 °C 135 A | |
| (110 V) 2 Poles in Series, 70 °C 115 A | |
| (110 V) 3 Poles in Series, 40 °C 145 A | |
| (110 V) 3 Poles in Series, 55 °C 135 A | |
| (110 V) 3 Poles in Series, 70 °C 115 A | |
| (220 V) 3 Poles in Series, 40 °C 145 A | |
| (220 V) 3 Poles in Series, 55 °C 135 A | |
| (220 V) 3 Poles in Series, 70 °C 115 A | |
| Rated Operational Power AC-3 (Pe) | (415 V) 55 kW |
| (440 V) 55 kW | |
| (500 V) 55 kW | |
| (690 V) 55 kW | |
| (1000 V) 40 kW | |
| (380 / 400 V) 45 kW | |
| (220 / 230 / 240 V) 25 kW | |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Short-Circuit Protective Devices | gG Type Fuses 160 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| (AC-2 / AC-4) 150 cycles per hour | |
| (AC-3) 300 cycles per hour | |
| Mechanical Durability | 10 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc) | DC Operation 20 ... 60 V |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A | |
| Holding at Max. Rated Control Circuit Voltage DC 2 W | |
| Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 60 Hz 350 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage DC 400 W | |
| Power Loss | at Rated Operating Conditions per Pole 3.5 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 60 ... 130 ms |
| Between Coil De-energization and NO Contact Opening 55 ... 125 ms | |
| Between Coil Energization and NC Contact Opening 27 ... 77 ms | |
| Between Coil Energization and NO Contact Closing 30 ... 80 ms | |
| Connecting Capacity Main Circuit | Bar 30 mm² |
| Flexible with Cable End 2 x 6 ... 35 mm² | |
| Rigid 2 x 6 ... 65 mm² | |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1x 0.75 ... 2.5 mm² |
| Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
| Flexible 2x0.75 ... 2.5 mm² | |
| Solid 2 x 1 ... 4 mm² | |
| Stranded 2 x 1 .... 4 mm² | |
| Connecting Capacity | Bar 30 mm² |
| Flexible with Cable End 2 x 6 ... 35 mm² | |
| Rigid 2 x 6 ... 65 mm² | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 | |
| Connecting Terminals (delivered in open position) Main Poles | M8 hexagon socket screw with single connector |
| Tightening Torque | Main Circuit 8 N·m |
| Terminal Type | Cable Clamp |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 125 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 7-1/2 hp |
| (200 ... 208 V AC) Three Phase 30 hp | |
| (200 V AC) Three Phase 30 hp | |
| (208 V AC) Three Phase 30 hp | |
| (220 ... 240 V AC) Three Phase 30 hp | |
| (240 V AC) Single Phase 20 hp | |
| (440 ... 480 V AC) Three Phase 60 hp | |
| (550 ... 600 V AC) Three Phase 75 hp | |
| Full Load Amps Motor Use | (120 V AC) Single Phase 80 A |
| (200 ... 208 V AC) Three Phase 92 A | |
| (220 ... 240 V AC) Three Phase 80 A | |
| (240 V AC) Single Phase 88 A | |
| (440 ... 480 V AC) Three Phase 77 A | |
| (550 ... 600 V AC) Three Phase 77 A | |
| Environmental | |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C |
| Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | |
| Close to Contactor for Storage -60 ... +80 °C | |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 g | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g | |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Certificates and Declarations | |
| BV Certificate | 13409/C0 BV |
| CB Certificate | SE-73661 |
| CQC Certificate | CQC2002010304007860 |
| Declaration of Conformity - CCC | 2020980304001857 |
| Declaration of Conformity - CE | 2CMT2015-005436 |
| Declaration of Conformity - UKCA | 2CMT2020-006118 |
| EAC Certificate | 9AKK107046A8618 |
| GL Certificate | GL_20260-04HH |
| LR Certificate | LR_04-00015-E1 |
| RINA Certificate | ELE060313XG/002 |
| RMRS Certificate | RMRS_12-03683-315 |
| TÜV Certificate | MHM-EST-7.70017788e |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 130 mm |
| Package Level 1 Depth / Length | 265 mm |
| Package Level 1 Height | 162 mm |
| Package Level 1 Gross Weight | 2.1 kg |
| Package Level 1 EAN | 7320500318072 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE MOTOR PROTECTION EN.pdf | 240 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.