Product successfully added to your shopping cart
1SFL427001R3300
ABB
1
AF116-30-00-33 Contactor
Low-voltage industrial components > Power contactor, AC switching
Contactors and overload relays
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| EPLAN Data | 9AAC174538_EPLAN |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Data Sheet, Technical Information (Part 2) | 1SAC200017M0002 |
| Instructions and Manuals | 1SFC100003M0201 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 90 mm |
| Product Net Depth / Length | 142.5 mm |
| Product Net Height | 150 mm |
| Product Net Weight | 1.55 kg |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main Circuit 690 V |
| Rated Frequency (f) | Main Circuit 60 Hz |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 160 A |
| (690 V) 60 °C 145 A | |
| (690 V) 70 °C 130 A | |
| Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 116 A |
| (440 V) 55 °C 116 A | |
| (500 V) 55 °C 110 A | |
| (690 V) 55 °C 65 A | |
| (380 / 400 V) 55 °C 116 A | |
| (220 / 230 / 240 V) 55 °C 116 A | |
| Rated Operational Current AC-3e (Ie) | (415 V) 60 °C 116 A |
| (440 V) 60 °C 116 A | |
| (500 V) 60 °C 110 A | |
| (690 V) 60 °C 65 A | |
| (380 / 400 V) 60 °C 116 A | |
| (220 / 230 / 240 V) 60 °C 116 A | |
| Rated Operational Power AC-3 (Pe) | (415 V) 55 kW |
| (440 V) 75 kW | |
| (500 V) 75 kW | |
| (690 V) 55 kW | |
| (380 / 400 V) 55 kW | |
| (220 / 230 / 240 V) 30 kW | |
| Rated Operational Power AC-3e (Pe) | (415 V) 55 kW |
| (440 V) 75 kW | |
| (500 V) 75 kW | |
| (690 V) 55 kW | |
| (380 / 400 V) 55 kW | |
| (220 / 230 / 240 V) 30 kW | |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Breaking Capacity AC-3e | 8.5 x Ie AC-3e |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Rated Making Capacity AC-3e | 12 x Ie AC-3e |
| Short-Circuit Protective Devices | gG Type Fuses 250 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1160 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| (AC-2 / AC-4) 150 cycles per hour | |
| (AC-3) 300 cycles per hour | |
| Mechanical Durability | 5 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc) | 50 Hz 100 ... 250 V |
| 60 Hz 100 ... 250 V | |
| DC Operation 100 ... 250 V | |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 30.7 V·A |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 30.7 V·A | |
| Holding at Max. Rated Control Circuit Voltage DC 2.8 V·A | |
| Holding at Max. Rated Control Circuit Voltage DC 2.8 W | |
| Pull-in at Max. Rated Control Circuit Voltage 50 Hz 220 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 60 Hz 220 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage DC 275 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage DC 275 W | |
| Power Loss | at Rated Operating Conditions per Pole 6 W |
| Operate Time | Between Coil De-energization and NO Contact Opening 37 ... 47 ms |
| Between Coil Energization and NO Contact Closing 25 ... 55 ms | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40 |
| Terminal Type | Double Clamp |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| General Use Rating UL/CSA | (600 V AC) 160 A |
| Horsepower Rating UL/CSA | (200 ... 208 V AC) Three Phase 15 Hp |
| (200 V AC) Three Phase 30 hp | |
| (208 V AC) Three Phase 30 hp | |
| (220 ... 240 V AC) Three Phase 20 Hp | |
| (220 ... 240 V AC) Three Phase 40 hp | |
| (440 ... 480 V AC) Three Phase 40 Hp | |
| (440 ... 480 V AC) Three Phase 75 hp | |
| (550 ... 600 V AC) Three Phase 50 Hp | |
| (550 ... 600 V AC) Three Phase 100 hp | |
| Environmental | |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C |
| Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | |
| Close to Contactor for Storage -40 ... 70 °C | |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility |
| End Of Life Disassembling Instructions | 1SFC100112M0001 |
| Environmental Product Declaration - EPD | 1SFC100092D0201 |
| Improved Energy Efficiency for Customers | Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 87.8 % |
| Sustainable Material Content in Product (wt. %) | Recycled Metal - 37 % |
| Certificates and Declarations | |
| A2L Certificate – UL | 9AKK108468A6693 |
| ABS Certificate | 14-LD1092198-PDA |
| BV Certificate | BV_36353_A0BV |
| CB Certificate | SEMKO_SE-70479M1 |
| CCS Certificate | GB14T00030 |
| CQC Certificate | CQC2013010304604055 |
| Declaration of Conformity - CCC | 2020980304001304 |
| Declaration of Conformity - CE | 2CMT2015-005439 |
| Declaration of Conformity - UKCA | 2CMT2020-006118 |
| DNV Certificate | DNV_E-14043 |
| EAC Certificate | 9AKK107046A8618 |
| LR Certificate | 16-20064 |
| PRS Certificate | TE_2092_880423_16 |
| RINA Certificate | ELE060313XG_002 |
| RMRS Certificate | 9AKK107045A6978 |
| UL Certificate | 20120925-E36588 |
| UL Listing Card | UL_E36588 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 207 mm |
| Package Level 1 Depth / Length | 216 mm |
| Package Level 1 Height | 150 mm |
| Package Level 1 Gross Weight | 1.75 kg |
| Package Level 1 EAN | 7320500478493 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4758 >> Iec Contactors |
| E-Number (Finland) | 3707479 |
| Feature Name | Feature Value |
|---|---|
| Rated control supply voltage AC 50 Hz (EF003978) | 100 V |
| Rated control supply voltage AC 60 Hz (EF003979) | 100 V |
| Rated control supply voltage DC (EF003980) | 100 V |
| Voltage type for actuating (EF008242) | AC/DC |
| Rated operation current Ie at AC-1, 400 V (EF001393) | 160 A |
| Rated operation current Ie at AC-3, 400 V (EF001392) | 116 A |
| Rated operation power at AC-3, 400 V (EF001364) | 55 kW |
| Rated operation power NEMA (EF011960) | 14.9140 kW |
| Modular version (EF001126) | No |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Type of electrical connection of main circuit (EF006819) | Screw connection |
| Number of normally closed contacts as main contact (EF001375) | 0 |
| Number of normally open contacts as main contact (EF001374) | 3 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE MOTOR PROTECTION EN.pdf | 240 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.