Product successfully added to your shopping cart
1SDA107590R1
ABB
1
XT6H 800 Ekip Dip LSIG In=630 3p F F
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2356 |
| Environmental Product Declaration - EPD | 9AKK108468A9752 |
| 9AKK108468A2295 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 60 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 20f5a449-f0aa-4078-a376-35c02a0a10c7 China |
| Simplified SCIP | fdf5527a-964d-4206-983c-60d548fa9d2b France |
| bfafe079-4d1c-4c92-93bf-503d2f5b0bee Netherlands | |
| a4adf547-e895-4c5f-aee0-014ea6500fb0 Poland | |
| 4015a591-b177-4a3a-badb-fde1cf2b057a Czech Republic | |
| 80aeb7ce-bee2-494b-9bd7-1c2e0e1e0bdb Croatia | |
| aa4d5d4a-14f8-421a-a360-4c6819ffb45f Norway | |
| 53e68b33-4ecd-4b1c-9a88-97d562ac9998 Germany | |
| db14d8d8-f019-4cc1-9ad4-ce4123576b86 Spain | |
| 09524bce-f45d-4fbf-a9d3-9217f53ac605 Poland | |
| 58f5958b-fca0-4012-8dd8-1c46918229ad Hungary | |
| e6f08fa7-0965-4fbb-98c7-72b8fb5d7c06 Sweden | |
| 718738b7-a9bf-47d3-9f24-823bdc69f064 Belgium | |
| 74e37561-b46f-4d14-ba9a-dbbbdbd4ca57 Bulgaria | |
| 6118a2bd-9f75-475d-9646-567bc9d341a2 France | |
| 2ed0050e-6cf5-4f6d-bd7e-8cbaa031b45e Belgium | |
| bdaffc0f-9b7c-435c-9b28-5e888fccb0c2 Finland | |
| 22cd8f48-31a3-4266-b1e3-dfcae11c1ef7 Germany | |
| 6c272430-5d96-4699-823f-f339a58c821b Germany | |
| ab68f4dd-499e-470f-8705-ab5ab69a6f82 Portugal | |
| 4b94dc9a-7d7e-477d-aaf6-9b166754bfa4 Germany | |
| 9fff9615-be35-4729-8be4-6d6960f672d9 Greece | |
| a29402aa-6fb9-4322-9752-366ca8fd28c1 Denmark | |
| b0baf99a-d0c3-4892-8d93-b12fc0ee0e9a Estonia | |
| 50990f02-ac49-4a93-af58-12025899f9d1 Hungary | |
| 9345b57d-fa3f-43c0-a6f9-119ec1d3b8a3 Poland | |
| 65232412-413e-4a3d-8dbc-56a15671d00e Germany | |
| 2abf603f-15c1-48cc-abdf-2fd07e1af1ed Sweden | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT6HE3630GFF000XXX |
| EAN | 8015644102432 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 9.5 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 305 mm |
| Package Level 1 Height | 285 mm |
| Package Level 1 Depth / Length | 370 mm |
| Package Level 1 Gross Weight | 11 kg |
| Package Level 1 EAN | 8015644102432 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Suitable for Product Class | SACE Tmax XT |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1190 |
| 1SDH002065A1245 | |
| Technical | |
| Configuration Type | Loose or configurable |
| Current Type | AC |
| Electrical Durability | 5000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | 33.2 W |
| Rated Current (In) | 630 A |
| Rated Frequency (f) | 50/60 Hz |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 25 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 10 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 25 kA | |
| (250 V DC) 2 Poles in Series 70 kA | |
| (500 V DC) 2 Poles in Series 50 kA | |
| (750 V DC) 3 Poles in Series 36 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Release | Ekip Dip LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC60947-2 |
| Sub-type | XT6 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2825 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002012A1101 |
| Wiring Diagram | 1SDM000005A1001 |
| Instructions and Manuals | 1SDH002012A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 630 A |
| Rated voltage (EF003977) | 690 V |
| Overload release current setting (EF002336) | 252.0 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 630 A |
| Adjustment range undelayed short-circuit release (EF007131) | 630 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With switched-off indicator (EF007006) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Front |
| Type of control element (EF006976) | Toggle |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG ABB TMAX XT EN.pdf | 70 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.