ANUNCIAR

1SDA107585R1 ABB XT6S 800 Ekip Dip LSIG In 630 4p F F

1SDA107585R1

ABB

XT6S 800 Ekip Dip LSIG In=630 4p F F

More details


Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection

Molded case "Isomax-Tmax"

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $4,404.27
Unit price: $4,404.27
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions9AKK108468A2356
Environmental Product Declaration - EPD9AKK108468A9752
9AKK108468A2295
Extended Product LifetimeProduct Modularity
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 60 %
Material Compliance
REACH Declaration9AKK108466A1425
RoHS Declaration9AKK108466A1424
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
Toxic Substances Control Act - TSCA9AKK108467A8326
SCIP00b31b17-4e8d-459e-b46b-5ed5eaab522d Italy
Simplified SCIP3cd37734-6abd-4e55-951c-3d3a84950aad Germany
6d3fa783-165c-444d-9676-49ba397790e0 France
f78189b8-a32a-411f-aa06-43e5ad608c5c Netherlands
7839ad6f-50f0-4413-8ab0-2f118000b32a Finland
f3ce0442-fdf7-4f24-9310-bff92aa4e5a3 Poland
ff3727f2-a655-40ee-8938-f20d9041f827 Denmark
b88f0936-54b8-46f0-bb32-b6165657c0fb Germany
9ab57c61-4c10-40cb-b322-1da0aa059c4c Germany
b6629151-9206-4f5a-ba51-4608da4deb20 Belgium
b06b083a-9c77-4fd4-8143-4f74fe4187a0 Poland
9bdd9cf5-85a0-4d4c-9e7e-a89d859ae97d Czech Republic
e7d07270-b8a4-4b5e-aff3-6703b7ae79b6 Croatia
d6b213c0-3ea6-4bbd-ace5-bda8e49b6ae8 Germany
3303aa05-7d91-40e0-9696-57bbaf30e6a3 Norway
7bd380c3-b1f6-4877-ac37-733a55b46e19 Germany
3fd21888-1e4e-498d-9f9f-9949c009b9e4 Sweden
8c8e2fc8-5cc7-4fee-a5eb-0cf332692e8a France
a071ac72-8109-463f-b5ef-b58a40e9c925 Poland
e0541e6c-e5ef-4b2d-b39e-436b8505eb7b Sweden
e0e6d6f2-3e60-445a-9f3d-81d3be3a82b0 Portugal
d94422f3-5e9e-4ab6-a411-ffd47387c333 Bulgaria
705af680-386e-466f-bc36-6ac78f3868c5 Estonia
6013c251-ab52-41a3-8a8a-c55b07edc2b3 Greece
59878862-bd56-474c-b2d8-8d05273f2bb0 Hungary
4ad7b8de-f72c-480a-b72b-6538fb482419 Spain
60bf9927-6f42-407b-af51-5a2f8a94afb2 Belgium
76173318-55f2-417a-b559-760b40b75d51 Hungary
Environmental
Environmental Information9AKK108467A6707
Ordering
Order Code US and CanadaXT6SE4630GFF000XXX
EAN8015644102388
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Dimensions
Product Net Width280 mm
Product Net Height268 mm
Product Net Depth / Length103.5 mm
Product Net Weight12 kg
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width305 mm
Package Level 1 Height285 mm
Package Level 1 Depth / Length370 mm
Package Level 1 Gross Weight14 kg
Package Level 1 EAN8015644102388
Additional Information
Circuit Breaker Type to be AssociatedPower Distribution
Product Main TypeSACE Tmax XT
Product NameMoulded Case Circuit Breaker
Product TypeAutomatic Circuit Breaker
Suitable for Product ClassSACE Tmax XT
VersionF
CAD Dimensional Drawing1SDH002065A1214
1SDH002065A1245
Technical
Configuration TypeLoose or configurable
Current TypeAC
Electrical Durability5000 cycle
60 cycles per hour
Mechanical Durability20000 cycle
120 cycles per hour
Number of Poles4P
Order Multiple1 piece
Power Loss33.2 W
Rated Current (In)630 A
Rated Frequency (f)50/60 Hz
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Insulation Voltage (Ui)1000 V
Rated Operational Voltage690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 45 kA
(500 V AC) 35 kA
(525 V AC) 35 kA
(690 V AC) 22 kA
Rated Short-time Withstand Current Low Voltage (Icw)10 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 45 kA
(500 V AC) 35 kA
(525 V AC) 35 kA
(690 V AC) 22 kA
(250 V DC) 2 Poles in Series 50 kA
(500 V DC) 2 Poles in Series 35 kA
(750 V DC) 3 Poles in Series 24 kA
Rated Uninterrupted Current (Iu)800 A
ReleaseEkip Dip LSIG
Release TypeEL
Short-Circuit Performance LevelS
StandardsIEC60947-2
Sub-typeXT6
Terminal Connection TypeFront
Certificates and Declarations
Data Sheet, Technical Information1SDC210100D0206
1SDC210099D0206
Declaration of Conformity - CE9AKK107680A2825
EU Data Act Compliance Declaration1SDH002560A1001
Mechanical Drawings1SDH002012A1101
Wiring Diagram1SDM000005A1001
Instructions and Manuals1SDH002012A1001
External Classifications and Standards
ETIM 9EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10EC000228 - Power circuit-breaker for trafo/generator/installation protection
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
eClassV11.1 : 27370409

ETIM for 1SDA107585R1 Low-voltage industrial controls and switchgear (EC000228)
Feature Name Feature Value
Rated permanent current Iu (EF001389) 630 A
Rated voltage (EF003977) 690 V
Overload release current setting (EF002336) 252.0 A
Adjustment range short-term delayed short-circuit release (EF007129) 630 A
Adjustment range undelayed short-circuit release (EF007131) 630 A
Integrated earth fault protection (EF007296) No
Type of electrical connection of main circuit (EF006819) Bolt connection
Device construction (EF008240) Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting (EF007250) No
DIN rail (top hat rail) mounting optional (EF008904) No
Number of auxiliary contacts as normally closed contact (EF001377) 0
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as change-over contact (EF003531) 0
With switched-off indicator (EF007006) No
With integrated under voltage release (EF001390) No
Number of poles (EF001391) 4
Position of connection for main current circuit (EF006671) Front
Type of control element (EF006976) Toggle
Complete device with protection unit (EF008906) Yes
Motor drive integrated (EF006697) No
Motor drive optional (EF007386) Yes
Degree of protection (IP) (EF005474) IP20

Datasheet - PDF

Title: Size: Type:
PDF CATALOG ABB TMAX XT EN.pdf 70 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.