Product successfully added to your shopping cart
1SDA100978R1
ABB
1
XT7L 800 Ekip Touch Meas.LSIG In800 3pFF
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2357 |
| Environmental Product Declaration - EPD | 9AKK108468A1895 |
| 9AKK108468A4404 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 64.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 8b882950-8f75-4325-8fdc-2a21382da887 Italy |
| Simplified SCIP | 9630da52-226e-498b-8cc8-2e1d8c32c6d4 Sweden |
| f2590b73-6eec-461a-917b-988f00daf057 Poland | |
| 4a10a5c2-5108-41d1-871d-f0d9b9649be0 Netherlands | |
| 882580b9-6e38-46eb-9599-5a1a318a7f7f Belgium | |
| c595cd02-b631-4bf3-b222-4d9fc5ad257a Spain | |
| a76d2907-f306-4336-bc6d-04a803be6327 Germany | |
| b497bc10-d368-43d5-8d12-a83d017edcbb France | |
| 943c5175-6421-4a21-9963-10f5a88294e4 Portugal | |
| f5970d03-2362-462d-9898-bd15035245c4 France | |
| d675d286-9faf-41f9-aafb-48cb48958dbb Sweden | |
| 79151c48-ff7a-4b55-84ac-ee48fcf2e217 Hungary | |
| 433995cf-8926-4a71-a750-497eeb2935a1 Bulgaria | |
| 7e0464d0-ec03-4afe-a9ad-2a4964427eaa Germany | |
| d23409f6-eabd-4f8c-97a6-411f874144a5 Belgium | |
| 90ce16ce-0f4e-443a-8127-24b60977a326 Finland | |
| 5d053ec3-0f5d-4d07-9670-9ff6eaf8dd39 Germany | |
| 0d9c5e32-0766-478e-bdf5-8f48b1395d6e Poland | |
| 9402ac48-8c5d-4176-beaf-e8e3378adfdc Poland | |
| c570b470-1300-4026-82e1-4dda321771bd Germany | |
| 08a05e73-c7b8-40a3-bf11-132c6cedfeeb Germany | |
| 2c694b28-ee8f-4f26-8c87-622de09d014a Czech Republic | |
| e3ea6c33-f23d-4266-b163-5f673649e71d Denmark | |
| 576e9ac1-faf7-4828-9623-515aa75fad12 Norway | |
| cd9b2573-641b-454e-b40f-0061f52c9352 Greece | |
| 5a68f7e5-a602-4f3b-ae7c-ad4e01bbd0e8 Estonia | |
| 14d1c96a-acaf-49d0-ac04-626479b5b18e Hungary | |
| a809a38e-52d0-4d30-a797-41a61db04b3e Croatia | |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... 125 °C |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT7LE380CSFF000XXX |
| EAN | 8056221010320 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 166 mm |
| Product Net Weight | 9.7 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 280 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 360 mm |
| Package Level 1 Gross Weight | 11.2 kg |
| Package Level 1 EAN | 8056221010320 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1336 |
| 1SDH002065A1338 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 3000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 10000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 24 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 200 kA |
| (230 V AC) 200 kA | |
| (240 V AC) 200 kA | |
| (380 V AC) 120 kA | |
| (415 V AC) 120 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (525 V AC) 65 kA | |
| (690 V AC) 50 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 20 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 200 kA |
| (230 V AC) 200 kA | |
| (240 V AC) 200 kA | |
| (380 V AC) 120 kA | |
| (415 V AC) 120 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (525 V AC) 65 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Release | Ekip Touch Measuring LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | L |
| Standards | IEC60947-2 |
| Sub-type | XT7 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107046A9648 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002013A1101 |
| Wiring Diagram | 1SDM000002A1001 |
| Instructions and Manuals | 1SDH002013A1001 |
| 1SDH002013A1002 | |
| 1SDH001821A1001 | |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 800 A |
| Rated voltage (EF003977) | 690 V |
| Overload release current setting (EF002336) | 320.0 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 480.0 A |
| Adjustment range undelayed short-circuit release (EF007131) | 1200.0 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With switched-off indicator (EF007006) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Front |
| Type of control element (EF006976) | Toggle |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG ABB TMAX XT EN.pdf | 70 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.