Product successfully added to your shopping cart
1SDA100854R1
ABB
1
XT7S 800 Ekip Hi-Touch LSI In800A 3p FF
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2357 |
| Environmental Product Declaration - EPD | 9AKK108468A1895 |
| 9AKK108468A4404 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 64.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 99c5bbbd-7b42-471b-b8d5-8d8ff0990bea Italy |
| Simplified SCIP | 7799f124-88d5-4b51-9e7e-791644f388bd Belgium |
| 6fa78d3f-7af3-43d3-a1ce-205ae8b750c8 Spain | |
| 3075b25a-bb40-4e07-8112-66f1f50a6c6a Bulgaria | |
| a500c658-ffa1-4be3-b4d3-aa1d6bcb7d2b Hungary | |
| 301bf068-7e3a-463c-a79d-2b567284c5d0 Germany | |
| d765c02a-506b-4113-8c15-f9063ef11ca4 France | |
| 04a33783-d96f-4a40-a2d4-87dcb66b13ca Sweden | |
| 0f804629-e358-49af-a4bc-f755926540de Portugal | |
| 20f7f32c-1245-4522-a3e8-3f32dfa66a4c France | |
| 11b22048-7ff9-4c88-b512-c502ff2bcebf Germany | |
| 161ee83b-af30-4c7b-98e0-ef69bd06a79c Finland | |
| 4de3cc6c-2266-41b5-bc47-2c534cde1c94 Germany | |
| 253e8e55-41be-4bc3-9a63-415eb1b06fd8 Poland | |
| ad57fc94-7dbe-4283-9f5b-b3cab3c7c737 Poland | |
| b24d0dfe-8461-4996-b7da-8e797805318b Netherlands | |
| d212a9b8-8a84-4b44-93db-9994078eb6d4 Croatia | |
| acdc52ce-7359-42de-aa45-5b2b37fb5267 Sweden | |
| 5b8f4004-2573-453a-a007-513726bb084b Estonia | |
| 613d678c-a639-4d03-9e6f-5f8a5693c009 Hungary | |
| 8d381519-3eb0-4355-828f-77bfaf0e6aff Greece | |
| 8e39772b-5735-4967-8794-f4cdf46a9215 Belgium | |
| 9c5aef9c-3633-4c1b-9c00-98f119adf5f6 Germany | |
| d4571b2f-687a-4a2c-afbe-c5ac94393ad8 Czech Republic | |
| 09819d03-6982-4bc0-b7f9-96c8843e6d74 Germany | |
| 69c39857-5353-4cd1-9590-daefb0e5fce6 Denmark | |
| de09bcb5-10ec-4ba3-9679-35f5fa6599d2 Norway | |
| ba7848ac-2261-42d8-aa31-d45a97c3743e Poland | |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... 125 °C |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT7SE380CTFF000XXX |
| E-Number (Norway) | 4380639 |
| EAN | 8056221009089 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 166 mm |
| Product Net Weight | 9.7 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 280 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 360 mm |
| Package Level 1 Gross Weight | 11.2 kg |
| Package Level 1 EAN | 8056221009089 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1336 |
| 1SDH002065A1338 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 3000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 10000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 24 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 45 kA | |
| (525 V AC) 45 kA | |
| (690 V AC) 30 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 20 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 45 kA | |
| (525 V AC) 45 kA | |
| (690 V AC) 30 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Release | Ekip Hi-Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT7 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107046A9648 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002013A1101 |
| Wiring Diagram | 1SDM000002A1001 |
| Instructions and Manuals | 1SDH002013A1001 |
| 1SDH002013A1002 | |
| 1SDH001821A1001 | |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 800 A |
| Rated voltage (EF003977) | 690 V |
| Overload release current setting (EF002336) | 320.0 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 480.0 A |
| Adjustment range undelayed short-circuit release (EF007131) | 1200.0 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With switched-off indicator (EF007006) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Front |
| Type of control element (EF006976) | Toggle |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG ABB TMAX XT EN.pdf | 70 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.