Product successfully added to your shopping cart
1SDA100429R1
ABB
1
XT5S 630 Ekip Dip LSI In=630 3p F F
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2354 |
| Environmental Product Declaration - EPD | 9AKK108468A1899 |
| 9AKK108468A9748 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 59.6 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 062558ae-c06a-470e-9252-cecb295edd79 Italy |
| Simplified SCIP | 616a2059-24d0-4848-b463-71086126614f Estonia |
| e344d9d6-2383-42e6-986a-25433646b3b9 Norway | |
| cbf5bc33-84b4-4f49-9718-077bd2457ac6 Spain | |
| 2feb5390-25ca-4637-a37f-0f079c8ab932 Belgium | |
| f5d74bd1-aafa-416b-94db-9fc0e4771ad1 Portugal | |
| cb793008-0242-4a63-a61d-d7195ef46d60 Bulgaria | |
| e30ad8d6-ea2a-4341-b428-dd1a39c6ecb6 Hungary | |
| 802cfd0a-b97d-48b8-b5da-f0f3b6c4cbb9 Greece | |
| e65d5792-a7fe-4ae5-bd1d-1948cadda84d France | |
| 32fa778a-c60b-49bf-abae-b79f6e0198c7 Germany | |
| bd5c7783-9e4a-4fa4-9b31-a76724634c07 Hungary | |
| f621b60c-635b-4644-931b-2ee943483ae2 Netherlands | |
| c8762103-d3a1-493b-826d-d4bb62da2758 Poland | |
| cb32ffa5-b654-4e7b-83ad-eda911dadbcf Czech Republic | |
| 8136a732-fbad-4470-a42a-495ced270590 Denmark | |
| ab5ce9c2-7aec-453c-a083-51ceb81b1bb7 Germany | |
| 9c37fc7f-bbf5-401e-8546-1d0a8be8cab6 Croatia | |
| 78ecfb52-94af-4cd6-ab66-8d95e0253872 Finland | |
| cff574ff-b5c9-4572-944c-bd12bc77a0c4 Belgium | |
| 92bc8ab7-2afb-467d-a5ab-a93e5ec3edf5 Germany | |
| 6918d23c-2104-478c-bd45-24a10ad5fe16 Germany | |
| 4e708dd1-72fa-4a5d-b788-d3e2ea72d977 Poland | |
| 84e5e7f6-87d0-4e9c-8065-b1eadd9abbd9 Germany | |
| a5baf458-87eb-46c3-ba6f-5843f1d73a9a France | |
| 52dc3def-2f68-4347-8383-598e7db45be9 Sweden | |
| 40f8914f-5379-4c75-b92a-3dea07bec5f0 Sweden | |
| 05646145-7b7f-49af-9568-81d93d98b51f Poland | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT5SE363BFFF000XXX |
| E-Number (Finland) | 3641348 |
| E-Number (Norway) | 4380280 |
| EAN | 8056221005067 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 140 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 4.82 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 250 mm |
| Package Level 1 Height | 245 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 5.308 kg |
| Package Level 1 EAN | 8056221005067 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1115 |
| 1SDH002065A1131 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 5000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | 45 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 25 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 6 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 25 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT5 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2824 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002011A1101 |
| Wiring Diagram | 1SDM000005A1001 |
| Instructions and Manuals | 1SDH002011A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 630 A |
| Rated voltage (EF003977) | 690 V |
| Overload release current setting (EF002336) | 252.0 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 630 A |
| Adjustment range undelayed short-circuit release (EF007131) | 630 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With switched-off indicator (EF007006) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Front |
| Type of control element (EF006976) | Toggle |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG ABB TMAX XT EN.pdf | 70 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.