Product successfully added to your shopping cart
1SDA100423R1
ABB
1
XT5S 400 Ekip Dip LS/I In=320 3p F F
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2354 |
| Environmental Product Declaration - EPD | 9AKK108468A1899 |
| 9AKK108468A9748 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 59.6 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 8f119ca7-a5ff-46da-bf84-6b295969e936 China |
| Simplified SCIP | 85f6e75b-21a6-41d6-a76c-97c13e917e44 Sweden |
| ca821937-b36c-4ed8-ba9a-b226604cc77c Portugal | |
| 7a5067ea-984d-4ccf-9b76-dead3b329c3c France | |
| e6b2b416-f30a-4949-ab01-f5a6a6aff645 Poland | |
| 49bfe90d-2b99-4b02-9b39-681c4dc68bc9 Bulgaria | |
| da44af03-e80f-492c-82a1-f2129484b774 Germany | |
| d84d6d48-bdfb-49d4-959a-1e1550e325b9 Netherlands | |
| 206134c8-3e82-4a0c-8549-09f5d7c03276 Greece | |
| 90ce6eb7-d800-40f3-86fa-c89cd17d2720 Hungary | |
| fb1ab54c-bb5a-44de-9635-d402528b36e6 Germany | |
| e44a7079-db0f-4c19-9771-5bc32d34dfa9 Estonia | |
| 31c696a3-0132-455b-9baf-8ede4cfe7d7d Sweden | |
| d79113c4-6159-4870-98c0-92f323120159 Poland | |
| 5aed8fd5-711c-4ebc-8846-d2d3a89e9711 Norway | |
| 09bc2bf1-1ebc-4ab1-8011-e03f67d764e0 Czech Republic | |
| 91a66905-a81f-4501-9779-cc081d4ca261 Croatia | |
| 3d40dbfb-8218-4fc8-ad15-bb6a99b6a461 Finland | |
| 73774ba1-7ba0-4721-88b7-eaab41c601de Poland | |
| 0cc1fe32-c0a5-4944-9650-2c4a16648cf0 Belgium | |
| 9fb7f5a7-8938-4718-9408-12a537d95aa6 Hungary | |
| e1482e4f-f190-4e01-9d36-aa0a71c1bd7f France | |
| 208100cb-300a-4cfc-adf2-b26763b8df71 Germany | |
| f8975927-c258-47e3-8060-978c69561646 Germany | |
| 4d73fd7e-631f-486f-9dd5-a34edf0ff24b Spain | |
| 09437f50-f833-4aed-a8d6-2c2e082449ed Germany | |
| dafade81-ed8f-456a-aeb1-d72751d28d12 Denmark | |
| ed2e1e5d-f909-4d1d-86e0-3b1a48d3cae3 Belgium | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT5SE332AEFF000XXX |
| E-Number (Finland) | 3641336 |
| E-Number (Norway) | 4380274 |
| EAN | 8056221005005 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 140 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 4.82 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 250 mm |
| Package Level 1 Height | 245 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 5.308 kg |
| Package Level 1 EAN | 8056221005005 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1115 |
| 1SDH002065A1131 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 7000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | 11.6 W |
| Rated Current (In) | 320 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 25 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 5 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 30 kA | |
| (690 V AC) 25 kA | |
| Rated Uninterrupted Current (Iu) | 400 A |
| Release | Ekip Dip LS/I |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT5 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107680A2824 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002011A1101 |
| Wiring Diagram | 1SDM000005A1001 |
| Instructions and Manuals | 1SDH002011A1001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 320 A |
| Rated voltage (EF003977) | 690 V |
| Overload release current setting (EF002336) | 128.0 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 320 A |
| Adjustment range undelayed short-circuit release (EF007131) | 320 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With switched-off indicator (EF007006) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Front |
| Type of control element (EF006976) | Toggle |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG ABB TMAX XT EN.pdf | 70 Mbytes |
|
| 1SDA100423R1 1SDA100423R1 EN_1SDA100423R1.pdf | 408 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.