Product successfully added to your shopping cart
1SDA056493R1
ABB
1
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Service Breakers
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | c9ee621c-635c-4d7b-ad18-48cb8b0bae7e Italy |
| Simplified SCIP | be249dce-a651-4364-85a1-4bf4038b773b Sweden |
| ab12d8c9-3cdd-45e4-bac1-3b83d2fa67c5 France | |
| 73c7d71d-bb1f-47d7-823d-304b07fd2c07 Sweden | |
| b5386682-862e-4f01-91af-6637d04bd779 Finland | |
| 81ecfcff-a032-4c30-9d32-d43f84f82f20 Norway | |
| 71873d8e-0f66-4400-89fc-572dfcce4931 Belgium | |
| 0e70ef50-0c0f-4057-935f-6323d183f5d3 Germany | |
| 452abbd8-9adc-4d8d-acf5-bf3d1e6e6c96 Poland | |
| 98c1cb29-d4c1-491f-aaad-24a884d1c019 Germany | |
| 3e409903-e4d6-4b20-9aae-f13bb2f2469c Spain | |
| 2312667d-0e1d-49f0-87a8-a605f77b8710 France | |
| 842e9d62-8b44-4246-ab4f-34b1afe7a5d1 Hungary | |
| 07cd3ec2-5e01-4b53-b042-26aa3deb65e1 Belgium | |
| 77b1c43e-415f-4989-b11e-3453f746642b Netherlands | |
| f12e56b7-878c-465e-a4b3-47ff56f2e456 Poland | |
| c5c03d6b-8e9a-4055-9623-f009cba46c04 Czech Republic | |
| 5c8f70bd-1a25-451e-b71b-18d12f9d7660 Greece | |
| c287e72b-f4f1-4ed9-a19d-2da69f684688 Estonia | |
| f95289ee-4919-4fe2-9fce-ca2959bcd289 Portugal | |
| 799820bf-7b98-46c7-883e-fa4bb9b6fabf Poland | |
| c247310c-0801-44ca-af50-35842437be63 Bulgaria | |
| d6768270-6a56-41ce-9bc9-86390ec176ca Denmark | |
| b2a86edf-ed4a-49d1-a582-213db3914840 Croatia | |
| 5c9c0f53-4427-4a92-a0f4-5e70ce7d9a38 Germany | |
| e4410c15-b98d-49e7-a5d5-907852d8d5a2 Hungary | |
| c1ded529-6f2a-418a-ba98-5aa505c95405 Germany | |
| d9fb2df6-ef0c-4e5a-9242-666eda0bd457 Germany | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644578336 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 558 mm |
| Product Net Height | 461 mm |
| Product Net Depth / Length | 396.5 mm |
| Product Net Weight | 81 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 785 mm |
| Package Level 1 Gross Weight | 96 kg |
| Package Level 1 EAN | 8015644578336 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 7000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 4P |
| Power Loss | 350 W |
| Rated Current (In) | 2500 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 2500 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 85 kA | |
| (400 V AC) 85 kA | |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 85 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 75 kA |
| for 3 s 65 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 100 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Uninterrupted Current (Iu) | 2500 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR122/P-LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E3 |
| Terminal Connection Type | Withdrawable Circuit-Breakers |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0015 |
| Instructions and Manuals | 1SDH000460R0002 |
| 1SDH000460R0102 | |
| External Classifications and Standards | |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| Title: | Size: | Type: |
|---|---|---|
| PDF CIRCUIT BREAKERS TMAX XT.pdf | 26 Mbytes |
|
| 1SDA056493R1 1SDA056493R1 EN_1SDA056493R1.pdf | 110 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.