Product successfully added to your shopping cart
1SDA056333R1
ABB
1
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Service Breakers
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | 9b629aae-bfa3-4842-bc6f-c17e1225b7ff Italy |
| Simplified SCIP | 967495d8-68fa-4179-91e8-e07840963a77 Belgium |
| b0ddabd8-546e-4e7e-a062-257a8936ed49 Denmark | |
| 3dc11ec8-226e-4da9-81c3-b62817ed5945 Germany | |
| 5ca325c5-612f-4a28-ab90-ffe2ed4ab586 Belgium | |
| 7ac4cd6e-5933-4adb-8329-1d2d054f27cb Finland | |
| dab875b0-8d55-44a8-91e7-110a244c76f1 Poland | |
| 19704301-5db5-41e6-a344-69036ef83757 Norway | |
| d6f5cb92-7227-47f8-90d4-c104ac492bae Germany | |
| 58257cb8-6d26-4601-aae6-db9b9fc262ad France | |
| f8c1a978-daf3-422a-b178-bf43c8b34002 Sweden | |
| dc6ecf17-6076-4758-98b4-be060784fbe6 Bulgaria | |
| 231ba34b-a58b-4387-a2fe-9f7048f5262d Poland | |
| de99c18d-f4d2-44a3-9382-6210f297db36 Greece | |
| c19fe6ee-5fc1-462d-834e-3d17474663ce Portugal | |
| f4db5893-5fa3-47fc-8721-507f74b94989 Hungary | |
| 9ca1e65c-86bb-460c-afc7-94acb05df360 Estonia | |
| c021265f-43b4-4384-b03c-aea34a88002d Germany | |
| 978bb388-feb1-479c-aa1c-ef2f5d991da6 Croatia | |
| 39d7048b-bdf8-43a2-911f-d92a047cd3ed Poland | |
| 2a3b9bbf-cd3b-4b3e-9b99-826e42a0d481 Czech Republic | |
| 2996857f-f96f-4a42-acd0-5e1fdb7a19a6 Netherlands | |
| eeeb1b8d-dc82-4039-9e8c-292363e59afb Spain | |
| f3f90aee-ff21-4ca8-823c-ff2bd38173ba France | |
| 044f3e38-7516-471b-a05b-a355cc36176f Germany | |
| 0bb54701-46b2-4ea9-b4c0-0b1e4496f656 Sweden | |
| 828436f9-fb54-4c19-94df-67acc3dd4f60 Germany | |
| 955cf9bf-bc41-4342-a9cd-1862e3e0becb Hungary | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644576738 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 558 mm |
| Product Net Height | 461 mm |
| Product Net Depth / Length | 396.5 mm |
| Product Net Weight | 81 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 785 mm |
| Package Level 1 Gross Weight | 96 kg |
| Package Level 1 EAN | 8015644576738 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 6000 cycle |
| Ue = 500 ... 690 V 5000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 4P |
| Power Loss | 570 W |
| Rated Current (In) | 3200 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 3200 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 75 kA |
| (230 V AC) 75 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 75 kA | |
| (500 V AC) 75 kA | |
| (660 V AC) 75 kA | |
| (690 V AC) 75 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 75 kA |
| for 3 s 65 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 75 kA |
| (230 V AC) 75 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 75 kA | |
| (500 V AC) 75 kA | |
| (660 V AC) 75 kA | |
| (690 V AC) 75 kA | |
| Rated Uninterrupted Current (Iu) | 3200 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR122/P-LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E3 |
| Terminal Connection Type | Withdrawable Circuit-Breakers |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0015 |
| Instructions and Manuals | 1SDH000460R0002 |
| 1SDH000460R0102 | |
| External Classifications and Standards | |
| Object Classification Code | Q |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| Title: | Size: | Type: |
|---|---|---|
| PDF CIRCUIT BREAKERS TMAX XT.pdf | 26 Mbytes |
|
| 1SDA056333R1 1SDA056333R1 EN_1SDA056333R1.pdf | 109 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.