| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | 4e72ae7d-03c3-4134-9a5f-725980b9a269 Italy |
| Simplified SCIP | 05beb920-2cd6-4156-bad0-5c866d7bc869 Poland |
| 025047e7-ccdc-4e4c-9946-a4c634cb18a1 Sweden | |
| 767ae571-1eb5-4508-b23e-25570dacf32f Belgium | |
| ab5e09fb-a152-452b-8e7a-137834691ce8 Spain | |
| 506df608-83b0-474b-9b14-fbbee1ba0c41 Hungary | |
| 33608d10-4bf5-4053-a493-c2d876b931e7 France | |
| 64af181d-3e0e-45b8-8a20-4478ff9c823a Germany | |
| b2caaeb6-6cdc-4335-90b7-8c0890af0aae Germany | |
| be3f1653-3d44-472a-9bad-d6cb7379a8f9 France | |
| 12e3d11b-822b-4f08-99bd-b50a779be5da Poland | |
| f1052a1d-af68-4792-88d0-e553b72fcc71 Germany | |
| 8053a185-451f-401d-a973-033c6db898af Belgium | |
| 226403a0-9881-420b-abf4-a96670ebeddf Germany | |
| 37ba76a9-0cc9-49b8-b355-7610d2ec4d77 Norway | |
| a7b4bb18-9fea-4017-97b6-e50e5de01d97 Finland | |
| 100c3dde-065f-4a2f-97d7-5825163e41e7 Portugal | |
| 75734461-c87c-4d14-bb4f-be4212ba880a Greece | |
| fa41a3f0-2e82-41f1-9d8f-afb9d027687d Hungary | |
| 9e196391-4de8-4395-9ca4-8243d3180db5 Poland | |
| 5f571580-c8c5-4935-82af-9e718a346199 Netherlands | |
| 00227e26-41af-46d2-be6f-086fe2382134 Estonia | |
| b28e6d7e-635d-419f-af5e-fb92c0c06180 Germany | |
| d531921b-09a5-431c-8493-d8444a34bbe5 Croatia | |
| b87639bb-5660-46b1-9e20-7441f6071769 Denmark | |
| 6cb73911-67ba-4109-b9ce-e0d4e4c6848e Czech Republic | |
| 71cfd8ab-54f5-4128-9ba1-ff0ad59060c0 Sweden | |
| 7ed96634-25fa-47ef-9576-e0c053ef505a Bulgaria | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644574970 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 530 mm |
| Product Net Height | 418 mm |
| Product Net Depth / Length | 302 mm |
| Product Net Weight | 76 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 785 mm |
| Package Level 1 Gross Weight | 90 kg |
| Package Level 1 EAN | 8015644574970 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 6000 cycle |
| Ue = 500 ... 690 V 5000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 4P |
| Power Loss | 330 W |
| Rated Current (In) | 3200 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 3200 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (380 V AC) 65 kA | |
| (400 V AC) 65 kA | |
| (415 V AC) 65 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 65 kA | |
| (660 V AC) 65 kA | |
| (690 V AC) 65 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 65 kA |
| for 3 s 65 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (380 V AC) 65 kA | |
| (400 V AC) 65 kA | |
| (415 V AC) 65 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 65 kA | |
| (660 V AC) 65 kA | |
| (690 V AC) 65 kA | |
| Rated Uninterrupted Current (Iu) | 3200 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR122/P-LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E3 |
| Terminal Connection Type | Fixed Circuit-Breakers |
| Rear flat Horizontal | |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0015 |
| Instructions and Manuals | 1SDH000460R0002 |
| 1SDH000460R0102 | |
| External Classifications and Standards | |
| Object Classification Code | Q |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| Title: | Size: | Type: |
|---|---|---|
| PDF CIRCUIT BREAKERS TMAX XT.pdf | 26 Mbytes |
|
| 1SDA056157R1 1SDA056157R1 EN_1SDA056157R1.pdf | 93 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.