Product successfully added to your shopping cart
1SDA056037R1
ABB
1
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Service Breakers
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | 9ec7b653-fa94-4ee1-99de-1c18e3c970e9 Italy |
| Simplified SCIP | df1ad451-fb9d-43ad-9c4c-a876d9d59538 Bulgaria |
| 891b364a-cf6b-4b53-be77-985c8648b9ab Poland | |
| d16c60e8-ca04-486b-afc4-ffc0ca8da7a8 Poland | |
| 41651799-f662-46ea-b2e9-c8aceac5a00b Belgium | |
| e13eb056-6479-4757-8841-297cc7eeda50 Czech Republic | |
| 36acbcfc-64c0-4313-a22c-18a078245fad Croatia | |
| 42d65e0e-5ed3-4288-9600-04847de416bd Germany | |
| 4e77fe99-ed19-423e-9fc9-ca125cd48070 Germany | |
| 882ec33a-2ee9-42dc-9aa2-7efaa112ca75 Denmark | |
| e3b308be-0cb1-4283-bc6a-e9f0ab747f2e Hungary | |
| a6add2fd-b9c8-49e4-a3bd-a39280943d0b Netherlands | |
| 14fbba29-32be-4dfd-a90c-ff5a9ff99529 Poland | |
| eb2cf404-51db-4960-a70c-7591a8293dbb Finland | |
| 84c13d9f-3ca2-470a-b442-a806d2f9a401 Norway | |
| 6b495562-6b28-4332-b378-379a3fdf5179 Greece | |
| 823691e7-506f-4547-96a6-033ee332cbca Portugal | |
| 45135e75-468e-4f40-a281-2b5743c67164 Estonia | |
| f5de8da6-3c15-4c32-9a4e-c673c3269060 Sweden | |
| 0e43fab9-ef2f-4360-ad10-e9b7d595d866 Belgium | |
| 517b2d1a-0d3e-4dcc-b7ad-29e094cf0e87 Hungary | |
| 38889ce1-4b5e-46d1-a29d-fe08ccbd1461 Germany | |
| 7f512b78-3df4-4977-ae4d-1c7bdb56f517 Sweden | |
| 97e2a60a-54e5-4c9a-bef0-dd19a062d09d Germany | |
| 695a5c97-12b7-42e6-8ea5-0b5798ae7251 Spain | |
| a9f06a91-ce1a-4fe8-98ab-66e88bd36d1a France | |
| 36660af0-b791-4f3b-b48b-6ecd5286a082 France | |
| 6b20f957-02c5-4d1d-b78e-628e8c1443c3 Germany | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644573775 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 324 mm |
| Product Net Height | 461 mm |
| Product Net Depth / Length | 396.5 mm |
| Product Net Weight | 49 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 59 kg |
| Package Level 1 EAN | 8015644573775 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 10000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 330 W |
| Rated Current (In) | 2000 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 2000 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 85 kA | |
| (400 V AC) 85 kA | |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 65 kA | |
| (660 V AC) 65 kA | |
| (690 V AC) 65 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 65 kA |
| for 3 s 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 85 kA | |
| (400 V AC) 85 kA | |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 65 kA | |
| (660 V AC) 65 kA | |
| (690 V AC) 65 kA | |
| Rated Uninterrupted Current (Iu) | 2000 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR122/P-LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E2 |
| Terminal Connection Type | Withdrawable Circuit-Breakers |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0014 |
| Instructions and Manuals | 1SDH000460R0002 |
| 1SDH000460R0102 | |
| External Classifications and Standards | |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Title: | Size: | Type: |
|---|---|---|
| PDF CIRCUIT BREAKERS TMAX XT.pdf | 26 Mbytes |
|
| 1SDA056037R1 1SDA056037R1 EN_1SDA056037R1.pdf | 107 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.