1SBL931074R8110 ABB AX25-30-10-81 24V50/60Hz View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SBL931074R8110 ABB AX25-30-10-81 24V50/60Hz

1SBL931074R8110

ABB

AX25-30-10-81 24V50/60Hz

AX25-30-10-81 24V 50/60Hz Contactor

More details


Low-voltage industrial components > Power contactor, AC switching

Contactors and overload relays

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
EPLAN Data9AAC177927_EPLAN
Data Sheet, Technical Information1SBC100187L0203
Instructions and Manuals9AKK107492A7057
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width44 mm
Product Net Depth / Length74 mm
Product Net Height76.3 mm
Product Net Weight0.326 kg
Technical
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC0
Rated Operational VoltageAuxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 32 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)(220 / 240 V) 55 °C 27 A
(690 V) 40 °C 32 A
(690 V) 70 °C 23 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 25 A
(440 V) 55 °C 16 A
(500 V) 55 °C 14 A
(690 V) 55 °C 10 A
(380 / 400 V) 55 °C 25 A
(220 / 230 / 240 V) 55 °C 25 A
Rated Operational Current AC-15 (Ie)(500 V) NC 2
(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A
(400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)(24 V) 6 A / 144 W
(110 V) 1.1 A / 121 W
(125 V) 1.1 A / 138 W
(220 V) 0.55 A / 121 W
(250 V) 0.55 A / 138 W
(400 V) 2.8 A / 134 W
(500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)(415 V) 11 kW
(440 V) 9 kW
(500 V) 9 kW
(690 V) 9 kW
(380 / 400 V) 11 kW
(220 / 230 / 240 V) 6.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 32 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 85 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 105 A
for 0.1 s 140 A
for 1 s 100 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 24 V
60 Hz 24 V
Power Lossat Rated Operating Conditions AC-1 per Pole 1.2 W
at Rated Operating Conditions AC-3 per Pole 0.35 W
Operate TimeBetween Coil De-energization and NC Contact Closing 9 ... 16 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NC Contact Opening 7 ... 21 ms
Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening TorqueAuxiliary Circuit 1 N·m
Control Circuit 1 N·m
Main Circuit 1.2 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor
Technical UL/CSA
General Use Rating UL/CSA(600 V AC) 30 A
Horsepower Rating UL/CSA(120 V AC) Single Phase 2 hp
(200 ... 208 V AC) Three Phase 7.5 hp
(220 ... 240 V AC) Three Phase 7.5 hp
(240 V AC) Single Phase 3 hp
(440 ... 480 V AC) Three Phase 15 hp
(550 ... 600 V AC) Three Phase 15 hp
Tightening Torque UL/CSAAuxiliary Circuit 9 in·lb
Control Circuit 9 in·lb
Main Circuit 11 in·lb
Full Load Amps Motor Use(120 V AC) Single Phase 24 A
(200 ... 208 V AC) Three Phase 25.3 A
(220 ... 240 V AC) Three Phase 22 A
(240 V AC) Single Phase 17 A
(440 ... 480 V AC) Three Phase 21 A
(550 ... 600 V AC) Three Phase 17 A
Environmental
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstandaccording to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP169ab428-19ae-470c-8a6e-e7cbeaeff0dd Bulgaria
Simplified SCIP02f1baba-f87e-40db-9496-124a3acfe83d Denmark
0453fb03-634f-4eb6-a661-51d7f627e1da Greece
1bbf0537-03a1-4075-9767-e4a9b4e79694 Finland
31a8d9ed-6ce3-4956-9b48-4d5e80388992 Sweden
469f7451-7375-44d3-bf84-1fb303d53732 France
49dad115-3e1a-4d92-a39c-57e9b1181de0 Estonia
599eed60-de2c-4d62-9a8d-f1fa1943c7f5 Belgium
60e083de-a28b-4c3b-88c5-86635da35546 Spain
64468e69-e690-4393-8e2a-4af863fac0df Hungary
67487805-5070-4d64-be0b-edc066c57910 Czech Republic
848d8189-75b4-4df4-aad4-e3273b9a216c Norway
8bb7e1fe-f33a-4ce7-8ba7-9e93821b312f Germany
b35c3f4c-492a-453b-9649-e7bad5980ab6 Croatia
d59f143b-0bc3-4636-8e37-952f6262595f Netherlands
e2fb786c-4c29-4915-87eb-91c23a8d9a8e Portugal
e8de6085-4049-4d61-b9d1-59fcbc190b3e Italy
ee848b5f-dac6-4ed5-be4c-daf89016ec7e Poland
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
CB Certificate9AKK107492A7072
CCC Certificate9AKK107492A7089
CCS CertificateGZ23PTB00147
CQC CertificateCQC2013010304646608
Declaration of Conformity - CCC2020980304001066
Declaration of Conformity - CE1SBD250011U1000
UL CertificateUL_20140702-E312527-10-5
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width48 mm
Package Level 1 Depth / Length78 mm
Package Level 1 Height79 mm
Package Level 1 Gross Weight0.34 kg
Package Level 1 EAN3471522397812
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors
E-Number (Finland)3707336

ETIM for 1SBL931074R8110 Low-voltage industrial controls and switchgear (EC000066)
Feature Name Feature Value
Rated control supply voltage AC 50 Hz (EF003978) 24 V
Rated control supply voltage AC 60 Hz (EF003979) 24 V
Voltage type for actuating (EF008242) AC
Rated operation current Ie at AC-1, 400 V (EF001393) 32 A
Rated operation current Ie at AC-3, 400 V (EF001392) 25 A
Rated operation power at AC-3, 400 V (EF001364) 11 kW
Modular version (EF001126) No
Number of auxiliary contacts as normally open contact (EF001376) 1
Number of auxiliary contacts as normally closed contact (EF001377) 0
Type of electrical connection of main circuit (EF006819) Screw connection
Number of normally closed contacts as main contact (EF001375) 0
Number of normally open contacts as main contact (EF001374) 3

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE MOTOR PROTECTION EN.pdf 240 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.