ANUNCIAR
1SBL361001R8111 ABB AFC52-30-11-81 24V 50/60Hz View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SBL361001R8111 ABB AFC52-30-11-81 24V 50/60Hz

1SBL361001R8111

ABB

AFC52-30-11-81 24V 50/60Hz

AFC52-30-11-81 24V 50/60Hz Contactor

More details


Low-voltage industrial components > Power contactor, AC switching

Contactors and overload relays

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $251.75
Unit price: $251.75
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information1SBC100219C0201
Instructions and Manuals1SBC101036M6801
Instructions and Manuals (Part 2)1SAC200017M0002
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width67 mm
Product Net Depth / Length119.5 mm
Product Net Height111 mm
Product Net Weight1.02 kg
Technical
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Number of Poles3P
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, UL 60335-2-40 LZGH2 A2L
Rated Operational VoltageMain Circuit 690 V
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 100 A
(690 V) 60 °C 80 A
(690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 53 A
(440 V) 60 °C 53 A
(500 V) 60 °C 45 A
(690 V) 60 °C 35 A
(380 / 400 V) 60 °C 53 A
(220 / 230 / 240 V) 60 °C 53 A
Rated Operational Current AC-3e (Ie)(415 V) 60 °C 53 A
(440 V) 60 °C 53 A
(500 V) 60 °C 45 A
(690 V) 60 °C 35 A
(380 / 400 V) 60 °C 53 A
(220 / 230 / 240 V) 60 °C 53 A
Rated Operational Current AC-15 (Ie)(500 V) NC 2
Rated Operational Current DC-13 (Ie)(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)(415 V) 30 kW
(440 V) 30 kW
(500 V) 30 kW
(690 V) 30 kW
(380 / 400 V) 22 kW
(220 / 230 / 240 V) 15 kW
Rated Operational Power AC-3e (Pe)(415 V) 30 kW
(440 V) 30 kW
(500 V) 30 kW
(690 V) 30 kW
(380 / 400 V) 22 kW
(220 / 230 / 240 V) 15 kW
Rated Operational Power AC-6b (Pe)(400 / 415 V) 40 °C, 50 / 60 Hz 43 kvar
(400 / 415 V) 70 °C, 50 / 60 Hz 39 kvar
(400 / 415 V) 55 °C, 50 / 60 Hz 43 kvar
(440 V) 40 °C, 50 / 60 Hz 41.7 kvar
(440 V) 55 °C, 50 / 60 Hz 41.7 kvar
(440 V) 70 °C, 50 / 60 Hz 37 kvar
(500 / 550 V), 40 °C, 50 / 60 Hz 54 kvar
(500 / 550 V) 55 °C, 50 / 60 Hz 54 kvar
(500 / 550 V) 70 °C, 50 / 60 Hz 48.5 kvar
(690 V) 40 °C, 50 / 60 Hz 74 kvar
(690 V) 55 °C, 50 / 60 Hz 74 kvar
(690 V) 70 °C, 50 / 60 Hz 67 kvar
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
for 0.1 s 140 A
for 1 s 100 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 24 V
60 Hz 24 V
Coil ConsumptionAverage Holding Value 50 / 60 Hz 20 V·A
Average Pull-in Value 50 Hz 150 V·A
Average Pull-in Value 60 Hz 151 V·A
Power Lossat Rated Operating Conditions AC-1 per Pole 6.3 W
at Rated Operating Conditions AC-3 per Pole 1.7 W
Operate TimeBetween Coil De-energization and NC Contact Closing 6 ... 19 ms
Between Coil De-energization and NO Contact Opening 4 ... 14 ms
Between Coil Energization and NC Contact Opening 3 ... 16 ms
Between Coil Energization and NO Contact Closing 7 ... 21 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) 2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid 1/2x 6 ... 3 5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping LengthControl Circuit 10 mm
Main Circuit 16 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw DriverPozidriv PZ
Tightening TorqueAuxiliary Circuit 1.2 N·m
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor
Technical UL/CSA
Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 80 A
Horsepower Rating UL/CSA(120 V AC) Single Phase 3 hp
(200 ... 208 V AC) Three Phase 15 hp
(220 ... 240 V AC) Three Phase 20 hp
(240 V AC) Single Phase 10 hp
(440 ... 480 V AC) Three Phase 40 hp
(550 ... 600 V AC) Three Phase 50 hp
Connecting Capacity Auxiliary Circuit UL/CSARigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSAAuxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Full Load Amps Motor Use(120 V AC) Single Phase 34 A
(200 ... 208 V AC) Three Phase 48.3 A
(220 ... 240 V AC) Three Phase 54 A
(240 V AC) Single Phase 50 A
(440 ... 480 V AC) Three Phase 52 A
(550 ... 600 V AC) Three Phase 52 A
Environmental
Ambient Air TemperatureClose to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Pollution Degree3
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
A2L Certificate – UL9AKK108469A4888
9AKK108469A4889
BV CertificateBV_2634H36994B2
CB CertificateSE-114796
CCC Certificate2020980304001074
CCS CertificateGZ23PTB00147
CQC CertificateCQC2012010304589737
Declaration of Conformity - CE1SBD250024U1000
Declaration of Conformity - UKCA1SBD250045U1000
DNV Certificate9AKK108470A6934
KC Certificate9AKK108471A9560
RINA Certificate9AKK108470A5006
UL CertificateUL-CA-2337651-0
UL-US-2343489-0
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width146.5 mm
Package Level 1 Depth / Length96.5 mm
Package Level 1 Height146.5 mm
Package Level 1 Gross Weight1.14 kg
Package Level 1 EAN3471523018860
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4758 >> Iec Contactors

ETIM for 1SBL361001R8111 Low-voltage industrial controls and switchgear (EC000066)
Feature Name Feature Value
Rated control supply voltage AC 50 Hz (EF003978) 24 V
Rated control supply voltage AC 60 Hz (EF003979) 24 V
Voltage type for actuating (EF008242) AC
Rated operation current Ie at AC-1, 400 V (EF001393) 100 A
Rated operation current Ie at AC-3, 400 V (EF001392) 53 A
Rated operation power at AC-3, 400 V (EF001364) 22 kW
Modular version (EF001126) No
Number of auxiliary contacts as normally open contact (EF001376) 1
Number of auxiliary contacts as normally closed contact (EF001377) 1
Type of electrical connection of main circuit (EF006819) Screw connection
Number of normally closed contacts as main contact (EF001375) 0
Number of normally open contacts as main contact (EF001374) 3

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.