ANUNCIAR
1SBL291501R8000 ABB AFC38-22-00-80 Contactor View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SBL291501R8000 ABB AFC38-22-00-80 Contactor

1SBL291501R8000

ABB

AFC38-22-00-80 Contactor

AFC38-22-00-80 220-230V50Hz 230-240V60Hz Contactor

More details


Low-voltage industrial components > Power contactor, AC switching

Contactors and overload relays

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $252.99
Unit price: $252.99
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information1SBC100219C0201
Instructions and Manuals1SBC101027M6801
Instructions and Manuals (Part 2)1SAC200017M0002
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width45 mm
Product Net Depth / Length101 mm
Product Net Height86 mm
Product Net Weight0.393 kg
Technical
Number of Main Contacts NO2
Number of Main Contacts NC2
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
Number of Poles4P
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1
Rated Operational VoltageMain Circuit 690 V
Rated Frequency (f)Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 55 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 55 A
(690 V) 60 °C 45 A
(690 V) 70 °C 37 A
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 21.2 A
(440 V) 60 °C 20 A
(500 V) 60 °C 17.6 A
(690 V) 60 °C 10.5 A
(380 / 400 V) 60 °C 22 A
(220 / 230 / 240 V) 60 °C 23.2 A
Rated Operational Power AC-3 (Pe)(415 V) 11 kW
(440 V) 11 kW
(500 V) 11 kW
(690 V) 9 kW
(220 / 230 / 240 V) 5.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 55 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 450 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour
(AC-15) 0 cycles per hour
(AC-2 / AC-4) 0 cycles per hour
(AC-3) 0 cycles per hour
(DC-13) 0 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
Coil ConsumptionAverage Holding Value 50 / 60 Hz 8 V·A
Average Pull-in Value 50 Hz 70 V·A
Average Pull-in Value 60 Hz 66 V·A
Power Lossat Rated Operating Conditions AC-1 per Pole 2.3 W
at Rated Operating Conditions AC-3 per Pole 0.42 W
Operate TimeBetween Coil De-energization and NC Contact Closing 9 ... 20 ms
Between Coil De-energization and NO Contact Opening 4 ... 18 ms
Between Coil Energization and NC Contact Opening 7 ... 21 ms
Between Coil Energization and NO Contact Closing 10 ... 26 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) 2 x M4 Screws Placed Diagonally
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 1/2x 1.5 ... 16 mm²
Rigid Solid 1/2x 1.5 ... 4 mm²
Rigid Stranded 1/2x 1.5 ... 16 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping LengthControl Circuit 10 mm
Main Circuit 12 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening TorqueControl Circuit 1.2 N·m
Main Circuit 2.5 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor
Technical UL/CSA
Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 55 A
Connecting Capacity Main Circuit UL/CSARigid Solid 1/2x 16-10 AWG
Rigid Stranded 1/2x 16-6 AWG
Connecting Capacity Control Circuit UL/CSARigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSAControl Circuit 11 in·lb
Main Circuit 22 in·lb
Environmental
Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... 70 °C
Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C
Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Closed, Shock Direction: B1 25 g
Open, Shock Direction: B1 5 g
Resistance to Vibrations4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree3
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
BV CertificateBV_2634H24898C0
CB CertificateCB_SE-116363
CCS CertificateGZ23PTB00147
CQC CertificateCQC2010010304445623
Declaration of Conformity - CCC2020980304001254
Declaration of Conformity - CE1SBD250025U1000
Declaration of Conformity - UKCA1SBD250046U1000
DNV Certificate9AKK108470A6934
RINA Certificate9AKK108470A5006
UL CertificateUL-US-2343502-0
UL-CA-2337663-0
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width87 mm
Package Level 1 Depth / Length103 mm
Package Level 1 Height47 mm
Package Level 1 Gross Weight0.414 kg
Package Level 1 EAN3471523015159
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors

ETIM for 1SBL291501R8000 Low-voltage industrial controls and switchgear (EC000066)
Feature Name Feature Value
Rated control supply voltage AC 50 Hz (EF003978) 220 V
Rated control supply voltage AC 60 Hz (EF003979) 230 V
Voltage type for actuating (EF008242) AC
Rated operation current Ie at AC-1, 400 V (EF001393) 55 A
Rated operation current Ie at AC-3, 400 V (EF001392) 22 A
Modular version (EF001126) No
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as normally closed contact (EF001377) 0
Type of electrical connection of main circuit (EF006819) Screw connection
Number of normally closed contacts as main contact (EF001375) 2
Number of normally open contacts as main contact (EF001374) 2

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE MOTOR PROTECTION EN.pdf 240 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.