ANUNCIAR
1SBH901074R8140 ABB NX40E-81 24V50/60Hz View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SBH901074R8140 ABB NX40E-81 24V50/60Hz

1SBH901074R8140

ABB

NX40E-81 24V50/60Hz

NX40E-81 24V 50/60Hz Contactor relay

More details


Low-voltage industrial components > Contactor relay

Contactors and overload relays

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $23.49
Unit price: $23.49
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
EPLAN Data9AAC178845_EPLAN
Data Sheet, Technical Information1SBC100187L0203
Instructions and ManualsNo
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width44 mm
Product Net Depth / Length74 mm
Product Net Height74 mm
Product Net Weight0.315 kg
Technical
Number of Auxiliary Contacts NO4
Number of Auxiliary Contacts NC0
Rated Operational VoltageAuxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-15 (Ie)(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A
(400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.30 A / 66 W
(250 V) 0.30 A / 75 W
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 140 A
for 1 s 100 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour
(DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency6000 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 24 V
60 Hz 24 V
Operate TimeBetween Coil De-energization and NC Contact Closing 9 ... 16 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NC Contact Opening 7 ... 21 ms
Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Tightening TorqueAuxiliary Circuit 1 N·m
Control Circuit 1 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor Relay
Technical UL/CSA
Tightening Torque UL/CSAAuxiliary Circuit 9 in·lb
Control Circuit 9 in·lb
Environmental
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstandaccording to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Simplified SCIP0d00ff73-1aa6-4004-aec5-b5737d2044f4 France
0fbb0f10-b239-4a16-93b4-f2a367c214bc Netherlands
11d1f9e7-47a2-4dd4-95c1-3449f2739624 Italy
13693866-cb20-4790-81f3-5b91ce105dda Portugal
1c188803-9bd7-4f44-bebb-b70726941a5f Finland
2a32ba97-ff7b-4ca1-8c8f-567793a1a321 Germany
3032a0cd-ecdc-4476-99bb-7689a87fdb85 Hungary
3c8fce87-57f5-4cdf-b235-5aeb378cbdcc Norway
4a2b1798-51cc-4d3d-a5a2-e88cf676cf3b Poland
50414bcb-632b-4993-ab62-b44cca0ec60f Czech Republic
54825340-3ff4-469f-a7c2-737d541aeae2 Estonia
64c487fb-2c4a-430b-8a00-7e505e55a397 Poland
6ce50e27-2515-4f19-b1da-b12e52aff55e Belgium
75c50638-7553-4cc7-8b78-87df9313f776 Denmark
798a2efd-d4ba-4fac-b45d-00a7dc9683ad Germany
7f98b02d-3e46-4036-bd56-da2b20b31714 Greece
8e1ebe81-7196-4e55-a5bc-0ae0f53f040a Hungary
c02a7c6d-bf35-4c06-97f6-94f822fda631 Sweden
c3103a7c-2ac5-4bf0-939b-0680cc421140 Spain
db9d366b-4a81-4712-aa2a-108696fe3f52 France
ef744863-45a4-44d5-a47b-eedce2b8e3f7 Croatia
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
CB Certificate9AKK107492A7071
CCC Certificate9AKK107492A7095
CQC CertificateCQC2013010304653298
Declaration of Conformity - CCC2020980304001057
Declaration of Conformity - CE1SBD250012U1000
UL Certificate9AKK108471A3992
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width48 mm
Package Level 1 Depth / Length78 mm
Package Level 1 Height79 mm
Package Level 1 Gross Weight0.315 kg
Package Level 1 EAN3471522390813
External Classifications and Standards
Object Classification CodeK
ETIM 7EC000196 - Contactor relay
ETIM 8EC000196 - Contactor relay
ETIM 9EC000196 - Contactor relay
eClassV11.0 : 27371001
UNSPSC39121500
IDEA Granular Category Code (IGCC)4755 >> Contactors
E-Number (Finland)3707387

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE MOTOR PROTECTION EN.pdf 240 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.