NL... contactor relays are used for switching auxiliary circuits and control circuits - Poles: 4-pole contactor relays (mechanically linked contact elements available) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available NL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.
Cast iron M2BA and aluminium M3AA motors
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
b'
NL22E 24V DC\n\n
1SBH143001R8122\n\n
3471522292810\n\n
NL22E 24V DC Contactor Relay\n\n
NL... contactor relays are used for switching auxiliary circuits and control circuits - Poles: 4-pole contactor relays (mechanically linked contact elements available) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available NL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.\n\n
1 piece\n\n
85364900\n\n
44 mm\n\n
97 mm\n\n
78 mm\n\n
0.52 kg\n\n
2\n\n
2\n\n
Auxiliary Circuit 690 V\n
Main Circuit 690 V\n\n
Supply Circuit 50 / 60 Hz\n\n
acc. to IEC 60947-5-1, q = 40 °C 16 A\n\n
(500 V) 2 A\n
(690 V) 2 A\n
(24 / 127 V) 6 A\n
(220 / 240 V) 4 A\n
(380 / 400 V) 3 A\n\n
Auxiliary Circuit - gG Type Fuses 10 A\n\n
1200 cycles per hour\n\n
(24 V) 6 / 144 A\n
(48 V) 2.8 / 134 A\n
(72 V) 1 / 72 A\n
(125 V) 0.55 / 69 A\n
(250 V) 0.3 / 75 A\n\n
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V\n
acc. to UL/CSA 600 V\n\n
8 kV\n\n
> 20 million\n\n
6000 cycles per hour\n\n
DC Operation 24 V\n\n
Average Holding Value, from Warm State 3 W\n
Average Pull-in Value, from Cold State 3 W\n\n
Between Coil De-energization and NC Contact Closing 16 ... 27 ms\n
Between Coil De-energization and NO Contact Opening 10 ... 17 ms\n
Between Coil Energization and NC Contact Opening 20 ... 70 ms\n
Between Coil Energization and NO Contact Closing 50 ... 100 ms\n\n
Flexible with Cable End 0.75 ... 2.5 mm²\n
Rigid Cable 1 ... 4 mm²\n\n
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20\n\n
Screw Terminals\n\n
Close to Contactor for Storage -60 ... +80 °C\n
Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... 55 °C\n
Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C\n\n
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II\n\n
Without Derating 3000 m\n\n
Closed, Shock Direction: A 20 g\n
Closed, Shock Direction: B1 15 g\n
Closed, Shock Direction: C1 20 g\n
Closed, Shock Direction: C2 14 g\n
Open, Shock Direction: A 10 g\n
Open, Shock Direction: B1 5 g\n
Open, Shock Direction: C1 8 g\n
Open, Shock Direction: C2 8 g\n
Shock Direction: B2 10 g\n\n
Following EU Directive 2011/65/EU\n\n
1 piece\n\n
86 mm\n\n
141 mm\n\n
51 mm\n\n
0.52 kg\n\n
3471522292810\n\n
box 28 piece\n\n
300 mm\n\n
245 mm\n\n
308 mm\n\n
14.56 kg\n\n
336 piece\n\n
K\n\n
EC000196 - Contactor relay\n\n
EC000196 - Contactor relay\n\n
EC000196 - Contactor relay\n\n
EC000196 - Contactor relay\n\n
V11.0 : 27371018\n\n
39121500\n\n
3709182\n\n
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE LOW VOLTAGE ALUMINUM MOTORS.pdf | 16 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.