ANUNCIAR
1SBE122111R0120 ABB Contact. EN20-20N-01 2NA 24AC/DC View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SBE122111R0120 ABB Contact. EN20-20N-01 2NA 24AC/DC

1SBE122111R0120

ABB

Contact. EN20-20N-01 2NA 24AC/DC

EN20-20N-01 Installation Contactor (NO) 20 A - 2 NO - 0 NC - 24 V - Control Circuit 400 Hz

More details


Devices for distribution board-/surface mounting > Installation contactor for distribution board

Other modular devices

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $111.18
Unit price: $111.18
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85365080
Popular Downloads
EPLAN Data9AAC404714_EPLAN
Data Sheet, Technical Information2CDC103051C0201
Instructions and Manuals2CDC103043M6801
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width18 mm
Product Net Depth / Length65 mm
Product Net Height85 mm
Product Net Weight0.14 kg
Dimension Diagram1SBB505186D3001
Technical
Number of Main Contacts NO2
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
Number of Poles2P
StandardsIEC/EN 60947-1
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC/EN 61095
IEC 60335-2-40 A2L
Rated Operational VoltageMain Circuit 220 V DC
Main Circuit 250 V AC
Rated Frequency (f)Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Rated Operational Current AC-1 (Ie)(NO) 20 A
Rated Operational Current AC-3 (Ie)(230 V) Single Phase, NO 9 A
Rated Operational Current AC-7a (Ie)(NO) 20 A
Rated Operational Current AC-7b (Ie)(230 V) Single Phase, NO 9 A
Rated Operational Power AC-1 (Pe)(230 V) Single Phase 4.6 kW
Rated Operational Power AC-3 (Pe)(230 V) Single Phase 1.3 kW
Rated Operational Power AC-7a (Pe)(230 V) Single Phase 4.6 kW
Rated Operational Power AC-7b (Pe)(230 V) Single Phase 1.3 kW
Rated Breaking Capacity AC-38 x Ie / AC-3
Rated Making Capacity AC-310 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
Rated Insulation Voltage (Ui)400 V
Rated Impulse Withstand Voltage (Uimp)4 kV
Electrical DurabilityAC-1 (NO) 150000 cycle
AC-3 (NO) 150000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 150000 cycle
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Mechanical DurabilityNr. Operations 1000000 cycle
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc)24 V
Coil ConsumptionAverage Holding Value 50 / 60 Hz 2.5 V·A
Average Holding Value DC 2.5 W
Average Pull-in Value 50 Hz 2.5 V·A
Average Pull-in Value 60 Hz 2.5 V·A
Average Pull-in Value DC 2.5 W
Power Lossat Rated Operating Conditions AC-1 per Pole 1.4 W
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main CircuitFlexible with Ferrule 1x 1 ... 6 mm²
Flexible with Ferrule 2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1 ... 6 mm²
Flexible with Insulated Ferrule 2x 1 ... 1.5 mm²
Flexible 1x 1 ... 6 mm²
Flexible 2x 1 ... 4 mm²
Rigid 1x 1 ... 10 mm²
Rigid 2x 1 ... 4 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 2.5 mm²
Flexible 2x 1 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.75 ... 2.5 mm²
Wire Stripping LengthControl Circuit 7 mm
Main Circuit 10 mm
Degree of ProtectionIP20
Recommended Screw DriverControl Circuit Pozidriv 1
Main Circuit Pozidriv 1
Tightening TorqueControl Circuit 0.9 N·m
Main Circuit 1.2 N·m
Terminal TypeScrew Terminals
Width in Number of Modular Spacings1.0
Product NameInstallation Contactor
Environmental
Ambient Air TemperatureOperation -25 ... +55 °C
Storage -40 ... +80 °C
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 15g
Pollution Degree3
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP121b305f-5b90-4c99-9b7d-a1e740b7cdc5 Bulgaria
Simplified SCIP824f56eb-e254-4cfe-b348-970439a81e6f Germany
de2d4324-2d47-4943-9d18-aaaae19f3606 Croatia
793cba64-ad33-4075-bfe4-9837a6613ce1 Czech Republic
a514711b-9c6a-42bd-a5e9-8d08b557858b Poland
5945361d-323b-4f3b-aba4-86be10e1b331 Netherlands
47f85850-ac1b-46e3-80d0-2f0e9ce60107 Denmark
1c5dc924-f46b-4323-9ba0-14ebdb870b4b Germany
df75612b-bd9a-4cf1-8500-8ae9cd01fc18 Finland
b8504cc4-45ba-48c5-8593-2081c24cf11b Belgium
9cbd93d4-b99f-4b02-b7c6-2850da88624e Poland
71dd1f21-27e9-4987-b957-6e1b0856266f Germany
a21fd4cf-c373-438c-88a2-b16db05103b8 Norway
984e06c9-8951-4610-9664-cbbcfb995050 Greece
37b854f9-c24b-43f3-8c55-1af23efa1408 Hungary
bb41b006-6443-4255-bbe9-be909d682ee7 Estonia
5a6194b1-a4a3-411c-a0ef-449d38368433 Belgium
3ed81dca-6dba-419b-9841-19bbba625fa0 France
5769850a-4967-496c-8e1c-a64a076748e9 Hungary
53ec2329-2541-4ad9-a1a0-2cc79fd3ccf5 Germany
af0e7f81-7cac-4063-9197-c6722f2f2e69 Sweden
5d440b28-cf6e-432f-a1a2-c73055562626 Germany
f4a2b9ee-bee0-4c68-9a0d-9db87bc6f237 France
f4a7f6c6-1615-4779-a05f-c1ab8e166c8e Sweden
4989e515-ff2b-4931-8a39-1686fd4f3293 Poland
2f102729-12ab-4bcf-a5d1-2c601d00a547 Spain
2d791a59-d1f3-4779-ac1f-509fa53d2757 Portugal
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Consumer
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
End Of Life Disassembling Instructions1SBC100156C0268
Environmental Product Declaration - EPD1SAC200416H0001
Certificates and Declarations
A2L Certificate – IEC1SAA920000-4601
CB Certificate1SAA920007-2001
CQC CertificateCQC2018010304057353
CQC2018010304057344
Declaration of Conformity - CCC2020980304001370
2020980304001371
Declaration of Conformity - CE1SAD101100-3301
Declaration of Conformity - UKCA1SAD201100-3301
EAC Certificate1SAA920003-2701
NF Certificate1SAA920002-1201
RMRS Certificate1SAA920000-0705
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width88 mm
Package Level 1 Depth / Length20 mm
Package Level 1 Height71 mm
Package Level 1 Gross Weight0.14 kg
Package Level 1 EAN3471523004689
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC001653 - Installation contactor for distribution board
ETIM 8EC001653 - Installation contactor for distribution board
ETIM 9EC001653 - Installation contactor for distribution board
eClassV11.0 : 27142308
UNSPSC39121529
IDEA Granular Category Code (IGCC)4759 >> Installation contactor for distribution board
E-Number (Finland)3707803

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.